• Title/Summary/Keyword: 포텐쇼미터

Search Result 2, Processing Time 0.016 seconds

Reliability Evaluation of ACP Component under a Radiation Environment (방사선환경에서 ACP 주요부품의 신뢰도 평가)

  • Lee, Hyo-Jik;Yoon, Kwang-Ho;Lim, Kwang-Mook;Park, Byung-Suk;Yoon, Ji-Sup
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.309-322
    • /
    • 2007
  • This study deals with the irradiation effects on some selected components which are being used in an Advanced Spent Fuel Conditioning Process (ACP). Irradiation test components have a higher priority from the aspect of their reliability because their degradation or failure is able to critically affect the performance of an ACP equipment. Components that we chose for the irradiation tests were the AC servo motor, potentiometer, thermocouples, accelerometer and CCD camera. ACP facility has a number of AC servo motors to move the joints of a manipulator and to operate process equipment. Potentiometers are used for a measurement of several joint angles in a manipulator. Thermocouples are used for a temperature measurement in an electrolytic reduction reactor, a vol-oxidation reactor and a molten salt transfer line. An accelerometer is installed in a slitting machine to forecast an incipient failure during a slitting process. A small CCD camera is used for an in-situ vision monitoring between ACP campaigns. We made use of a gamma-irradiation facility with cobalt-60 source for an irradiation test on the above components because gamma rays from among various radioactive rays are the most significant for electric, electronic and robotic components. Irradiation tests were carried out for enough long time for total doses to be over expected threshold values. Other components except the CCD camera showed a very high radiation hardening characteristic. Characteristic changes at different total doses were investigated and threshold values to warrant at least their performance without a deterioration were evaluated as a result of the irradiation tests.

  • PDF

Knee Rehabilitation System through EMG Signal analysis and BLDC Motor Control (근전도 신호 분석 및 BLDC모터 제어를 통한 무릎재활시스템)

  • Kwon, Hyeong-Gi;Ko, Hyeong-Gyu;Song, Yoon-Oh;Son, Eui-Seong;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.1009-1018
    • /
    • 2019
  • This paper describes the design and implementation of a rehabilitation medical device based on a EMG measurement. Rehabilitation systems are controlled using BLDC motors and motor drives. The BLDC motor drive controls the operation and the speed controls the drive through the external servo motor. In addition, potentiometer coupled to the outside of the motor transmits information about the position of the load being rotated by the motor. The rehabilitation algorithm is controlled by limiting the maximum angle of 0 to 120 by utilizing the motor according to the user setting stage during the rehabilitation exercise. The walking algorithm compensates motor control for the low leg of the signal using the difference value of the signal obtained with the surface denser attached to both inner muscles. The motor and surface denser are utilized for the walk motion to control the maximum angle of 0 to 80.