• Title/Summary/Keyword: 표면 장력

Search Result 486, Processing Time 0.024 seconds

Comparison of Cleaning Performance of CFC 113 and the Alternatives (CFC 113과 대체세정제의 세정성능 비교)

  • Row, Kyung Ho;Choi, Dai-Ki;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.521-530
    • /
    • 1993
  • According to the Montreal Protocol, CFC 113, one of the ozone-depleting substances, will be prohibited to use as a cleaning solvent essentially in the electronic industry. Therefore, the development of the alternative cleaning solvents to CFC 113 is being accelerated. A number of the alternative cleaning solvents are avialable on the market. The alternatives of Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), and EC-Ultra(Petroferm) are chosen for the comparison of cleaning performance with CFC 113. The test methods for measuring the cleaning performance were composed of the measurement of the physical properties, the experiments on the material compatibility with cleaning solvents, the measurement of the evaporation rate, and finally the experiments of the removal efficiency. Normally the basic physical properties of the alternatives had higher boiling points, viscosity and surface tension, which were quite different to those of CFC 113. In terms of solubility of rosin-based flux, the solubilities of abietic acid (nonpolar organic) were similar, but those of the activator (polar organic) in the alternatives were better than CFC 113. The evaporation of the alternatives was very slow, compared to CFC 113, which had much lower boiling point. All the cleaning solvents showed the good material compatibility with FR4 and Cu-coated PCB. The better removal efficiencies of abietic acid were obtained when using the ultrasonic mechanical energy over the dipping method. The experiments also indicated the very slow-eavaporating solvent was not desirable with the dipping cleaning method, and the differences in the removal efficiency of the alternatives with the ultrasonic cleaning method were negligible. Among the alternatives, the overall cleaning performances were obsorved as almost similar. Before selecting the ultimate cleaning solvent, the application of cleaning machine, environmental issues, and economics are simultaneously considered with the cleaning performance.

  • PDF

The role of the middle term in the integration of the two premises in linear syllogistic reasoning (선형 삼단 논법의 두 전제 통합 과정에서 중간 항목의 역할)

  • 정혜선;조명한
    • Korean Journal of Cognitive Science
    • /
    • v.12 no.3
    • /
    • pp.29-46
    • /
    • 2001
  • This study attempted to demonstrate that the integration of the two premises in linear syllogism is mediated by the middle term the term that is repeated in the two premises. In Experiment 1. we examined whether representing the middle term is more important than representing the end terms. We asked a question to each premise. Depending on the order of the questions either the two end terms or the middle term became the answer in both premises. Participants solved the problems better when the middle term became the answer suggesting that it is more important to represent the middle term than the end terms. In Experiment 2 we examined whether additional processing is needed for the integration beyond establishing co-referential link through the middle term. We pronominalized the middle term in the second premise and provided two kinds of information to disambiguate the pronoun. In the direct information condition we provided information about who the pronoun is whereas in the indirect information condition we provided information about the relative location of the pronoun. Participants solved the problems more quickly in the indirect information condition than in the direct information condition indicating that mere co-referential link was not enough and that the relative location of the middle term needs to be computed for the integration of the two premises.

  • PDF

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

The Effect of Endotoxin on Gene Expression and Total Amount of Surfactant Protein A (내독소가 Surfactant Protein A의 유전자 발현과 총단백량에 미치는 영향에 관한 실험적 연구)

  • Moon, Doo-Seop;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.703-714
    • /
    • 2000
  • Background : Surfactant protein A (SP-A) is important in the regulation of surfactant secretion, synthesis and recycling. SP-A has important roles in regulating surfactant metabolism as well as in determining surfactant's physical properties. Since systemic sepsis is one of the common causes of acute respiratory distress syndrome (ARDS) and abnormalities in surfactant function have been described in ARDS, the authors investigated the effects of endotoxemia on the accumulation of mRNA encoding SP-A and SP-A protein content. Methods : Adult rats were given various doses of intraperitoneal endotoxin from Salmonella enteritidis and sacrificed at different times. SP-A mRNA was measured by filter hybridization method. Lung SP-A protein content was determined by double sandwich ELISA assay using a polyclonal antiserum raised in rabbits against purified rat SP-A. Results : 1) The accumulation of SP-A mRNA in the endotoxin treated group 24 hours after 2mg/kg and 5mg/kg endotoxin treatments was significantly increased 50.9% and 27.3%, respectively, compared to the control group (P<0.001, P<0.025). 2) The accumulation of SP-A mRNA 24 hours in the 5mg/kg endotoxin treated group was significantly increased by 26.5% compared to the control group (P<0.01). 3) Total amount of lung SP-A was not altered at 24 hours by various doses of treatment. Total lung SP-A content 144 hours after endotoxin administration was significantly decreased by 51.4% compared to the control group (P<0.01). Conclusions : The specific regulation of SP-A by various time course in vivo is evident. The late decline in SP-A protein content was unexpected and suggests that SP-A may be differentially regulated during lung inflammation. The functional significance of these alterations remains to be clarified.

  • PDF

Evaluation of Application Possibility for Floating Marine Pollutants Detection Using Image Enhancement Techniques: A Case Study for Thin Oil Film on the Sea Surface (영상 강화 기법을 통한 부유성 해양오염물질 탐지 기술 적용 가능성 평가: 해수면의 얇은 유막을 대상으로)

  • Soyeong Jang;Yeongbin Park;Jaeyeop Kwon;Sangheon Lee;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1353-1369
    • /
    • 2023
  • In the event of a disaster accident at sea, the scale of damage will vary due to weather effects such as wind, currents, and tidal waves, and it is obligatory to minimize the scale of damage by establishing appropriate control plans through quick on-site identification. In particular, it is difficult to identify pollutants that exist in a thin film at sea surface due to their relatively low viscosity and surface tension among pollutants discharged into the sea. Therefore, this study aims to develop an algorithm to detect suspended pollutants on the sea surface in RGB images using imaging equipment that can be easily used in the field, and to evaluate the performance of the algorithm using input data obtained from actual waters. The developed algorithm uses image enhancement techniques to improve the contrast between the intensity values of pollutants and general sea surfaces, and through histogram analysis, the background threshold is found,suspended solids other than pollutants are removed, and finally pollutants are classified. In this study, a real sea test using substitute materials was performed to evaluate the performance of the developed algorithm, and most of the suspended marine pollutants were detected, but the false detection area occurred in places with strong waves. However, the detection results are about three times better than the detection method using a single threshold in the existing algorithm. Through the results of this R&D, it is expected to be useful for on-site control response activities by detecting suspended marine pollutants that were difficult to identify with the naked eye at existing sites.