• 제목/요약/키워드: 포집기

검색결과 271건 처리시간 0.037초

Carbon Nitrides 나노구조체를 이용한 CO2 포집 연구의 최신동향 (A Review on Nanostructured Carbon Nitrides for CO2 Capture)

  • 하성진;이동기;김문희;박대환
    • 세라미스트
    • /
    • 제22권3호
    • /
    • pp.316-327
    • /
    • 2019
  • Carbon nitride has drawn broad interdisciplinary attention in diverse fields such as catalyst, energy storage, gas adsorption, biomedical sensing and even imaging. Intensive studies on carbon dioxide (CO2) capture using carbon nitride materials with various nanostructures have been reported since it is needed to actively remove CO2 from the atmosphere against climate change. This is mainly due to its tunable structural features, excellent physicochemical properties, and basic surface functionalities based on the presence of a large number of -NH or -NH2 groups so that the nanostructured carbon nitrides are considered as suitable materials for CO2 capture for future utilization as well. In this review, we summarize and highlight the recent progress in synthesis strategies of carbon nitride nanomaterials. Their superior CO2 adsorption capabilities are also discussed with the structural and textural features. An outlook on possible further advances in carbon nitride is also included.

GC/MS에 의한 저장중 츄잉껌 향기성분 변화연구 (Changes of Flavor Components in Chewing Gum during Storage by Gas Chromatography/Mass Spectrometry)

  • 신성기;김상호;이윤형;이규순
    • 한국식품과학회지
    • /
    • 제24권1호
    • /
    • pp.25-28
    • /
    • 1992
  • 츄잉껌 품질향상의 일환으로 저장기간 및 여러 가지 상대습도하에서 츄잉껌 향기성분의 변화를 GC/MS로 분석하였다. 츄잉껌 향기성분을 시료전처리로 포집하고 tetradecane을 내부표준용액으로 이용해서 각 성분과의 peak area ratio로써 향기성분함량의 감소량을 측정한 결과 저장초기에는 53% R.H 저장분 보다 33, 75% R.H에서 감소속도가 빨라으나 그 이후는 차이가 별로 없었으며 16주 후에는 $45{\sim}49%$의 잔존량을 나타내었다.

  • PDF

코안다효과를 이용한 필터에 관한 연구 (A Study on Improving Filter Performance Using Coanda Effect)

  • 김용선;석재준;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.99-104
    • /
    • 2020
  • Modern people spend a lot of time indoors. Oil mist has a very fatal effect on the cook's health. Range Hood's filter plays a very important role in removing oil mist from kitchen. In this study, we applied coanda effect to increase the collection efficiency of filter. Original, Bottom, Slide Three shapes were simulated, and the two shapes were measured and compared using a wind tunnel tester. Pressure loss is measured below 2.0mmAq for all three filters, making them easy to use indoors. The simulation results were 15% for the original filter, 22% for the bottom filter, and 30% for the slide filter. The wind tunnel tester obtained 26% of the original filter and 30% of the slide filter. Research is needed to increase the collection efficiency by 50%.

하나로 냉중성자원 진공계통의 운전 특성

  • 손우정;이문;김민수;최호영;한재삼;조성환;허순옥;안국훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.366-366
    • /
    • 2011
  • 냉중성자원은 하나로 반사체탱크에 위치한 수직공에 설치되어 노심에서 발생하는 열중성자를 감속재인 액체수소층을 통과시켜 냉중성자를 생산하는 설비로 수소가를 충전하고 있는 수소계통이 있으며, 21K의 극저온 액체수소/기체수소 2상(ttwo-phase)을 유지하기 위해 외부에서 유입되는 열침입을 최소화하기 위해 진공계통이 설치되어 있다. 진공계통은 수조내기기 집합체(In-Pool Assembly : IPA)의 액체수소 열사이펀, 감속재 용기 등의 냉중성자원 극저온 부풀들의 단열을 위하여 진공용기 내부진공도를 공정진공도 이하로 유지하기 위한 계통으로 고진공펌프, 진공배기탱크 및 저진공펌프의 조합으로 두 개의 진공펌프시스템과 진공박스, 배기수집탱크 및 밸브박스를 포함한 연결배관으로 설계되었다. 저진공펌프를 이용하여 대기압에서 고진공펌프 작동압력까지 도달한 후 고진공펌프를 가동하여 공정진공도 이하의 진공도를 확보하고, 고진공펌프로부터 배기되는 배출가스는 고진공펌프 후단에 설치된 진공배기탱크에 포집되며, 필요 시 저진공펌프레 의하여 배기수집탱크로 배출된다. 진공펌프시스템은 진공용기 내부의 압력이 공정진동고 이하로 유지되도록 연속적으로 가동되어 진공단열이 가능하다. 본 논문은 감속재인 수소를 액화상태로 유지하며, 공정진공도 이하로 충분히 유지되어 운전되는 진공계통의 특성을 원자로 운전 주기별로 소개하고자 한다.

