• Title/Summary/Keyword: 폭-두께 비

Search Result 707, Processing Time 0.028 seconds

Effect of Quercus acutissima CARRUTHERS Extracts on the Lipid Metabolism (도토리추출물이 흰쥐의 체내 지질대사에 미치는 영향)

  • Sung, In-Suk;Kim, Myung-Joo;Cho, Soo-Yeul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.2
    • /
    • pp.327-333
    • /
    • 1997
  • This study was conducted to investigate the effect of Quercus acutissima CARRUTHERS extracts on lipid metabolism. Sprague-Dawley male rats$(110{\pm}10g)$ were fed on containing normal and high fat diets. They were orally administrated(0.02g/100g B.W.) of Quercus aculissima CARRUTHERS ethylacetate-extract and water-extract at the same time once a day respectively. The rats were sacrificed after 6 weeks of feeding periods. In high fat diet group, liver and heart weight were increased but kidney weight was decreased. Contents of total lipid, triglyceride and phospholipid were increased in high fat diet groups. But the degree of increment was reduced by administration of Quercus acutissima CARRUTHERS extracts and water extract was more effective. Significant decrease in serum total lipid content by administration Quercus acutissima CARRUTHERS extracts was not due to decrease of triglyceride content but total cholesterol content. Whereas HDL-cholesterol content was significantly decreased in high fat diet group and improved by administration of Quercus acutissima CARRUTHERS extracts. Total lipid, triglyceride and total cholesterol contents in liver were also increased in high fat diet group but phospholipid content was significantly decreased. The results indicate that Quercus acutissima CARRUTHERS extracts were effective in preventing hyperlipidemia and water extract was more effective.

  • PDF

Effects of Shipping Temperature and Precooling Treatment of Everbearing Strawberry Cultivars 'Goha' and 'Flamenco' Grown on Highland through Export Simulation (모의 수출 실험을 통한 고랭지 사계성 딸기 'Goha'와 'Flamenco'의 유통 온도 및 예냉 처리효과)

  • Eum, Hyang Lan;Bae, Sang Jun;Hwang, Dae Keun;Yeoung, Young Rog;Hong, Sae Jin
    • Horticultural Science & Technology
    • /
    • v.32 no.2
    • /
    • pp.202-209
    • /
    • 2014
  • This study was conducted to investigate the effects of low temperature shipping condition and precooling treatments (forced air and room cooling) on everbearing strawberry through export simulation of 'Goha' and 'Flamenco' cultivars. After harvest, it took two days to prepare export procedure such as precooling, sorting, storage, transportation, quarantine and handling, and then everbearing strawberry was carried out shipping at room ($20-25^{\circ}C$) or low ($8^{\circ}C$) temperature conditions. In the case of shipping at room temperature, weight losses of both cultivars were increased up to 10% after 2 days where 'Goha' being 2% higher than that of ' Flamenco'. In 'Flamenco' cultivar, shipping temperature and precooling treatment were not effective in firmness and soluble solids contents during transporting periods. However, in 'Goha' cultivar, room cooling treatment and low shipping temperature were effective in maintaining firmness until 4 days after shipping. Especially titratable acidity was affected by shipping temperature ($P{\leq}0.001$) and precooling treatments ($P{\leq}0.05$) in 'Goha' cultivar. Also shipping temperature under $8^{\circ}C$ delayed coloring and decay incidence of both strawberry cultivars, and precooling treatments of both forced air and room cooling reduced frequency of decay. The shelf life of everbearing strawberry at low shipping temperature was extended more than 4 days compared with shipping at room temperature. Precooling treatment including forced air or room cooling will be useful for the two cultivars when they are transported at low temperature. In 'Flamenco' cultivar, the effect of forced air and room cooling was similar, whereas in 'Goha' room cooling was more effective.

