• Title/Summary/Keyword: 포름산이온 농도

Search Result 8, Processing Time 0.029 seconds

Damage Characteristics of Korean Traditional Textiles by Formaldehyde (포름알데히드에 의한 전통직물의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.353-364
    • /
    • 2014
  • Formaldehyde(HCHO) may have a damage effect on Korean traditional textiles, because concentration is high and occurrence frequency is frequent at the exhibition room and storage area. Total 20 specimens were prepared using 4 different materials (silk, cotton, ramie, hemp) after dyeing with 5 colors (undyed, red, yellow, blue, black). The specimens were exposed to HCHO gas in the test chamber. The gas acceleration test was conducted to identify the deterioration of Korean traditional textiles according to HCHO concentration(0.5, 1, 10, 100, 500ppm), to temperature-humidity condition at HCHO 500ppm, and deterioration conditions at HCHO 500ppm. Optical, chemical, and physical evaluation was carried out after the exposure. The results, color difference, grey scale rating, formate($HCO_2{^-}$) of some textiles increased at 500ppm, while pH decreased at 500ppm. Also, color difference, grey scale rating, formate($HCO_2{^-}$) of some textiles increased double damage at high temperatures & humidity, high humidity condition. But, damages of accelerated degradation textiles were slight, because of degradation degree and degradation products. The results suggest that determined the damage to the korean traditional textile, damage level, damage-weighted condition, damage to accelerated degradation textiles. In addition, formaldehyde damaged to yellowing of red textiles, bleaching of accelerated degradation textiles, formic acid damaged to bleaching of total 20 specimens.

Damage Characteristics of Metal Specimens by Formaldehyde (포름알데히드에 의한 금속시편의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.287-298
    • /
    • 2015
  • The formaldehyde is damage to the metal are known universally. However, the quantification of the damage level and degree of damage is not clear. This study was conducted to test the following steps using a gas corrosion tester, and then evaluated by the optical, chemical and physical measurement. First, it was confirmed the damage level of the metal specimen(silver, copper, iron, lead, brass) by the formaldehyde(0.5, 1, 10, 100, 500ppm). Second, weighted damage to the metal specimens were tested according to the temperature and humidity conditions under damage levels. Third, the damage of accelerated degradation metal specimens were examined under damage levles. As a result, at 500ppm / day, the optical, chemical and physical damage of lead have been identified, the optical damage of all metals are was observed. The optical damage of some specimens were weighted in $25^{\circ}C-50%$, $30^{\circ}C-50%$. Chemical damage to the lead specimen is 2.8 times, 1.3 times were weighted in $30^{\circ}C-80%$, $25^{\circ}C-80%$. Referring to formate ion concentration of the accelerated degradation metal, corrosion products of iron and brass were actived the reaction of the formaldehyde gas, oxide film of lead was blocked the reaction of formaldehyde gas.

Electrochemical Reduction of Carbon Dioxide Using a Proton Exchange Membrane (양이온 교환막을 이용한 이산화탄소의 전기화학적 환원)

  • Kim, Hak-Yoon;Ahn, Sang Hyun;Hwang, Seung Jun;Yoo, Sung Jong;Han, Jonghee;Kim, Jihyun;Kim, Soo-Kil;Jang, Jong Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.216-221
    • /
    • 2012
  • Electrochemical reduction of carbon dioxide has been widely studied by many scientists and researchers. Recently, the production of formic acid, which is expensive but highly useful liquid material, is receiving a great attention. However, difficulties in the electrochemical reduction process and analyzing methods impede the researches. Therefore, it is important to design an adequate system, develop the reduction process and establish the analyzing methods for carbon dioxide reduction to formic acid. In this study, the production of formic acid through electrochemical reduction of carbon dioxide was performed and concentration of the product has been analyzed. Large scale batch cell with proton exchange membrane was used in the experiment. The electrochemical experiment has been performed using a series of metal catalysts. Linear sweep voltammetry (LSV) and chronoamperometry were performed for carbon dioxide reduction and electrochemical analysis using silver chloride and platinum electrode as a reference electrode and counter electrode, respectively. The concentration of formic acid generated from the reduction was monitored using high performance liquid chromatography (HPLC). The results validate the appropriateness and effectiveness of the designed system and analyzing tool.

Transport of Organic Acids through Porous Sulfonated Polystyrene Divinylbenzene Copolymer Membranes (다공성 술폰화 폴리스티렌-디비닐벤젠 공중합체 분리막을 통한 유기산의 이동)

  • 이광재;한정우;조영일
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1991
  • Sulfonated polystyrene-divinylbenzene(PS-DVB) copolymer membranes were prepared using different diluents (toluene, cyclohexane, cyclohexanol), various diluent ratio and DVB contents. And initial fluxes of organic acids were investigated by varying pH and initial concentration. As a results, water content and ion-exchange capacity decreased with increasing DVB concetration. Among used diluents, cyclohexanol was the most efficient for building up the highest water content and ion-exchange capacity. In the experiment of permeation, carboxylic acid such as formic acid and acetic acid showed higher fluxes when pH was lower than pKa and amino add such as L-alanine showed minimum flux when pH was isoelectric value. The relationaship between initial fluxes and initial concentrations has been expressed by saturation kinetics.

