• Title/Summary/Keyword: 폐질환진단

Search Result 173, Processing Time 0.019 seconds

Effect of Nasal Continuous Positive Airway Pressure after Early Surfactant Therapy in Moderate Respiratory Distress Syndrome (중등도 신생아 호흡 곤란 증후군에서 폐 표면 활성제 조기 투여 후 Nasal CPAP의 치료 효과)

  • Kim, Eun Ji;Kim, Hae Sook;Hur, Man Hoe;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1204-1212
    • /
    • 2002
  • Purpose : Early surfactant therapy with either gentle ventilation, high-frequency ventilation or aggressive weaning of mechanical ventilation are principles for the treatment of respiratory distress syndrome(RDS). We studied to determine the accessibility of noninvasive nasal continuous positive airway pressure(CPAP) rather than mechanical ventilation by invasive intubation after early surfactant therapy. Methods : The study group consisted of 14 infants who were born and diagnosed with moderate respiratory distress syndrome and received early surfactant therapy with nasal CPAP of PEEP 5-6 cm $H_2O$ within two hours after birth in the Fatima neonatal intensive care unit for two years from January 1999 to August 2001. The control group consisted of 15 infants who were diagnosed with the disease and could be weaned from mechanical ventilator within five days after birth during the same period. Results : The characteristics, the severity of clinical symptoms and laboratory findings in the two groups at birth showed no significant difference. Neither did the interim analysis of laboratory data in two groups. Of 14 infants in the study group who received nasal CPAP after early surfactant therapy, only two infants showed weaning failure with this therapy. In the response cases, duration of CPAP was five days and mean airway pressure was $5.4{\pm}0.5cm$ $H_2O$. Two had the complication of CPAP with abdominal distension. Final complications and outcomes in the two groups showed no signifcant difference(P>0.05). Conclusion : The clinical courses in the two groups showed no significant difference. Therefore, we suggest that early surfactant therapy with noninvasive nasal CPAP is a simple and safe method rather than aggressive weaning after invasive mechanical ventilation in moderate respiratory distress syndrome.

Clinical Application of Serum CEA, SCC, Cyfra21-1, and TPA in Lung Cancer (폐암환자에서 혈청 CEA, SCC, Cyfra21-1, TPA-M 측정의 의의)

  • Lee, Jun-Ho;Kim, Kyung-Chan;Lee, Sang-Jun;Lee, Jong-Kook;Jo, Sung-Jae;Kwon, Kun-Young;Han, Sung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.785-795
    • /
    • 1997
  • Background : Tumor markers have been used in diagnosis, predicting the extent of disease, monitoring recurrence after therapy and prediction of prognosis. But the utility of markers in lung cancer has been limited by low sensitivity and specificity. TPA-M is recently developed marker using combined monoclonal antibody of Cytokeratin 8, 18, and 19. This study was conducted to evaluate the efficacy of new tumor marker, TPA-M by comparing the estabilished markers SCC, CEA, Cyfra21-1 in lung cancer. Method : An immunoradiometric assay of serum CEA, sec, Cyfra21-1, and TPA-M was performed in 49 pathologically confirmed lung cancer patients who visited Keimyung University Hospital from April 1996 to August 1996, and 29 benign lung diseases. Commercially available kits, Ab bead CEA (Eiken) to CEA, SCC RIA BEAD (DAINABOT) to SCC, CA2H (TFB) to Cyfra2H. and TPA-M (DAIICHI) to TPA-M were used for this study. Results : The mean serum values of lung cancer group and control group were $10.05{\pm}38.39{\mu}/L$, $1.59{\pm}0.94{\mu}/L$ in CEA, $3.04{\pm}5.79{\mu}/L$, $1.58{\pm}2.85{\mu}/L$ in SCC, $8.27{\pm}11.96{\mu}/L$, $1.77{\pm}2.72{\mu}/L$ in Cyfra21-1, and $132.02{\pm}209.35\;U/L$, $45.86{\pm}75.86\;U/L$ in TPA-M respectively. Serum values of Cyfra21-1 and TPA-M in lung cancer group were higher than control group (p<0.05). Using cutoff value recommended by the manufactures, that is $2.5{\mu}/L$ in CEA, $3.0{\mu}/L$ in Cyfra21-1, 70.0 U/L in TPA-M, and $2.0{\mu}/L$ in SCC, sensitivity and specificity of lung cancer were 33.3%, 78.6% in CEA, 50.0%, 89.7% in Cyfra21-1, 52.3%, 89.7% in TPA-M, 23.8%, 89.3% in SCC. Sensitivity and specificity of nonsmall cell lung cancer were 36.1%, 78.1% in CEA, 50.1%, 89.7% in Cyfra21-1, 53.1%, 89.7% in TPA-M, 33.8%, 89.3% in SCC. Sensitivity and specificity of small cell lung cancer were 25.0%, 78.5% in CEA, 50.0%, 89.6% in Cyfra21-1, 50.0%, 89.6% in TPA-M, 0%, 89.2% in SCC. Cutoff value according to ROC(Receiver operating characteristics) curve was $1.25{\mu}/L$ in CEA, $1.5{\mu}/L$ in Cyfra2-1, 35 U/L in TPA-M, $0.6{\mu}/L$ in SCC. With this cutoff value, sensitivity, specificity, accuracy and kappa index of Cyfra21-1 and TPA-M were better than CEA and SCC. SCC only was related with statistic significance to TNM stages, dividing to operable stages(TNM stage I to IIIA) and inoperable stages (IIIB and IV) (p<0.05). But no tumor markers showed any correlation with significance with tumor size(p>0.05). Conclusion : Serum TPA-M and Cyfra21-1 shows higher sensitivity and specificity than CEA and SCC in overall lung cancer and nonsmall cell lung cancer those were confirmed pathologically. SCC has higher specificity in nonsmall cell lung cancer. And the level of serum sec are signiticantly related with TNM staging.