Changes in Mean Platelet Volume and Platelet Distribution Width after Therapy in Childhood Idiopathic Thrombocytopenic Purpura (소아 특발성 혈소판 감소성 자반증 환아에서 치료경과에 따른 평균 혈소판용적과 혈소판용적 분포폭의 변동)

  • Kim, Jong Tai;Lee, Kyung Won;Kim, Soon Nam;Kim, Moon Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.505-511
    • /
    • 2002
  • Purpose : Mean platelet volume(MPV) and platelet distribution width(PDW) are useful parameters in evaluating disorders of platelets. In cases with idiopathic thrombocytopenic purpura(ITP), they change as platelet count increases. In this study, we compared the values of MPV and PDW in ITP patients at diagnosis with those of normal children. We also studied whether the early changes in MPV may predict the clinical course. Methods : From December 1995 to May 2001, 71 patients with ITP were admitted to Ajou University Hospital. They were treated with IVIg 400 mg/kg for five days and MPV, PDW, platelet count were analysed. Normal control group(n=38) was compared. The study group was divided into acute and chronic forms, and also divided into group A, good early responders whose platelets increased more than $100,000/{\mu}L$ within 5 days and group B who did not. Results : Mean value of MPV at diagnosis in ITP patients was lower than the normal control group(P<0.05). In group A, MPV was abruptly increased on the first day after IVIg and then started to decrease. But in group B, MPV was steadily increased until the fourth day after IVIg. In the normal control group, there were inverse correlations between platelet count and MPV(r=-0.415, P<0.05), but in ITP patients, there were positive relationships between platelet count and MPV(r=0.646, P<0.05) at diagnosis. Conclusions : MPV at diagnosis of ITP was lower than the normal control. MPV and PDW could not predict the course of ITP patients, but MPV could distinguish good early responders. More research is needed to find out the reasons of decreased MPV at diagnosis of ITP.

Improvement of Radar Rainfall Estimation Using Radar Reflectivity Data from the Hybrid Lowest Elevation Angles (혼합 최저고도각 반사도 자료를 이용한 레이더 강우추정 정확도 향상)

  • Lyu, Geunsu;Jung, Sung-Hwa;Nam, Kyung-Yeub;Kwon, Soohyun;Lee, Cheong-Ryong;Lee, Gyuwon
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.109-124
    • /
    • 2015
  • A novel approach, hybrid surface rainfall (KNU-HSR) technique developed by Kyungpook Natinal University, was utilized for improving the radar rainfall estimation. The KNU-HSR technique estimates radar rainfall at a 2D hybrid surface consistings of the lowest radar bins that is immune to ground clutter contaminations and significant beam blockage. Two HSR techniques, static and dynamic HSRs, were compared and evaluated in this study. Static HSR technique utilizes beam blockage map and ground clutter map to yield the hybrid surface whereas dynamic HSR technique additionally applies quality index map that are derived from the fuzzy logic algorithm for a quality control in real time. The performances of two HSRs were evaluated by correlation coefficient (CORR), total ratio (RATIO), mean bias (BIAS), normalized standard deviation (NSD), and mean relative error (MRE) for ten rain cases. Dynamic HSR (CORR=0.88, BIAS= $-0.24mm\;hr^{-1}$, NSD=0.41, MRE=37.6%) shows better performances than static HSR without correction of reflectivity calibration bias (CORR=0.87, BIAS= $-2.94mm\;hr^{-1}$, NSD=0.76, MRE=58.4%) for all skill scores. Dynamic HSR technique overestimates surface rainfall at near range whereas it underestimates rainfall at far ranges due to the effects of beam broadening and increasing the radar beam height. In terms of NSD and MRE, dynamic HSR shows the best results regardless of the distance from radar. Static HSR significantly overestimates a surface rainfall at weaker rainfall intensity. However, RATIO of dynamic HSR remains almost 1.0 for all ranges of rainfall intensity. After correcting system bias of reflectivity, NSD and MRE of dynamic HSR are improved by about 20 and 15%, respectively.

Evaluation on Spectral Analysis in ALOS-2 PALSAR-2 Stripmap-ScanSAR Interferometry (ALOS-2 Stripmap-ScanSAR 위상간섭기법에서의 스펙트럼 분석 평가)

