• Title/Summary/Keyword: 폐컴퓨터

Search Result 184, Processing Time 0.022 seconds

Quantitative CT Evaluation for Lung Volume and Density in Dogs (개에서 정량적 컴퓨터단층촬영을 이용한 폐용적과 폐밀도의 평가)

  • Choi, Soo-Young;Lee, In;Jeong, Woo-Chang;Heng, Hock Gan;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.376-381
    • /
    • 2014
  • In this study, we analyzed the computed tomography (CT) measurements of lung volume and density in dogs with relation to body weight, age, sex, and breed. The multi-detector CT examination of the thorax was performed on dogs without respiratory or cardiovascular diseases. Three-dimensional reconstruction of CT images facilitated measurement of lung volume and density. There was a statistical significant correlation between body weight and lung volume (p < 0.0001). Lung density significantly decreased with an increase in body weight (p = 0.0078). However, no correlation was seen between these lung parameters and either sex or age of the dogs. In conclusion, this study shows that body weight is an important factor to consider when interpreting total lung volume and density values measured by quantitative CT. We highlight the need for further study using quantitative CT in identifying the potential effects of sex, age, and disease status on these parameters.

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Remote control CCTV using waste smartphone. (폐 스마트폰을 활용한 원격제어 CCTV)

  • Lee, Hongrae;Yang, Heeseok;Shin, Jeonghun;Choi, Seunghak;Moon, Mikyeong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.89-90
    • /
    • 2015
  • 본 논문에서는 폐 스마트폰을 활용하기 위한 원격제어 CCTV 시스템에 대하여 기술한다. 시스템은 폐 스마트폰용 애플리케이션과 폐 스마트폰을 거치할 수 있는 스마트독, 그리고 사용자용 애플리케이션으로 구성된다. 폐 스마트폰용 애플리케이션은 스마트독을 제어할 수 있고 영상을 전송할 수 있다. 스마트독은 온도, 습도, 적외선 센서와 서보모터가 장착되어 있다. 사용자용 애플리케이션은 영상을 확인할 수 있고 스마트독의 센서 데이터를 전송받을 수 있다. 본 논문에서 제안하는 시스템은 늘어나는 폐 스마트폰을 효율적으로 활용할 수 있고 적은 비용으로 실내 CCTV 환경을 구축할 수 있다는 장점이 있다.

  • PDF

A Study on Computer-Aided Diagnosis System for Interstitial Lung Disease in Chest Radiograph (흉부 영상에서 간질성 폐질환 검출을 위한 컴퓨터지원진단 시스템 연구)

  • 김진철;송종태;이우주;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.316-318
    • /
    • 2003
  • 간질성 폐질환(Interstitial Lung Disease) 컴퓨터지원진단(Computer-Aided Diagnosis: CAD)시스템은 방사선의사들이 흉부 X-ray영상에서 석회화와 섬유화를 탐지하고자 적용하였다. 진단 중에 발생할 수 있는 오진율을 줄이고 간질성 폐질환이 존재하는 폐야에서 이상유무를 판단하여 검출을 표시하도록 하였다. 본 논문에서는 디지털 흉부영상에서의 간질성 폐질환을 검출하기 위해 폐 텍스처(texture)의 물리적 척도를 측정하기 위한 방법을 제안한다. 2차원의 푸리에 변환으로부터 얻어지는 파워스펙트럼(power spectrum) 분석에 기반을 두는 방법으로 각각의 ROI(Region Of Interest)에서 구한 평균제곱자승오차(Root Mean Sguare: RMS)와 파워스펙트럼의 첫 번갠 모멘트(Moment)는 폐 텍스처의 밀도변동의 크기(magnitude)와 섬세함(fineness)을 나타낸다. 실험결과 다양한 간질성폐질환을 가진 비정상 폐 텍스처의 RMS와 첫 번째 모멘트와는 차이가 있었다. 디지텔 흉부영상으로부터 계산되어진 정량화된 텍스처의 척도는 방사선의사의 간질성 폐 질환을 진단함에 효율적인 질환 탐지를 가능하게 하였으며 진단율을 향상시킬 수 있었다.

