• Title/Summary/Keyword: 표면초음파

Search Result 534, Processing Time 0.035 seconds

Reproducibility Evaluation of Shear Wave Elastography According to the Depth of the Simulated Lesion in Breast Ultrasonography (유방초음파 검사에서 모조 병소의 깊이에 따른 전단파 탄성초음파의 재현성 평가)

  • Jin-Hee Kim;In-Soo Kim;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.919-927
    • /
    • 2023
  • Elastography utilizes the fact that the tissue of a malignant tumor is harder than that of a benign tumor and increases the specificity of diagnosis according to the elastic modulus of the tumor, helping to reduce unnecessary biopsies. However, the reliability of elastography can be influenced by the equipment used and the examiner's skills. In this study, the researchers analyzed the reproducibility of elastography by evaluating phantom images when measuring the elasticity values repeatedly. Phantoms were created using silicone and gelatin with different levels of stiffness, and they were inserted at varying depths from the surface. The elasticity values were measured using shear wave elastography. The study aimed to determine whether the reproducibility of elasticity values remains consistent depending on the stiffness and depth of the lesions. The experimental results showed that there was no statistically significant correlation between the elasticity values obtained through shear wave elastography and the depth or stiffness of the lesions. However, in the lesions with the lowest stiffness, the elasticity values were statistically significant (p<0.001) and showed a high correlation with the depth of the lesions. Although there were variations in the measured elasticity values based on the differences in lesion stiffness and depth, these differences did not significantly impact the diagnosis. Therefore, shear wave elastography remains a reliable diagnostic method, and it is suggested that it can be helpful in the diagnosis of breast lesions.

Dispersion Characteristics of Silica Nanopowder in Aqueous Solution and Evaluation of Ni Composite Coating (실리카 나노 분말의 용액 내 분산 특성과 니켈 복합 도금에 관한 연구)

  • Park, So-Yeon;Jeong, Myeong-Won;Lee, Heung-Ryeol;Lee, Jae-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.67-67
    • /
    • 2011
  • 퍼멀로이의 내식성, 기계적 성질 등을 증가시키기 위해 복합도금을 실시하였다. 실리카 나노분말의 분산특성을 Zeta potential을 이용하여 측정하였으며 알칼리 도금액에서 퍼멀로이-실리카 복합도금을 실시하였다. 실리카 나노분말의 응집을 최소로 하기 위하여 전극의 RPM 변화, 첨가제와 초음파의 복합처리에 따른 변화, 전류 밀도 변화를 살펴보았다.

  • PDF

Zincate treatment of AZ31 magnesium alloy (AZ31 마그네슘 합금의 징케이트 처리 기술)

  • Gwon, Du-Yeong;Mun, Seong-Mo;Kim, Yong-Tae
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.100-100
    • /
    • 2015
  • 본 연구에서는 AZ31 마그네슘 합금의 징케이트 피막 형성 메커니즘을 용액의 조성에 따라 연구하였고, 징케이팅 공정에서 초음파가 피막의 형성 미 성장에 미치는 영향에 살펴보았다. 또한 AZ31 마그네슘 합금을 징케이트 처리한 후 구리를 도금하여 피막 형성 특성을 살펴보았다.

  • PDF

Ultrasonic Nonlinearity of AISI316 Austenitic Steel Subjected to Long-Term Isothermal Aging (장시간 등온열화된 AISI316 오스테나이트강의 초음파 비선형성)

  • Gong, Won-Sik;Kim, ChungSeok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.241-247
    • /
    • 2014
  • This study presents the ultrasonic nonlinearity of AISI316 austenitic stainless steels subjected to longterm isothermal aging. These steels are attractive materials for use in industrial mechanical structures because of their strength at high-temperatures and their chemical stability. The test materials were subjected to accelerated heat-treatment in an electrical furnace for a predetermined aging duration. The variations in the ultrasonic nonlinearity and microstructural damage were carefully evaluated through observation of the microstructure. The ultrasonic nonlinearity stiffly dropped after aging for up to 1000 h and, then, monotonously decreased. The polygonal shape of the initial grain structures changed to circular, especially as the annealing twins in the grains dissolved and disappeared. The delta ferrite on the grain boundaries could not be observed at 1000 h of aging, and these continuously transformed into their sigma phases. Consequently, in the intial aging period, the rapid decrease in the ultrasonic nonlinearity was caused by voids, dislocations, and twin annihilation. The continuous monotonic decrease in the ultrasonic nonlinearity after the first drop resulted from the generation of $Cr_{23}C_6$ precipitates and ${\sigma}$ phases.