  • Park, Seo-Woo;Jung, Seong-Woo;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.351-363
    • /
    • 2020
  • It is well known that alluvial sediment located in coastal region has been easily affected by geohazard like ground subsidence, marine or meteorological disasters which threaten invaluable lives and properties. The subsidence is a sinking of the ground due to underground material movement that mostly related to soil compaction by water extraction. Thus, continuous monitoring is essential to protect possible damage from the ground subsidence in the coastal region. Radar interferometric application has been widely used to estimate surface displacement from phase information of synthetic aperture radar (SAR). Thanks to advanced SAR technique like the Small BAseline Subset (SBAS), a time-series of surface displacement could be successfully calculated with a large amount of SAR observations (>20). Because the ALOS-2 PALSAR-2 L-band observations maintain higher coherence compared with other shorter wavelength like X- or C-band, it has been regarded as one of the best resources for Earth science. However, the number of ALOS-2 PALSAR-2 observations might be not enough for the SBAS application due to its global monitoring observation scenario. Unfortunately, the number of the ALOS-2 PALSAR-2 Stripmap images in area of our interest, Busan which located in the Southeastern Korea, is only 11 which is insufficient to apply the SBAS time-series analysis. Although it is common that the radar interferometry utilizes multiple SAR images collected from same acquisition mode, it has been reported that the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometric application could be possible under specific acquisition mode. In case that we can apply the Stripmap-ScanSAR interferometry with the other 18 ScanSAR observations over Busan, an enhanced time-series surface displacement with better temporal resolution could be estimated. In this study, we evaluated feasibility of the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometric application using Gamma software considering differences of chirp bandwidth and pulse repetition frequency (PRF) between two acquisition modes. In addition, we analyzed the interferograms with respect to spectral shift of radar carrier frequency and common band filtering. Even though it shows similar level of coherence regardless of spectral shift in the radar carrier frequency, we found periodic spectral noises in azimuth direction and significant degradation of coherence in azimuth direction after common band filtering. Therefore, the characteristics of spectral bandwidth in the range and azimuth direction should be considered cautiously for the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometry.

A Longitudinal Study for 3 Years on Myopic Refractive Error Changes of Myopic Children Among Patients of a Korean Optometry Clinic (국내 한 안경원을 방문한 근시 어린이의 3년간 근시도 변화의 추적 연구)

  • Kim, Jin-Suk;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.249-254
    • /
    • 2012
  • Purpose: To investigate amount of myopic progression with increase of age for children myopes among patients of a Korean optometry clinic. Methods: It has followed up 99 children subjects (male 55, female 44) who had no ocular disease and have visited a Korean optometric clinic for mean $33{\pm}8$ months (13 to 54 months) since June of 2001. Mean age of subjects at first visit was $118{\pm}23$months. Non-cycloplegic refractive error were measured 6 times using Canon RK-3(Japan) every mean 6 months. Results: For all subjects mean of refractive errors increased -0.78 D per year from $-2.02{\pm}1.05D$ at first visit to $-4.18{\pm}1.30D$ at final visit with longitudinal study, but -0.19 D per year with cross-section study, which showed a big difference between two methods. Mean of astigmatic refractive error increased -0.15 D per year. As progression of refractive error according to ages at first visit, refractive errors increased -1.04 D per year for 6 years old, -0.9 D for 7 years old, -0.89 D for 8 years old, -0.89 D for 9 years old, -0.74 D for 10 years old, -0.74 D for 11 years old and -0.72 D for 12 years old. And it showed a tendency that the younger age was the higher progression of myopia. However it was not significantly different between each groups. Conclusions: Follow-up results for myopic children among patients of a Korean optometry clinic showed increase of -0.78 D for myopic refractive error and -0.14 D for astigmatic refractive error per year.

A Study on the Hull-dimension of 89 ton class Stow-net Vessel with Stern-fishing (89톤급 선미식 안강망어선의 선형치수에 관한 연구)

  • Park, Je-Ung;Lee, Hyeon-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.159-165
    • /
    • 1997
  • This paper presents the optimum dimension of 89 ton class stow-net vessel with stern-fishing. The model of basic design is developed by using the optimization techniques referring to objective function and numerous constraints as follows; speed, fishing quantity, fishing days, catch per unit effort(CPUE), and weight/ratio of main dimensions, etc. Thus, the basic design of stow-net fishing vessel is built up by using the optimization of the design variables called the economic optimization criteria, and the objective function represents the criterion which is cost benefit ratio(CBR). The main conclusions are as follows. 1. S/W for decision of optimum hull size is developed in 89 ton class stow-net fishing vessel which is constructed with optimization of the design variables called the economic optimization criteria. 2. For optimum ship dimensions in 89 ton class stow-net fishing vessel, the hull dimensions can be obtained in the range of L= 27.3m, B = 6.6m, D = 2.80m, Cb = 0.695, T/D = 0.80, $\Delta$(displacement)=281.7ton with 10 knots.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Breeding and characterization of 'Creamy', a new interspecific hybrid between Pleurotus ferulae and P. tuoliensis (아위느타리와 백령느타리의 종간교잡 품종 '크리미'의 육성 및 특성)