  • PDF

A Study on the Physical Separation Characteristics of Valuable Metals from the Waste Printed Wiring Boards (물리적 처리에 의한 폐 컴퓨터 기판으로부터 유가금속의 분리선별 특성 연구)

  • 현종영;채용배;정수복
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • Printed wiring boards(PWBs) of the obsolete computers are composed of various organic and inorganic compounds as well as metals and alloys. As convinced that the valuable metals obtained from the PWBs are effectively utilized as secondary resources when recovered by economical methods, in this study, an investigation for characterizing the physical separation techniques is conducted. For the recovery of them, the sockets and chips dismantled from PWBs by scraping and residual resin boards are subjected to the appropriate separation processes according to the physical properties of each part. In the case of crushed socket scraps size ranged from -2.36 mm to +1.18 mm, approximately 97 wt% of the product obtained by magnetic separation consists of metallic compounds. In the case of chip scraps, 97% of Fe-Ni alloy and 95% of Cu metal are recovered by the combined process of air classification and dry magnetic separation in the size range from -2.36 mm to +0.15 mm. Ball milling is adopted in order to improve the removal efficiency of the thin-printed metallic materials on the residual resin boards and approximately 77% of Cu metal is recovered by zigzag separation after ball milling.

Segmentation and Image Fusion using PET/CT Images (PET/CT 영상을 이용한 영역 분리 및 영상 퓨전)

  • Seo, An-Na;Kim, Jee-In
    • Journal of the Korea Computer Graphics Society
    • /
    • v.11 no.2
    • /
    • pp.26-33
    • /
    • 2005
  • 의료기기들 중 기능 영상을 보기 위해 이용되는 PET 장치에서 획득된 결과 영상은 선명하지 않기 때문에, 해부학적 구조와 기능 영상을 동시에 보기 위해서는 선명한 영상을 제공하는 CT 와 PET 장치와 하나로 통합하여 영상을 획득하게 되었다. 그래서 한번의 촬영으로 PET/CT 영상을 얻을 수 있게 된 것이다. 서로 다른 특성을 갖는 이미지를 융합하게 되면 보다 정확한 진단을 내리는데 많은 도움을 준다. 본 논문은 CT 영상에서 폐 영역을 반 자동(Semi-Auto)으로 분리한 후 PET 영상에 자동으로 융합하는 방법을 제안한다. 반 자동 폐 영역 분할을 위해 1 차원 신호 처리 기법과 Seeded Region Growing 기법을 사용한다. 수행된 폐 분리 결과는 몸의 해부학적 구조를 보기 위해 사용되는 CT 영상에서 추출한 폐 영역을 기능을 보기 위한 PET 영상에 퓨전 함으로서 진단 전문가가 보다 정확한 진단을 하는데 도움이 될 것이다. 또한 이러한 기능을 쉽게 구현하고 사용할 수 있도록 시각 프로그래밍 기법을 접목하였다.

  • PDF

Computerized detection of pulmonary nodules in digital chest images (디지털 테스트 영상에서의 폐 노쥴 자동 탐지)