Analysis and Simulation of Ultrasonic Wave Propagation and Scattering in Unidirectional Fiber Composites (단일방향 섬유 복합재료 내의 초음파 전파 및 산란 현상의 해석과 시뮬레이션)

  • Lee, Choon-Jae;Yim, Hyun-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.269-276
    • /
    • 2001
  • Ultrasonic testing of composite materials is much more difficult than that of isotropic materials, because of the beam skew phenomenon caused by their elastic anisotropy. An established analytical method exists for elastic wave propagation in anisotropic media as a result of previous research efforts. Yet, due to the complexity of the analytical method, solution of real problems must resort to the numerical method. In this work, analytical solutions have first been obtained for the wavefield due to a point source in a unidirectional fiber-reinforced composite, which may be modeled as transversely isotropic. Then, the corresponding numerical solutions have been obtained using the mass-spring lattice model(MSLM). The two solutions have agreed well with each other. Other problems such as reflection from free boundaries and scattering from cracks have also been solved numerically, and the results have been investigated from the viewpoint of wave mechanics. The numerical model whose validity has been confirmed by this work will be of great use in simulating ultrasonic testing of composite materials.

  • PDF

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

Haptic Simulation Algorithm for Tooth Scaling Training (치아 스케일링 훈련을 위한 햅틱 시뮬레이션 알고리즘)

  • Cho, Jae-Hyun;Kim, Jai-Hyun;Park, Jin-Ah
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06b
    • /
    • pp.290-293
    • /
    • 2011
  • 치아 스케일링은 치아에 단단하게 결착된 치석을 제거하는 치과 시술로서 치아 우식 및 잇몸염증을 예방하는 중요한 시술이다. 특히 요즘에는 치료시간의 단축을 통한 효율성 증대의 목적으로 전기적 에너지를 미세한 진동에너지로 바꾸는 원리를 활용한 초음파 스케일링 기법이 많이 행해지고 있다. 하지만 치아 및 치석 확보에 따른 어려움으로 인해 스케일링 시술을 충분히 훈련하기란 쉽지 않다. 본 논문에서는 사용자가 가상현실을 통해 시각 및 촉각 피드백을 받으며 초음파 스케일링 시술을 훈련할 수 있는 치아 스케일링 시뮬레이션을 위한 알고리즘을 제안한다. 치아, 치석 및 잇몸의 볼륨모델과 스케이러 팁을 구성하는 각 부문의 관통깊이를 이용한 햅틱 랜더링 기법을 적용하여 스케일러의 모양에 따른 햅틱 피드백을 생성하였다. 그리고 치아의 손상을 줄이기 위해 스케일러의 팁 부문이 치아 표면에 되도록 평형을 이루어야 한다는 점에 입각하여, 치석을 구성하는 복셀들의 치아 디스턴스필드 값 비교를 통해 치석과 치아 사이의 접착면을 추출하고 스케일러의 팁 부분과 충돌하는 추출된 집착면의 각도를 고려한 스케일링 알고리즘을 구현하였다. 또한 수동 스케일링과는 달리 초음파 스케일링은 초음파의 진동에너지에 의해 점진적으로 치아와 치석 사이의 결속력이 감소된다는 점에 착안하여 치아와 치석의 접착면을 구성하는 지점 사이의 거리에 따른 결속력 감쇠 모델을 고안하였다.

Development of an ultrasonic velocity profiler by using pulse repetition frequency method (펄스반복주파수 기법을 이용한 초음파 유속 프로파일러 개발)

  • Lee, Chan-Joo;Kim, Dong-Gu;Kwon, Sung-Il;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1921-1925
    • /
    • 2010
  • 개수로의 흐름을 측정하는 유속계는 유체역학 및 수리학적 연구와 유량 측정 등의 업무에 필수적인 장비이다. 그동안 국내에서는 일부 전자파표면유속계(이상호 등, 1997)와 영상처리 기반의 LSPIV(김영근 등, 2004)와 같은 비접촉식 유속측정 장치가 개발되어 활용되고 있지만, 유속 및 유량 측정에 보다 널리 사용되고 있는 수중 투입식 유속계의 경우 거의 개발되지 않았다. 특히 유속 분포를 측정하는데 활용될 수 있는 초음파 방식 유속 프로파일러는 거의 전적으로 외국제품에 의존하고 있다. 일반 유속계가 점유속을 측정하는데 비해 유속 프로파일러는 센서가 지향하는 방향선을 따라 공간적인 유속분포를 동시에 획득할 수 있으므로 측정 효율성이 높다는 장점을 지닌다. 본 연구에서는 국내 기술로 개수로 흐름 측정에 활용할 수 있는 초음파 유속 프로파일러를 개발하였다. 이 유속 프로파일러는 초음파 펄스를 반복적으로 송수신하는 PRF 기법을 이용하여 개발하였다. 개발된 유속 프로파일러는 직사각형 수로에서 유속 분포를 측정하기 위해 적용하였으며, 기존의 2차원 유속계와 그 결과를 비교하였다. 본 연구에서 개발한 유속 프로파일러는 실제 하천에 활용하기에는 측정 가능한 유속 및 수심 범위의 한계가 있으나 PRF 기법의 한계 범위에서는 실측 유속분포를 비교적 잘 재현하는 것으로 나타났다.

  • PDF

A Study on the Atomization Characteristics of the Ultrasonic-Energy-Irradiation High Viscosity Biodiesel Blended Fuel (초음파 에너지 조사 고 점도 바이오디젤 혼합연료의 미립화 특성에 관한 연구)

  • Song Yong-Seek;Yang In-Kwon;Kim Bong-Seock;Ryu Jung-In
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.235-241
    • /
    • 2004
  • This experiment was undertaken to investigate the atomization characteristics of the high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Test fuels were conventional diesel fuel and biodiesel one. We compared to the characteristics of viscosity and surface tension, SMD between high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Sauter mean diameter was measured under the variation of the spray distance. Viscosity and surface tension were measured under the variation of the time trace. To measure the droplet size, we used the Malvern system 2600c. Droplet size distribution was analyzed from the result data of Malvern system. Through this experiment, we found that the condition of the ultrasonic energy irradiation situation had smaller Sauter mean diameter of droplet, viscosity and surface tension than those of the conventional situation.

MWCNT 및 무기 바인더를 사용하여 103Ω/cm2이하의 낮은 표면저항과 접촉각 160° 이상의 초발수성을 갖는 코팅액 개발

  • Kim, Ju-Yeong;Lee, Jun-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.94-94
    • /
    • 2018
  • 무인자동차 및 전기자동차 등 전장부품 및 메인보드에서의 오염 방지와 전자파에 의한 신호 간섭 현상에 따른 기기의 오작동을 방지하고자 MWCNT의 clustering 및 tangling현상을 활용하여 self cleaning 기능을 갖는 super hydrophobic 표면과 high aspect ratio에 의한 percolation 현상을 활용하여 전자파 차폐를 위한 낮은 표면저항을 만족하는 복합 재료로 구성된 코팅에 관하여 연구하였다. 이를 위해 isopropyl alcohol(IPA)을 용매로 산처리 한 MWCNT와 무기바인더, 불소계 실란을 첨가하여 초음파 분산을 함으로써 코팅액을 제조하였다. 이를 full cone nozzle type, 흡상식 스프레이 조건으로 알루미늄 시편위에 스프레이 코팅 후 열경화 하여 접촉각측정기로 측정 결과 $160^{\circ}$이상의 초발수 표면과 Low Resistivity Meter로 표면저항을 측정한 결과 $10^3{\Omega}/cm^2$ 이하의 낮은 코팅막을 구현하였으며 내구성 실험을 위한 항온항습 장비로 $80^{\circ}C$의 내열테스트 및 80%와 $80^{\circ}C$조건하에서의 내습테스트 결과 표면에 이상 없음을 확인하였고 열전도율 측정을 위해 밀도 측정 결과 $2.68g/cm^3$, 비열 측정 결과 $0.85J/g^{\circ}C$가 열확산율 측정결과 $88.64mm^2/s$가 측정 되었으며 밀도, 비열, 열확산율을 곱한 값인 $201.9W/m{\cdot}K$의 열전도를 갖는 코팅막을 구현하였다.

  • PDF