• Title/Summary/Keyword: 폴라크레인

Search Result 2, Processing Time 0.015 seconds

Seismic Analysis of Nuclear Power Equipment Related to Design (원전기자재 설계와 관련된 내진해석)

  • Lee, Woo-Hyung;Cho, Jong-Rae;Roh, Min-Sik;Ryu, Jeong-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.317-323
    • /
    • 2011
  • We use the finite element method to analyze the seismic design of a liquid storage tank for a polar crane at a nuclear power plant. We obtained the natural frequency and vibration modes by modal analysis, and we evaluated the seismic stability by response spectrum analysis. Furthermore, the seismic analysis of the tank was accomplished by analyzing not only the forces applied to the wall by the sloshing of the liquid, but also the safe-shutdown earthquake condition for the tank. We propose a seismic-design process and a seismic-analysis method for liquid storage tanks based on the commercial finite element analysis program, ANSYS.

지반특성에 따른 면진 및 비면진구조물의 가속도응답 영향평가

  • Yoo, Bong;Lee, Jae-Han;Koo, Kyung-Hoe
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.392-397
    • /
    • 1996
  • 지반특성에 따라 지진발생시 면진구조물과 비면진 구조물의 응답특성이 어떠한가를 평가하기위해, 1940 El Centro 지진을 입력지진으로 하고, 면진구조물로는 가압경수형 원자로격납건물을 이용하여 수평(NS) 및 수직지진입력에 대한 시간이력해석을 수행하였다. 0.5Hz 수평면진 구조물의 경우 수평방향 가속도응답은 지반특성에 무관하게 거의 변화가 없으며, 또 2Hz 이상에서 비면진구조물의 수평지진가속도응답보다 현저히 낮은 가속도응답을 갖는다. 면진베어링의 수직방향 21Hz 고유진동수는 풍화암의 경우 수직방향 가속도응답에 영향을 주지 않으나. 경암의 경우 원자로지지점에서의 수직방향 가속도응답을 전반적으로 증가시킨다. 비면진 구조물의 경우 지반의 강성이 약할수록 가속도응답이 비교적 큰 폴라크레인위치에서 수평 및 수직방향 가속도응답이 감소되는 것으로 나타났으며, 특히 수직방향의 가속도응답이 크게 감소하는 것으로 나타났다.

  • PDF