• Title/Summary/Keyword: 폴리스티렌

Search Result 294, Processing Time 0.041 seconds

Growth of Candida albicans Biofilm is Inhibited by Salvia miltiorrhiza (단삼에 의한 Candida albicans 바이오필름 발달의 억제)

  • Lee, Heung-Shick;Kim, Younhee
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.3
    • /
    • pp.465-472
    • /
    • 2019
  • Candida albicans is an opportunistic human pathogen that causes infections. Candidiasis is often related to antifungal resistance because the pathogen has the ability to form biofilms. In a previous study, we found that the Salvia miltiorriza ethanol extract demonstrated anticandidal activity by altering membrane permeability and inhibiting the cell wall synthesis in C. albicans. Our results here demonstrate that $78{\mu}g/ml$ of the S. miltiorriza extract significantly diminished the early stage biofilms formed by 10 clinical C. albicans isolates by 51.3%; this was analyzed by 2,3-Bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide salt (XTT) reduction assay. The effect of the S. miltiorrhiza extract on the adhesion of C. albicans cells to polystyrene plates and germ tube formation was examined via microscopic investigation. Although the density of the adhered cells was remarkably reduced up on incubation with $39{\mu}g/ml$ S. miltiorrhiza extract, germ tube formation by C. albicans was rarely affected. Quantitative real-time PCR analysis showed that the S. miltiorrhiza extract downregulated the expression of C. albicans hypha-specific genes, EAP1 by 34.7% (p < 0.001), ALS1 by 45.0% (p < 0.001), ALS3 by 48.1% (p < 0.001), and ECE1 by 21.3% (p = 0.006), respectively. Our data suggest that the S. miltiorrhiza ethanol extract significantly inhibited the early stage of biofilm formation by C. albicans by interfering with cell adhesion, by downregulating EAP1, ALS1 and ALS3, and presumably by modifying the cell wall and membrane structure.

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.

Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography (전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가)

  • Lee, Jin-Wook;Kee, Seong-Hoon;Lee, Kang Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.11-20
    • /
    • 2022
  • The main purpose of this study is to investigate the applicability of the shear wave tomography technology as a non-destructive testing method to evaluate the debonding between the track concrete layer (TCL) and the hydraulically stabilized based course (HSB) of concrete slab tracks for the Korea high-speed railway system. A commercially available multi-channel shear wave measurement device (MIRA) is used to evaluate debonding defects in full-scaled mock-up test specimen that was designed and constructed according to the Rheda 200 system. A part of the mock-up specimen includes two artificial debonding defects with a length and a width of 400mm and thicknesses of 5mm and 10mm, respectively. The tomography images obtained by a MIRA on the surface of the concrete specimens are effective for visualizing the debonding defects in concrete. In this study, a simple image processing method is proposed to suppress the noisy signals reflected from the embedded items (reinforcing steel, precast sleeper, insert, etc.) in TCL, which significantly improves the readability of debonding defects in shear wave tomography images. Results show that debonding maps constructed in this study are effective for visualizing the spatial distribution and the depths of the debondiing defects in the railway concrete slab specimen.

Current Status and Management of Nanoplastics Exposed in Environment (환경 중 노출되는 나노플라스틱의 현황 및 관리실태)

  • Ha-neul Park;Jeonggue Park;Younghun Kim
    • Clean Technology
    • /
    • v.30 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • Nanoplastics (NP) exhibit distinct material properties compared to microplastics (MP), necessitating their separate recognition. Review of research outcomes and policy documents on NP reveals that most policy frameworks predominantly define MPs as solid synthetic polymer materials measuring 5 mm or less, but do not distinguish them from NP. However, recent revisions in regulations by the EU classify NPs as particles that range in size from 1 to 1,000 nm, as confirmed by some academic studies. Research on NPs often relies on experimental investigations centered around water systems, with a focus on high-concentration experimental conditions using spherical polystyrene-based NPs in behavior and impact studies. Notably, the environmental behavior characteristics of NP show differences in influence depending on the NP type, emphasizing the need for field simulation research. These challenges are mirrored in Korean society, so it is necessary to redefine NP to be distinct from MP in both research and policy. This study aimed to assess the current state of NP management globally and domestically and highlight policy considerations and issues in the existing response to NP. Upon comprehensive review, it becomes apparent that reaching an international agreement on MP faces methodological limitations, which could potentially burden efforts to precisely define NP size. Therefore, referencing the EU's recent regulatory revisions is crucial in domestic policy. Specific adjustments should commence from the MP concept through insights from the domestic industry, guidance from the academic community, and thorough discussions to ensure social acceptance.

Identification of Microplastics in Sea Salts by Raman Microscopy and FT-IR Microscopy (라만 및 FT-IR 현미경을 이용한 천일염 중 미세플라스틱 분석)