  • PDF

The Effect of Pleural Thickening on the Impairment of Pulmonary Function in Asbestos Exposed Workers (석면취급 근로자에서 늑막비후가 폐기능에 미치는 영향)

  • Kim, Jee-Won;Ahn, Hyeong-Sook;Kim, Kyung-Ah;Lim, Young;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.923-933
    • /
    • 1995
  • Background: Pleural abnormality is the the most common respiratory change caused by asbestos dust inhalation and also develop other asbestos related disease after cessation of asbestos exposure. So we conducted epidemiologic study to investigate if the pleural abnormality is associated with pulmonary function change and what factors are influenced on pulmonary function impairment. Methods: Two hundred and twenty two asbestos workers from 9 industries using asbestos in Korea were selected to measure the concentration of sectional asbestos fiber. Ouestionnaire, chest X-ray, PFT were also performed. All the data were analyzed by student t-test and chi-square test using SAS. Regressional analysis was performed to evaluate important factors, for example smoking, exposure concentration, period and the existence of pleural thickening, affecting to the change of pulmonary function. Results: 1) All nine industries except two, airborn asbestos fiber concentration was less than an average permissible concentration. PFT was performed on 222 workers and the percentage of male was 88.3%, their mean age was $41{\pm}9$ years old, and the duration of asbestos exposure was $10.6{\pm}7.8$ yrs. 2) The chest X-ray showed normal(89.19%), pulmonary Tb(inactive)(2.7%), pleral thickening (7.66%), suspected reticulonodular shadow(0.9%). 3) The mean values of height, smoking status, concentration of asbestos fiberwere not different between the subjects with pleural thickening and others, but age, cumulative pack-years, the duration of asbestos exposure were higher in subjects with pleural thickening. 4) All the PFT indices were lower in the subjects with pleural thickening than in the subjects without pleural thickening. 5) Simple regression analysis showed there was a significant correlation between $FEF_{75}$ which is sensitive in small airway obstruction and cumulative smoking pack-years, the duration of asbestos exposure and the concentration of asbestos fiber. 6) Multiple regression analysis showed all the pulmonary function indices were decreased as the increase of cumulative smoking pack-years and especially in the indices those are sensitive in small airway obstruction. Pleural thickening was associated with reduction in FVC, $FEV_1$, PEFR and $FEF_{25}$. Conclusion: The more concentration of asbestos fiber and the more duration of asbestos exposure, the greater reduction in $FEF_{50}$, $FEF_{75}$. Therefore PFT was important in the evaluation of early detection for small airway obstruction. Furthermore pleural thickening without asbesto-related parenchymal lung disease is associated with reduction in pulmonary function.

  • PDF