  • PDF

저농도 이산화탄소 포집용 활성탄소섬유 흡착제의 질소작용기 함침연구 (Impregnation of Nitrogen Functionalities on Activated Carbon Fiber Adsorbents for Low-level CO2 Capture)

  • 황수현;김동우;정동원;조영민
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.176-183
    • /
    • 2016
  • Activated carbon fibers (ACFs) for $CO_2$ adsorption were prepared from polyacrylonitrile (PAN) fiber through the systematic processes such as oxidation, activation and amination with the focus on the formation of nitration functional groups. Textural analysis of test samples revealed the decrease of specific surface area and pore volume by chemical activation including amination. The ratio of micropores to the total volume was 0.85 to 0.91, which was high enough with the pore size of 1.57 to 1.77 nm. Nitrogen compounds such as imine, pyridine and pyrrole presenting favorable interforces to $CO_2$ molecules were formed throughout the whole preparation steps. The aminated ACF adsorbent showed the enhanced adsorption capacity, 0.40 mmol/g for low-level $CO_2$ flow (3000 ppm) at room temperature. Selectivity of $CO_2$ against dry air ($O_2$ & $N_2$) also increased from 1.00 to 4.66 by amination.

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

서브필터 형상에 따른 Oil-mist Filter의 포집효율 향상에 관한 연구 (A Study on the Collecting Efficiency of Oil-mist Filter according to the Sub-filter Shape)

  • 김용선;윤성민;신희재;고상철
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.16-23
    • /
    • 2019
  • Cooking oil in kitchen-fog is the most harmful factor to the health of a cook. The proposed filter is a tool that protects the cooked state, to prevent users from inhaling oil mist in the kitchen. Due to efficiency issues, existing filters are of the mesh type or baffle type. In this paper, CFD analysis is carried out to select a filter with low pressure loss and low efficiency, and to attach the sub-filter to improve efficiency. The results of the analysis on the collection efficiency and pressure loss of three sub-filters, i.e., circle type, droplet type, and cone type, showed that the collection efficiency was 64.09% and the pressure loss was 1.26 mmAq when the circle type sub-filter was applied. The position of the sub-filter showed the best efficiency and pressure loss when it was located at the bottom of the center of the gap of the main filter.

벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가 (Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process)

  • 김재영;임호;우제민;조성호;문종호;이승용;이효진;이창근;이종섭;민병무;박영철
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.419-425
    • /
    • 2017
  • 본 연구에서는 벤치급 건식 $CO_2$ 포집 성능평가 장치에서 흡수반응기 내부의 구조와 형태에 따른 K-계열 흡수제(KEP-CO2P2, 한국전력공사 전력연구원)의 성능특성을 확인하였다. 흡수반응기 혼합영역(mixing-zone)에 구조와 형태가 다르게 제작된 두 종류의 열교환기가 적용되었으며, 각각 CASE 1과 CASE 2로 나뉘어 동일한 조업조건으로 연속운전을 수행하였다. 연속운전동안 흡수반응 온도는 $75{\sim}80^{\circ}C$, 재생반응 온도는 $190{\sim}200^{\circ}C$, 그리고 반응기체($CO_2$) 농도는 12~14 vol%으로 설정하였다. 특히 흡수제의 흡수능 비교를 위해 흡수반응기 혼합영역의 차압을 400~500 mm$H_2O$로 유지하며 운전하였다. 또한 반응 후 채집한 시료는 반응성 비교를 위해 TGA를 이용하여 물성분석을 하였다. CASE 1 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 64.3%, 2.40 wt%으로 산출 되었고, CASE 2 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 81.0%, 4.66 wt%으로 산출되었다. 또한 반응 후 흡수제에 대한 TGA 측정 결과의 무게감량을 이용하여 흡수제의 동적흡수능을 계산한 결과, CASE 1과 CASE 2 실험에서 반응 후 흡수제의 동적흡수능은 각각 2.51 wt%와 4.89 wt%으로 산출되었다. 결론적으로 동일한 조업조건에서 흡수반응기 내부에 삽입되는 열교환기의 구조와 형태에 따라 흡수제의 성능 차이가 있는 것을 확인하였다.

시간 경과에 따른 저류층 압력 상승이 파이프라인, 탑사이드 및 주입정 내 CO2 거동에 미치는 영향에 대한 수치해석적 연구 (Numerical Analysis of CO2 Behavior in the Subsea Pipeline, Topside and Wellbore With Reservoir Pressure Increase over the Injection Period)

  • 민일홍;허철;최윤선;김현욱;조맹익;강성길
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권4호
    • /
    • pp.286-296
    • /
    • 2016
  • 해양 CCS는 화력발전소에서 배출되는 $CO_2$를 포집하여 해양 지중의 대수층이나, 고갈 유가스전까지 수송하여 저장하는 기술이다. 시간 경과에 따라 지중 저장소로 주입 및 저장되는 $CO_2$의 누적 양이 증가하며, 이는 저류층 압력의 상승을 동반한다. 저류층 압력의 상승은 수송 및 주입 시스템의 운전조건 변화를 유발한다. 따라서 초기 설계단계에서 이러한 사업시간의 경과에 따른 운전조건 변화를 반영한 분석이 요구된다. 본 연구에서는 국내 동해 대륙붕에 위치한 가스전을 $CO_2$ 저장소로 활용할 경우 시간 경과에 따른 해양 수송 및 주입 시스템 내 $CO_2$ 거동을 수치해석적 방법을 이용하여 분석하였다. 전체 시스템을 해저 파이프라인, 라이저, 탑사이드, 주입정으로 구성하고, 이를 OLGA 2014.1을 이용하여 모델링 및 해석하였다. 약 10년의 주입 운전기간동안 해저 파이프라인, 라이저, 탑사이드, 주입정에서의 $CO_2$ 압력과 온도, 상거동의 변화를 분석하였다. 이를 통해 해저 파이프라인 입구 압축기, 탑사이드 열교환기 및 주입정 정두 제어 등의 설계 방안을 제시하였다.

확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구 (A Study on Organic Solvent Measurement Using Diffusive Sampler)

  • 박미진;윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF