• Title/Summary/Keyword: 포스트텐셔닝

Search Result 13, Processing Time 0.023 seconds

Structural Effect of HDPE Greased Strand Applying to Post-tensioning in Reactor Containment Building (피복텐던을 적용한 원자로건물 포스트텐셔닝 구조효율성 분석)

  • Park, Jong-Hyok;Bang, Chang-Joon;Kim, Jwa-Young;Lim, Sang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.167-168
    • /
    • 2012
  • Analysis on structural effects which are reduction of friction coefficient and increase of tendon area by HDPE greased and large size strand in post-tensioning system of reactor containment building was carried out. Effective ratio of tendon force increases 67% to 83% by HDPE greased strand and vertical, horizontal internal section forces increased maximum 51%, 41% respectively. Tendon quantity could be reduced 30% by large size and HDPE greased strand that can maintain safety of ultimate internal pressure same as at present.

  • PDF

Constructability Effect of HDPE Greased Strand Applying to Post-tensioning in Reactor Containment Building (피복텐던을 적용한 원자로건물 포스트텐셔닝 시공효율성 분석)

  • Bang, Chang-Joon;Park, Jong-Hyok;Lee, Byong-Soo;Kim, Seok-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.169-170
    • /
    • 2012
  • It is analyzed that constructability of post-tensioning system applying HDPE greased strand that is greased and coated by high density polyethylene on a bare strand in reactor containment building. The improvement of corrosion resistance by greasing and HDPE coating on a strand makes transportation, handling and installation of tendon to be easier. Therefore, serial and repetitive process of post-tensioning composed of construction preparation, tendon installation, stressing and anchoring, grease injection could be improved parallel and lumping process of installation and grouting, stressing and anchoring.

  • PDF

Strengthening Depth Effect in Externally Post-tensioning Shear Strengthening of Pre-cracked Reinforced Concrete Beam (사전균열이 발생한 철근콘크리트 보의 외적 포스트텐셔닝 전단보강에서 보강깊이의 효과)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.19-26
    • /
    • 2018
  • This paper presents the shear strengthening effect of externally post-tensioning (EPT) method using high-strength steel rod in pre-cracked reinforced concrete (RC) beams. Three- and four-point bending tests were performed on a total of 8 specimens by adjusting the strengthening depths in the deviator position of EPT. The effective strengthening depths were 435, 535, and 610 mm. The pre-loading up to about 2/3 of ultimate load capacity measured in unstrengthened RC beam were applied in the beam to be post-tensioned. The EPT method was then applied to the pre-damaged RC beams and re-loading was added until the end of the test. EPT restored deflections of 3 mm or more, which account for about 40% of deflection when the pre-loading was applied. The shear strengthening increases more than 3 times and 36~107% in terms of the stiffness and load-carrying capacity compared to unstrengthening RC beams. The increased load-carrying capacities of the post-tensioned beam with strengthening depths of 435 and 535 mm are almost the same as 36~61%, and those of 610 mm are 84~107%, which shows the greatest shear strengthening effect.

Shear Strengthening by Externally Post-tensioning Steel Rods in Damaged Reinforced Concrete (RC) Beams (손상입은 철근콘크리트 보의 포스트텐셔닝 강봉을 이용한 전단 보강)

  • Lee, Swoo-Heon;Lee, Hee-Du;Park, Seong-Geun;Shin, Kyung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.3-10
    • /
    • 2018
  • This experimental investigation was conducted to observe the shear strengthening behavior of pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. A total of six simply supported beams - two control beams and four post-tensioned beams using external steel rods - were tested to failure in shear. The external steel rods of 18 mm or 28 mm diameter were respectively employed as post-tensioning material. The four post-tensioned beams have a V-shaped profile with a deviator (or saddle pin) located at mid-span, and the post-tensioning system increased the low load-carrying capacity and overcame a little bit of deflection caused by damage. Concretely, the load-carrying capacity and flexural stiffness were respectively increased by about 25~57% and 263~387% due to the post-tensioning when compared with the unstrengthened control beams.

Nonlinear Analysis using ABAQUS Software of Reinforced Concrete (RC) Beams Strengthened with Externally Post-tensioning Steel Rods (외적 포스트텐셔닝 강봉으로 보강된 철근콘크리트 보의 ABAQUS를 이용한 비선형해석)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Kim, Jin-Wook;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.11-17
    • /
    • 2018
  • Concrete is the well-used material in many architectural and civil structures. The behavior of concrete does exhibit a different characteristic in compression and tension, and it also shows an inelastic-nonlinear behavior. In addition, the concrete properties vary slightly depending on the environmental factor and manufacturer. These properties of concrete make the modeling or simulation of concrete material difficult. In reinforced concrete, particularly, there is a difficulty in bond-slip relationship between concrete and steel. However, in this paper, reserving remainder of these limits the finite element analysis for reinforced concrete beams through ABAQUS simulation has been carried out with some assumptions. Assumptions include the perfect bond of steel and concrete as well as the concrete damaged plasticity (CDP) in concrete property. There is a reasonable agreement between the experimental and numerical results, although the analytical strength and external rod deformation are slightly overestimated. The average and standard deviation between two results are 1.05 and 0.05, respectively. And the models and the computations lead to the evolution of fracture in bending beam.

Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement (외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

An Cracking and Ultimate Behavior of Post-tensioned Prestressed High Strength Concrete Beams (포스트텐셔닝 공법의 프리트스레스트 고강도 빔부재의 균열 및 극한 거동)

  • Lee, Seong-Cheol;Choi, Young-Cheol;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.323-326
    • /
    • 2005
  • Although many structures. with high strength concrete have been recently constructed, the flexural behavior of reinforced and prestressed concrete beams with high strength concrete is not exactly defined. This paper presents an experimental study on the flexural strength of the high strength concrete beams. Five large scale beams simply supported were tested and measured. Each beam was loaded by two symmetrical concentrated loads applied at 1.25m from the center of span. The concrete strength, the prestressed force and longitudinal tensile reinforcement ratio vary from beam to beam. From the experimental tests, the flexural strength from tests is larger than the nominal flexural strength of codes. Moreover, the initial crack-load is affected by the prestressed force and the crack width and spacing are controlled by the longitudinal tensile reinforcement ratio.

  • PDF