  • Cho, Soo-Ah;Cho, Won-Bo;Kim, Su-Bin;Chung, Jae-Hak;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.243-251
    • /
    • 2019
  • Microplastics (MP) are found in large quantities in the oceans, posing a major threat to the ecosystem. In Korea, MPs have been reported to be detected in sea salts. In order to analyze MPs, information on their composition, size, and shape is required. FT-IR microscopy is used frequently to measure sizes larger than 20 ㎛. Recently, however, Raman microscopy, which can analyze ultrafine plastics below 20 ㎛, has been applied extensively. In this study, 10.0 g samples of commercially available salts were dissolved and filtered through a 45 ㎛ mesh filter with a size of 25.4 mm × 25.4 mm. These filtered samples were then analyzed by both FT-IR microscopy and Raman microscopy. A total of four MPs, including three polyethylene (PE) of size 70-100 ㎛ and a polypropylene (PP) of size 170 ㎛, were detected by FT-IR microscopy, while 10 MPs, including nine PE of size 10-120 ㎛ and one polystyrene (PS) of size 40 ㎛, were detected by Raman microscopy. Approximately, 1,000 MPs/kg was estimated, which was almost two times higher than the previous reported levels (~550-681 particles/kg in sea salts); this is because Raman microscopy can detect much smaller MPs than FT-IR microscopy. A total of 113 particles were found using Raman microscopy: Carbon (35, 31.5 %), minerals (28, 25 %), and glass (16, 14.4 %) were dominant, forming around 70% of the total, but MPs (10, 8.8 %) and cellulose (5, 4.5 %) were also found. Raman microscopy has great potential as an accurate method for measuring MPs, as it can measure smaller size MPs than FT-IR microscopy. It also has a reduced sample preparation time.

The Optimal Condition of Performing MTT Assay for the Determination of Radiation Sensitivity (방사선 감수성 측정법으로서 MTT 법 시행 시의 최적 조건에 대한 연구)

  • Hong, Se-Mie;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 2001
  • Purpose : The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Materials and Methods : Four human cancer cell lines - PCI-1, SNU-1066, NCI-H630 and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy. For clonogenic assay, cells in $25\;cm^2$ flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for $10\~14$ days. For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. Results : There was minimal variation in the values gained from these two methods with the standard deviation generally less than $5\%$, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the $R^2$ value of $0.975\~0.992$ between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than $30\%$). For cells with low plating efficiency (less than $30\%$), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was after 6 doubling times for the results compatible with those of clonogenic assay, at least after 4 doubling times was required for valid results. In consideration of practical limits of assay (12 days, in this study) cells with doubling time more than 3 days were inappropriate for application. Conclusion : In conclusion, it is found that MTT assay can successfully replace clonogenic assay of tested cancer cell lines after irradiation only if MTT assay was undertaken with optimal assay conditions that included plating efficiency of each cell line and doubling time at least.

  • PDF

Regional cooperation of NOWPAP MERRAC against marine litter from sea-based activities in the Northwest Pacific region (북서태평양 지역의 해상기인 해양쓰레기 저감을 위한 NOWPAP 방제지역활동센터의 지역협력 활동현황 분석 및 향후 발전방향)

  • Noh, Hyon-Jeong;Oh, Jeong-Hwan;Kang, Seong-Gil;Kang, Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.3
    • /
    • pp.150-159
    • /
    • 2008
  • The marine litter generated as by-products of human activities and economic development enters to the sea through rivers or stream Indirectly, and through sea-based activities directly. It is commonly comprised of materials that degrade very slowly, such as various plastic products, polystyrene, glass, rubber, metal, wood, derelict fishing nets, wire, rope and so on. Such litter is found in the water column and on the seafloor as well as coastal areas In the Northwest Pacific region. It causes injury or death of human and other living organisms and also accident or damage of the vessel. It is not only a problem of country but also regional and/or global problem because it is transported by currents and winds from one country to another. In this regard, Northwest Pacific Action Plan (NOWPAP) Marine Litter Activity (MALITA) project had been carried out during 2006-2007 biennium and NOWPAP Regional Action Plan on Marine Litter (RAP MALI) has been also continuously implemented in the 2008-2009 biennium as next phase step of MALITA. MERRAC, one of four Regional Activity Centres (RACs) of NOWPAP, has developed monitoring guidelines, sectoral guidelines, and brochures related to sea-based marine litter and port reception facilities and services through MALITA project. Based upon these output, MERRAC will continuously implement relevant activities of RAP MALI in order to help to establish and improve a regional mechanism to deal with the sea-based marine litter problem. This paper aims to introduce MERRAC activities under MALITA and RAP MALI, and to suggest several recommendations to reduce marine litter in the NOWPAP region.

  • PDF

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Photon Beam (조직 불균질성에 의한 고에너지 광자선의 선량변화)

  • Kim, Young-Ai;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.277-283
    • /
    • 1995
  • Purpose : This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up to the loss of charged particle equilibrium in the tissues around the air-tissue interfaces. Materials and Methods : The 6 and 10-MV photon beam in dual energy linear accelerator were used to measure the surface dose at the air-tissue interface The polystyrene phantom sized $25{\times}25{\times}5\;cm^3$ and a water phantom sized $29{\times}29{\times}48\;cm^3$ which incorporates a parallel-plate ionization chamber in the distal side of air gap were used in this study. The treatment field sizes were $5{\times}5\;cm^2,\;10{\times}10\;cm^2\;and\;20{\times}20\;cm^2$. Air cavity thickness was variable from 10 mm to 50 mm. The observed-expected ratio (OER) was defined as the ratio of dose measured at the distal junction that is air-tissue interface to the dose measured at the same point in a homogeneous phantom. Results : In this experiment, the result of OER was close or slightly over than 1.0 for the large field size but much less (about 0.565) than 1.0 for the small field size in both photon energy. The factors to affect the dose distribution at the air-tissue interface were the field size, the thickness of air cavity. and the photon energy. Conclusion : Thus, the radiation oncologist should take into account dose reduction at the air-tissue interface when planning the head and neck cancer especially pharynx and laryngeal lesions, because the dose can be less nearly $29{\%}$ than predicted value.

  • PDF