  • Oh, Min-Ji;Shin, Pyung-Gyun;Lim, Ji-Hoon;Oh, Youn-Lee;Jang, Kab-Yeul;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.224-229
    • /
    • 2019
  • The two most common mushroom species grown in Korea are pearl oyster mushroom (Pleurotus ostreatus) and king oyster mushroom (P. eryngii). In recent years, the production of king oyster mushroom greatly increased due to the automation of the cultivation facilities, and it became a major export mushroom owing to its excellent shelf life. However, the increase in the production of king oyster mushroom led to a decline in its market price; thus, necessitating the development of new mushroom species that could replace king oyster mushroom, to diversify the mushroom market for the benefit of both, the producers and the consumers. The Mushroom division at the National Institute of Horticultural & Herbal Science (NIHHS) reported the development of a new interspecific hybrid between P. ferulae and P. tuoliensis, referred to as 'Creamy.' Two parental strains KMCC00430 (Bisan2ho, P. ferulae) and KMCC00461 (P. tuoliensis) were selected based on the results of genetic resource analysis, and their monokaryons were collected. About 1,000 Mon-Mon crosses were performed and 73 of them were selected. Following repeated cultivation tests and strain analyses, we selected strain 7773, which had a bright creamy pileus and a thick straight stipe, and named it 'Creamy.' Optimum temperature for mycelial growth of Creamy was 25-30℃, and that for fruiting body growth was 16℃. The pileus, which had a brighter creamy color, was small in size with a diameter of 61.2 mm. Although it was cultivated in suboptimal conditions, such as low temperature and high CO2 concentration, Creamy was characterized by its straight and smooth stipe. Field production tests and further analyses indicated that the yield of Creamy was 5% higher than that of Baekhwang. It is expected that Creamy, the new interspecific hybrid with a bright creamy pileus and a pleasant flavor, will help create new opportunities for mushroom farmers and diversify the mushroom market.

Comparative Analysis of Heavy Metal Contamination, Mineral Composition and Spectral Characteristics of White, Reddish Brown and Mixed Precipitates Occurring at Osip Stream Drainage, Gangwondo, South Korea (강원도 오십천 수계에 분포하는 백색침전물, 적갈색침전물 및 혼합침전물의 중금속 오염, 광물조성 및 분광학적 특성의 비교분석)

  • Lim, Jeong Hwa;Yu, Jaehyung;Shin, Ji Hye;Koh, Sang-Mo
    • Economic and Environmental Geology
    • /
    • v.52 no.1
    • /
    • pp.13-28
    • /
    • 2019
  • This study analyzed precipitation environment, heavy metal contamination, and mineral composition of white, reddish brown and mixed precipitates occurring at the Osip stream drainage, Gangwondo. Furthermore, spectral characteristics of the precipitates associated with heavy metal contamination and mineral composition was investigated based on spectroscopic analysis. The pH range of the precipitates was 4.43-6.91 for white precipitates, 7.74-7.94 for reddish brown precipitates, and 7.59-7.9 for the mixed precipitates, respectively. XRF analysis revealed that these precipitates were contaminated with Ni, Cu, Zn, and As. The white precipitates showed high Al concentration compared to reddish brown precipitates as much as 3.3 times, and the reddish brown precipitates showed high Fe concentration compared to white precipitates as much as 15 times. XRD analysis identified that the mineral composition of the white participates was aluminocoquimbite, gibbsite, quartz, saponite, and illite, and that of reddish brown precipitates was aluminum isopropoxide, kaolinite, goethite, dolomite, pyrophyllite, magnetite, quartz, calcite, pyrope. The mineral composition of the mixed precipitates was quartz, albite, and calcite. The spectral characteristics of the precipitates was manifested by gibbsite, saponite, illite for white precipitates, goethite, kaolinite, pyrophyllite for reddish brown precipitates, and albite for the mixed precipitates, respectively. The spectral reflectance of the precipitates decreased with increase in heavy metal contamination, and absorption depth of the precipitates indicated that the heavy metal ions were adsorbed to saponite and illite for white precipitates, and goethite and magnetite for reddish brown precipitates.