Heat Transfer and Pressure Drop Characteristics of Heat Exchangers Having Plain Fins Under Dry and Wet Conditions (평판휜 열 교환기의 건표면, 습표면 열전달 및 압력손실에 관한 연구)

  • 민창근;조진표;오왕규;김내현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.218-229
    • /
    • 2004
  • In this study, dry and wet surface pressure drop and heat transfer characteristics of heat exchangers having plain fins were investigated. Nine samples having different fin pitches and rows were tested. The wet surface heat transfer coefficient was reduced from experimental data using enthalpy-potential method. The wet surface heat transfer coefficients were approximately equal to the dry surface values except for one row configuration. For one row configuration, the wet surface heat transfer coefficients were approximately 30% lower than the dry surface values. For the pressure drop, the wet surface yielded approximately 30% higher values compared with the dry surface counterpart. Data were compared with existing correlations.

A study on humidity sensor using ZnO nanowires (ZnO 나노와이어 구조체를 이용한 습도 센서 연구)

  • Park, Su-Bin;Gwak, Byeong-Gwan;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.48-48
    • /
    • 2018
  • 습도는 대기중에 분포되어있는 물 분자의 양으로 사람이 살아가는데 있어 막대한 영향을 주는 환경적 요소중 하나이다. 산업적 가스의 순도에 막대한 영향을 끼치기도 하고, 반도체 산업에서 불량률과도 밀접한 관련이 있다. 또한, 식품학이나 기상학, 농사와도 밀접한 관련이 있어서 습도를 측정하는 것은 중요시 되고 있다. 이를 위해서 많은 물질들이 사용되고, 연구되었다. 산화 구리, 산화 아연, 산화 납 등의 산화금속 물질들이나 전도성 고분자, 실리콘 기반의 물질들이 주로 사용되고 있는데, 그 중 산화 금속이 쉬운 합성 방법과 낮은 단가, 명확한 작동 원리로 인해 널리 사용되고 있다. 산화 아연의 경우 넓은 direct band gap energy와 우수한 내화학성으로 인해 주로 사용되는데 그 중 1차원 물질인 nanowire의 경우 비등성 구조와 높은 비표면적을 갖는 특성으로 인해 산화 아연의 nanowire 구조가 많이 사용된다. 본 연구에서는 열처리 공정을 이용하여 산화아연의 nanowire 구조를 합성하였고, 합성된 nanowire는 양쪽의 미세전극을 직접적으로 연결하여 간편한 방식으로 소형 소자를 만들 수 있다는 장점이 있다. 열처리 공정 이전에 전기도금 방식을 이용하여 아연층을 증착 하였다. 전기도금 조건은 0.1 M의 염화 아연과 1 M의 염화 칼륨으로 구성된 용액에 -1.1 V를 인가하였다. 합성된 아연층은 열처리 공정에 의해 산화아연의 nanowire 구조체로 변환되고, SEM (scanning electron microscope)를 통해 표면 형상을 관찰 하였고, XRD (X-ray diffraction)을 통해 미세구조를 확인하였다. -1 V부터 1 V 범위의 전압을 흘려주어 형성된 소자의 전기적 특성을 확인하였고, 1 V를 인가하였을 때, 습도 변화에 따른 센서 소자의 저항변화를 통해 습도 센서로서의 특성을 확인 하였다.

  • PDF

Relation between Autogenous Shrinkage of Concrete and Relative Humidity, Capillary Pressure, Surface Energy in Pore (공극 내 상대습도, 모세관압력, 표면에너지 변화에 따른 콘크리트 자기수축)

  • Lee, Chang-Soo;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.131-138
    • /
    • 2008
  • Humidity and strain were estimated for understanding the relation between humidity change by self-desiccation and shrinkage in high-performance concrete with low water binder ratio. Internal humidity change and shrinkage strain were about 10%, 4% and $320\times10^{-6}$, $120\times10^{-6}$ respectively on concrete with water binder ratio 0.3, 0.4 and from the results, humidity change and shrinkage represented the strong linear relation regardless of mixture. For specifying the relation on internal humidity change and autogenous shrinkage strain, shrinkage model was established which is driven by capillary pressure in pore water and surface energy in hydrates on the assumption of a single network and extended meniscus in pore system of concrete. This model and experimental results had a similar tendency so it would be concluded that the internal humidity change by self-desiccation in HPC originated in small pores less than 20 nm, therefore controlling plan on autogenous shrinkage might be focused on surface tension of water and degree of saturation in small pore.

In Vitro Evaluation of Microleakage and Penetration of Hydrophilic Sealants Applied on Dry and Moist Enamel (법랑질 수분 처리에 따른 친수성 치면열구전색제의 미세누출과 열구 침투도 평가)

  • Ku, Jaewon;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.272-279
    • /
    • 2017
  • This study aimed to evaluate the microleakage and penetration of two hydrophilic sealants, Embrace $Wetbond^{TM}$ and Ultraseal $XT^{(R)}$ $hydro^{TM}$, when applied on dry and moist enamel, as compared to a conventionally used hydrophobic sealant, $Clinpro^{TM}$. A total of 60 sound human third molars were randomly divided into 5 groups according to the enamel moisture control and the sealant material used. After sealant application, the teeth were thermocycled and immersed in 1% methylene blue dye. Subsequently, the teeth were sectioned twice and the sections were examined using an optical microscope and image analysis software. Application of Embrace $Wetbond^{TM}$ on either dry or moist enamel resulted in more microleakage than $Clinpro^{TM}$. Application of Ultraseal $XT^{(R)}$ $hydro^{TM}$ on dry enamel showed a similar level of microleakage to $Clinpro^{TM}$, but application on moist enamel resulted in more microleakage. There were no significant differences between the groups in penetration. In conclusion, application of hydrophilic sealants on moist enamel did not improve the sealing ability and showed lower sealing ability than that of $Clinpro^{TM}$ applied on dry enamel.

Wet Surface Performance Test of PF Heat Exchanger (PF열교환기의 습표면 성능시험)

  • Cho, J.P.;Kim, N.H.;Choi, K.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.314-320
    • /
    • 2000
  • In this study, the wet surface heat transfer coefficients and friction factors of PF heat exchangers are presented. Two sample with different fin pitch(1.25mm, 1.5mm) were tested. Tests were conducted in a open loop wind tunnel. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 410-81. Results showed that the heat transfer coefficients of the heat exchanger with 1.5mm fin pitch were approximately the same as those with 1.25mm fin pitch, except at low reynolds number(Re<100), where the heat transfer coefficients of 1.5mm fin pitch were slighly higher than those with 1.25mm fin pitch. The friction factors of the 1.25mm fin pitch, however was 120 % to 160 % higher than those of the 1.5mm fin pitch. The wet surface heat transfer coefficients were lower than those of the dry surface. The wet surface friction factors, however, were higher than those of the dry surface.

  • PDF

A study on sagging failures of water-borne corrosion-protective marine coatings (선박용 중방식 수용성 도료의 sagging 결함 원인에 관한 연구)

  • Kim, Jin-Eok;Cheon, Je-Il;Han, Myeong-Su;U, Jong-Sik
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.80-81
    • /
    • 2014
  • 환경보호 정책에 대응하고 보건 및 안전의 수준 향상을 위한 수용성 도료의 적용 시, 일부 도장 공정에서 도막 건조의 지연으로 sagging 현상이 발생하였다. 이러한 sagging 현상이 일어난 원인을 실험을 통해 분석한 결과, 도료가 갖는 고유의 yield stress와 더불어 습도 및 통기 상태 등의 시공 환경이 지배적인 영향을 미친다고 파악되었다. Sagging 현상의 재발을 방지하기 위해서는 높은 sagging 저항성을 갖는 도료의 선정뿐만 아니라 도장 공장의 적절한 온/습도 및 환기 제어가 선행되어야 한다.

  • PDF

In-Situ Performance Test of a Wet Surface Finned-Tube Evaporator of an Air Source Heat Pump (공랭식 열펌프의 습표면 핀-관 증발기의 현장 성능 시험)

  • 백영진;장영수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.818-826
    • /
    • 2001
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist, From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. since current procedure underpredicted the experimental sensible heat factor(SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test in necessary.

  • PDF

Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions (습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성)

  • Chang, Keun-Sun;Phan, Thanh-Long
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.