  • Seong, Won;Park, Jong-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.637-639
    • /
    • 2002
  • 일반적으로 방사선 의사들(radialogists)이 폐 노쥴(pulmonary nodule)을 탐지하는 데는 실제적으로 30%의 실패율을 가진다고 알려져 있다. 만약 자동화된 시스템이 체스트 영상에서 의심스런 노쥴들의 위치들을 방사선 의사에게 알려줄 수 있다면 잘못 판단되는 노쥴들의 수를 잠재적으로 줄일 수 있다. 우리는 형태학적 필터들(morphological filters)과 두가지 특징-추출(feature-extraction) 기술들을 포함하는 컴퓨터 자동 처리 시스템을 구현하였다. 본 시스템에서는 첫째로 형태학적 필터 (morphological filtering)처리를 행한다. 이 과정은 원래의 영상에 침식(erosion)과 확장(dilation)을 연이어서 행하는 것으로 처리가 어려운 X 선 영상을 좀 더 다루기 쉬운 상태로 바꿔주는 역할을 하게 된다. 둘째는 일차적으로 노쥴로서 컴퓨터에 선택된 의심 부분에 가해주는 특징-추출 테스트로서 이 작용은 노쥴로 감지되었으나 실제로는 노쥴이 아닌 경우인false-positive 감지들을 줄이기 위해서 사용된다. 그리하여 본 시스템은 노쥴의 정확한 판독이 어려운 폐의 X선 영상에 적용되어 false-positive 들을 효과적으로 줄임으로써 보다 효율적인 폐 노쥴의 탐지를 가능하게 하였다.

  • PDF

Automatic detection of pulmonary nodules in X-ray chest images (폐의 X선 영상에서의 노쥴 자동 탐지 기법)

  • Seong, Won;Park, Jong-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04a
    • /
    • pp.767-770
    • /
    • 2002
  • 일반적으로 방사선 의사들(radialogists)이 폐 노쥴(pulmonary nodule)을 탐지하는 데는 실제적으로 30%의 실패율을 가진다고 알려져 있다. 만약 자동화된 시스템이 체스트 영상에서 의심스런 노쥴들의 위치들을 방사선 의사에게 알려줄 수 있다면 잘못 판단되는 노쥴들의 수를 잠재적으로 줄일 수 있다. 우리는 형태학적 필터들(morphological filters)과 두가지 특징-추출(feature-extraction) 기술들을 포함하는 컴퓨터 자동 처리 시스템을 구현하였다. 본 시스템에서는 첫째로 형태학적 필터(morphological filtering) 처리를 행한다. 이 과정은 원래의 영상에 침식(erosion)과 확장 (dilation)을 연이어서 행하는 것으로 처리가 어려운 X 선 영상을 좀 더 다루기 쉬운 상태로 바꿔주는 역할을 하게 된다. 둘째는 일차적으로 노쥴로서 컴퓨터에 선택된 의심 부분에 가해주는 특징-추출 테스트로서 이 작용은 노쥴로 감지되었으나 실제로는 노쥴이 아닌 경우인 false-positive 갑지들을 줄이기 위해서 사용된다. 그리하여 본 시스템은 노쥴의 정확한 판독이 어려운 폐의 X 선 영상에 적용되어 false-positive 들을 효과적으로 줄임으로써 보다 효율적인 폐 노쥴의 탐지를 가능하게 하였다.

  • PDF

The Compression of Left Main Bronchus Caused by Dilated Descending Aorta After Ligation of PDA (동맥관 개존증 결찰 후 확장된 하행대동맥에 의한 좌측 주기관지 협착)

  • 강정한;박영환;윤영남;김부연;김시호;홍유선;조범구
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.974-977
    • /
    • 2000
  • 유아에서 흔치 않지만, 선천적 혹은 후천적 원인으로 혈관에 의해 기도가 눌릴 수 있다. 8개월 남자 환아가 승모판 성형술, 동맥관 개존증 결찰 후 좌측 폐의 무기폐가 발생하였다. 흉부 컴퓨터 단층 촬영상 동맥관 개존증 결찰 후 남은 비대해진 하행대동맥에 의해 좌측 폐의 무기폐가 발생하였다. 흉부 컴퓨터 단층 촬영상 동맥관 개존증 결찰 후 남은 비대해진 하행대동맥에 의해 좌측 주기관지가 눌리는 소견이 관찰되었다. 결찰 부위를 완전히 분리하고 하행대동맥을 봉합하여 크기를 줄여 기관지 압박을 해결할 수 있었다. 술 후 환자는 특별한 합병증 없이 퇴원하였으며 외래 추적 관찰 중이다.

  • PDF