  • PDF

Determination of Low Molecular Weight Organic Acids in Pacific Silver Fir Leachates by Using Ion Chromatography (Ion chromatography에 의(依)한 나뭇잎의 저분자량(低分子量) 유기산(有機酸) 분석(分析))

  • Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.22-29
    • /
    • 1993
  • 나뭇잎으로부터 발생되는 저분자량 유기산을 이온크로마토그래피를 이용하여 분석하였다. 이 방법은 자연상태의 나뭇잎 (needle litter)을 유기용매의 추출 없이 그대로 이용할 수 있어서 사용하기에 편리하다. 본 논문에서는 이온 크로마토그래피의 사용방법과 침엽수잎(Pacific Silver Fir)의 부후정도에 따른 유기산의 종류와 농도의 변이를 간략하게 소개한다. 초기의 침엽수잎 여과액으로부터는 $C_2$에서 $C_4$까지의 아세트산(acetic acid), 프로피온산(propionic acid), 옥살산(oxalic acid) 그리고 포름산(formic acid) 등이 주종을 이루지만 부후정도가 커짐에 따라 방향핵을 가진 방향핵 유기산(aromatic organic acid)이 발생한다.

  • PDF

Recovery of Metallic Pd with High Purity from Pd/Al2O3 Catalyst by Hydrometallurgy in HCl (염산 침출용액을 이용한 Pd/Al2O3 촉매에서 고순도 팔라듐 회수)

  • Kim, Ye Eun;Byun, Mi Yeon;Baek, Jae Ho;Lee, Kwan-Young;Lee, Man Sig
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.270-278
    • /
    • 2020
  • Palladium (Pd) has been widely used in various industrial applications such as jewelry, catalyst, and dental materials despite its limited resources. It has been gaining attention to recover Pd with high purity from the spent materials. This study investigated the optimum conditions for the leaching and recovery of metallic Pd. The leaching parameters are HCl concentration, temperature, time, concentration of oxidants, and pulp density. 97.2% of Pd leaching efficiency was obtained in 3 M HCl with 3 vol% oxidants at 80℃ for 60 min. The ratio of hydrogen peroxide to sodium hypochlorite played a critical role in the leaching efficiency due to the supply of Cl- ions in the leachate. Moreover, the complete recovery of Pd in the leachate was achieved at 80℃ with 0.3 formic acid/leachate after adjusting the pH value of 7. This situation was ascribed to the decomposition of formic acid into hydrogen gas and carbon dioxide at 80℃. ICP-AES and XRD characterized the recovered Pd powder, and the purity of the recovered powder was found to be 99.6%. Consequently, the recovered Pd powder with high purity could be used in circuits, catalyst precursors, and surgical instruments.

2, 4, 6-Trinitrotoluene(TNT) Treatment by the Alkaline Hydrolysis (가수분해에 의한 2, 4, 6-Trinitrotoluene(TNT) 처리)

  • Kwon, Bumgun;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.9
    • /
    • pp.69-74
    • /
    • 2012
  • This study investigated the TNT decomposition by the treatment of alkaline hydrolysis. To obtain this objecitive, spectrum shift characteristics, pH effect, kinetics, and product analysis were examined during the alkaline hydrolysis by means of hydroxide ions. At pH = 12, an aqueous solution of TNT was changed into yellow-brown coloring, in which its absorbances were newly increased in a range of wavelength 400-600 nm. From the kinetic data, pseudo-first-order rate constant in a excess of hydroxide ion, in contrast to TNT concentration, was $0.0022min^{-1}$, which means that the reaction rate between TNT and hydroxide ion can be very slow, and that 1,047 min is necessary to achieve a 90% reduction of the initial TNT. In products analyses, nitrite ions and formic acid were mainly produced by the alkaline hydrolysis, nitrate ions and oxalic acid as minor products were generated.

Development and Validation of the Determination of Sorafenib in Human Plasma using Tandem Mass Spectrometry Coupled with Liquid Chromatography (고속액체크로마토그래피 텐덤질량분석기법을 이용한 사람 혈장 내 소라페닙 농도분석법의 개발 및 검정)

  • Park, Daejin;Lee, Sunggon;Kim, Woomi
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1456-1462
    • /
    • 2012
  • Sorafenib is a multikinase inhibitor and an oral anticancer drug approved for the treatment of patients with advanced renal cell carcinoma and those with unresectable hepatocellular carcinoma. The purpose of this study was to develop an efficient method of the determination of sorafenib in human plasma using tandem mass spectrometry coupled with liquid chromatography (LC/MS/MS) and validate the method by the guidelines of the Korean Food and Drug Administration (KFDA). Plasma samples ($100{\mu}l$) were added with chlorantraniliprole as an internal standard and then mixed with the 0.1% formic acid-containing extraction solution composed of isopropyl alcohol and ethyl acetate (1:4, v/v). After centrifugation, the supernatant was concentrated at $45^{\circ}C$ under negative pressure and centrifugal force. The residue was reconstituted with a mobile phase and injected into the HPLC instrument using a reverse phase Waters XTerra$^{TM}$ C18 column (particle size $3.5{\mu}m$). Liquid chromatography was carried out within the run time of 5 min using a mobile phase composed of buffer (0.1% formic acid and 10 mM ammonium formate), methanol, and acetonitrile (1:6:3, v/v/v). The analytes were monitored by tandem mass spectrometry in the multiple reaction monitoring method programmed to detect sorafenib at 'm/z 465.2 ${\rightarrow}$ 252.5' and chlorantraniliprole at 'm/z 484.4 ${\rightarrow}$ 286.2' with positive electrospray ionization mode ($ES^+$). The result showed the proper linearity ($r^2$ > 0.99) over the range of 2,000-5,000 ng/ml with good accuracy (90.7-103.9%) and precision (less than 10%). The newly developed method using LC/MS/MS was validated by the guideline of KFDA and identified as more sensitive compared to the previous methods.