평판휜 열 교환기의 건표면, 습표면 열전달 및 압력손실에 관한 연구 (Heat Transfer and Pressure Drop Characteristics of Heat Exchangers Having Plain Fins Under Dry and Wet Conditions)

  • 민창근;조진표;오왕규;김내현
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.218-229
    • /
    • 2004
  • In this study, dry and wet surface pressure drop and heat transfer characteristics of heat exchangers having plain fins were investigated. Nine samples having different fin pitches and rows were tested. The wet surface heat transfer coefficient was reduced from experimental data using enthalpy-potential method. The wet surface heat transfer coefficients were approximately equal to the dry surface values except for one row configuration. For one row configuration, the wet surface heat transfer coefficients were approximately 30% lower than the dry surface values. For the pressure drop, the wet surface yielded approximately 30% higher values compared with the dry surface counterpart. Data were compared with existing correlations.

ZnO 나노와이어 구조체를 이용한 습도 센서 연구 (A study on humidity sensor using ZnO nanowires)

  • 박수빈;곽병관;유봉영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.48-48
    • /
    • 2018
  • 습도는 대기중에 분포되어있는 물 분자의 양으로 사람이 살아가는데 있어 막대한 영향을 주는 환경적 요소중 하나이다. 산업적 가스의 순도에 막대한 영향을 끼치기도 하고, 반도체 산업에서 불량률과도 밀접한 관련이 있다. 또한, 식품학이나 기상학, 농사와도 밀접한 관련이 있어서 습도를 측정하는 것은 중요시 되고 있다. 이를 위해서 많은 물질들이 사용되고, 연구되었다. 산화 구리, 산화 아연, 산화 납 등의 산화금속 물질들이나 전도성 고분자, 실리콘 기반의 물질들이 주로 사용되고 있는데, 그 중 산화 금속이 쉬운 합성 방법과 낮은 단가, 명확한 작동 원리로 인해 널리 사용되고 있다. 산화 아연의 경우 넓은 direct band gap energy와 우수한 내화학성으로 인해 주로 사용되는데 그 중 1차원 물질인 nanowire의 경우 비등성 구조와 높은 비표면적을 갖는 특성으로 인해 산화 아연의 nanowire 구조가 많이 사용된다. 본 연구에서는 열처리 공정을 이용하여 산화아연의 nanowire 구조를 합성하였고, 합성된 nanowire는 양쪽의 미세전극을 직접적으로 연결하여 간편한 방식으로 소형 소자를 만들 수 있다는 장점이 있다. 열처리 공정 이전에 전기도금 방식을 이용하여 아연층을 증착 하였다. 전기도금 조건은 0.1 M의 염화 아연과 1 M의 염화 칼륨으로 구성된 용액에 -1.1 V를 인가하였다. 합성된 아연층은 열처리 공정에 의해 산화아연의 nanowire 구조체로 변환되고, SEM (scanning electron microscope)를 통해 표면 형상을 관찰 하였고, XRD (X-ray diffraction)을 통해 미세구조를 확인하였다. -1 V부터 1 V 범위의 전압을 흘려주어 형성된 소자의 전기적 특성을 확인하였고, 1 V를 인가하였을 때, 습도 변화에 따른 센서 소자의 저항변화를 통해 습도 센서로서의 특성을 확인 하였다.

  • PDF

공극 내 상대습도, 모세관압력, 표면에너지 변화에 따른 콘크리트 자기수축 (Relation between Autogenous Shrinkage of Concrete and Relative Humidity, Capillary Pressure, Surface Energy in Pore)

  • 이창수;박종혁
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.131-138
    • /
    • 2008
  • 물-결합재비가 낮은 고성능콘크리트의 자기건조에 의한 습도감소와 수축과의 연관성을 파악하기 위하여 물-결합재비 0.3, 0.4의 배합에 대하여 습도와 변형률을 측정하였다. 그 결과 물-결합재비 0.3의 콘크리트 내부 습도 감소는 약 10%, 수축변형률은 약 $320\times10^{-6}$을 나타내었고, 물-결합재비 0.4의 콘크리트의 경우 4%의 습도 감소와 $120\times10^{-6}$ 수축변형률을 나타내었으며 배합에 상관없이 습도와 변형률은 모두 강한 선형성을 보였다. 콘크리트 내부 습도 변화와 수축변형률의 관계를 보다 구체화하기 위하여 콘크리트 내부 공극을 단일 네트워크로 가정하고 확장 메니스커스 생성가정 하에 공극수에서 발생하는 모세관 압력과 수화조직체에서 발생하는 표면에너지 변화를 습도의 함수로 모델링하여 수축의 구동력으로 작용시킨 결과 실험값과 비교적 일치하는 값을 나타내었다. 이를 근거로 물-결합재비가 낮은 고성능 콘크리트에서 자기건조에 의한 습도감소는 20 nm 이하의 소형공극에서 발생함을 파악할 수 있었으며 따라서 자기수축에 대한 제어 방안은 이러한 소형공극에서의 공극수 표면장력과 포화도에 초점을 맞추어야 함을 확인할 수 있었다.

법랑질 수분 처리에 따른 친수성 치면열구전색제의 미세누출과 열구 침투도 평가 (In Vitro Evaluation of Microleakage and Penetration of Hydrophilic Sealants Applied on Dry and Moist Enamel)

  • 구재원;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제44권3호
    • /
    • pp.272-279
    • /
    • 2017
  • 이 연구의 목적은 2종의 친수성 치면열구전색제를 건조한 법랑질과 습한 법랑질에 적용하였을 때의 미세누출과 열구 침투도를 평가하는 것으로, 기존의 소수성 전색제인 $Clinpro^{TM}$와 비교하였다. 건전하고 우식이 없는 제3대구치 60개를 법랑질 수분 처리 방법과 전색제 종류에 따라 12개씩 다섯 군으로 나누었다. 전색제 적용 후 치아들을 열순환 시킨 뒤 1% 메틸렌블루 용액에 담갔다. 그리고 치아들을 두 번씩 절단한 뒤 절단면들을 광학 현미경과 이미지 분석 프로그램을 이용해 관찰하였다. Embrace $Wetbond^{TM}$는 건조한 표면과 습한 표면 모두에서 $Clinpro^{TM}$보다 많은 미세누출을 나타냈다. Ultraseal $XT^{(R)}$ $hydro^{TM}$는 건조한 표면에서는 $Clinpro^{TM}$와 유사한 미세누출을 보였으나, 습한 표면에서는 많은 미세누출을 보였다. 열구 침투도는 모든 군에서 통계적으로 유의한 차이가 없었다. 결론적으로 친수성 전색제들을 습한 법랑질에 적용했을 때 변연 봉쇄성이 향상되지 않았으며, 건조한 표면에 적용한 $Clinpro^{TM}$보다 낮은 변연 봉쇄성이 관찰되었다.

PF열교환기의 습표면 성능시험 (Wet Surface Performance Test of PF Heat Exchanger)

  • 조진표;김내현;최국광
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.314-320
    • /
    • 2000
  • In this study, the wet surface heat transfer coefficients and friction factors of PF heat exchangers are presented. Two sample with different fin pitch(1.25mm, 1.5mm) were tested. Tests were conducted in a open loop wind tunnel. The wet surface heat transfer coefficient was reduced following the procedure given in ARI 410-81. Results showed that the heat transfer coefficients of the heat exchanger with 1.5mm fin pitch were approximately the same as those with 1.25mm fin pitch, except at low reynolds number(Re<100), where the heat transfer coefficients of 1.5mm fin pitch were slighly higher than those with 1.25mm fin pitch. The friction factors of the 1.25mm fin pitch, however was 120 % to 160 % higher than those of the 1.5mm fin pitch. The wet surface heat transfer coefficients were lower than those of the dry surface. The wet surface friction factors, however, were higher than those of the dry surface.

  • PDF

선박용 중방식 수용성 도료의 sagging 결함 원인에 관한 연구 (A study on sagging failures of water-borne corrosion-protective marine coatings)

  • 김진억;천제일;한명수;우종식
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.80-81
    • /
    • 2014
  • 환경보호 정책에 대응하고 보건 및 안전의 수준 향상을 위한 수용성 도료의 적용 시, 일부 도장 공정에서 도막 건조의 지연으로 sagging 현상이 발생하였다. 이러한 sagging 현상이 일어난 원인을 실험을 통해 분석한 결과, 도료가 갖는 고유의 yield stress와 더불어 습도 및 통기 상태 등의 시공 환경이 지배적인 영향을 미친다고 파악되었다. Sagging 현상의 재발을 방지하기 위해서는 높은 sagging 저항성을 갖는 도료의 선정뿐만 아니라 도장 공장의 적절한 온/습도 및 환기 제어가 선행되어야 한다.

  • PDF

공랭식 열펌프의 습표면 핀-관 증발기의 현장 성능 시험 (In-Situ Performance Test of a Wet Surface Finned-Tube Evaporator of an Air Source Heat Pump)

  • 백영진;장영수;김영일
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.818-826
    • /
    • 2001
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist, From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. since current procedure underpredicted the experimental sensible heat factor(SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test in necessary.

  • PDF

습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성 (Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions)

  • 장근선
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.

열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험 (An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design)

  • 권정태;임효재;박경우;김창업;김경민;권영철
    • 에너지공학
    • /
    • 제17권1호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 연구는 착상이 일어나는 조건에서 작은 사각 덕트내의 습공기의 층류유동에서 열 및 물질전달특성을 이해하고자 수행되었다. 알루미늄 평판이 열교환기의 핀부분을 모사하기 위하여 사용되었다. 알루미늄 표면온도는 착상조건에서의 열 및 물질전달 특성을 조사하여 해석하기 위하여 측정되었다. 또한 열교환기 공기측 채널에서 착상에 의한 air-blocking효과를 화인하기 위해 압력강하가 측정되었다. 그리고 착상조건에서 습공기의 국소 특성을 해석하기 위한 방법이 제시되었다.