• Title/Summary/Keyword: 폐용적

Search Result 103, Processing Time 0.027 seconds

Study on dose comparison using X-Jaw split in VMAT treatment planning for left breast cancer including supraclavicular lymph nodes. (쇄골 상부 림프절을 포함하는 왼쪽 유방암의 VMAT 치료계획시 X-Jaw split을 이용한 선량비교에 관한 연구)

  • Kim, Hak Jun;Lee, Yang Hoon;Min, Jae Soon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose : The usability of X-Jaw split VMAT was evaluated by comparative analysis of the dose distribution between the treatment plan divided by X-Jaw and Full field VMAT treatment plan in left breast cancer treatment including supraclavicular lymph nodes. Materials and Methods : 10 patients with left breast cancer, including supraclavicular lymph nodes, were simulated using vacuum cushion, and 2 Full field Arc VMAT and 4 X-Jaw split Arc VMAT were planned The treatment plan was designed to include more than 95% of the Planning Target Volume (PTV) and to be minimally irradiated in the surrounding Organ at risk (OAR). Dose analysis of PTV and OAR was performed through dose volume histogram (DVH). Results : The Full field VMAT treatment plan and the X-Jaw split VMAT treatment plan of 10 patients were expressed as average values and compared. The difference between the two treatment plans was not large, with a Conformity index (CI) of 1.05±0.04, 1.04±0.03, and a Homogeneity index (HI) of 1.07±0.008, 1.07±0.009. For OAR, V5 in the left lung is 56.1±6.50%, 50.4±6.30%, and V20 is 20.0±4.15%, 13.52±3.61%. Compared to Full field VMAT, V5 decreased by 10.0% V20 by 32.6% in X-Jaw split VMAT. The V30 of the heart is 3.68±1.85%, 2.23±1.52%, and the Mean dose is 8.93±1.65 Gy, 7.67±1.52 Gy. In the X-Jaw split VMAT, V30 decreased by 39.3% and the Mean dose decreased by 14.1%. The left lung and heart, which are normal tissues, were found to have a statistical significance of that p-value is less than 0.05. Conclusion : In the case of left breast cancer treatment, which includes Supraclavicular lymph nodes with a large PTV volume and a length of X Jaw of 15 cm or more, the X-Jaw split VMAT shows improved dose distribution, which can reduce radiation dose of OAR such as lungs and heart, while maintaining similar PTV coverage with HI and CI equivalent to Full field VMAT. It is thought to be effective in reducing radiation complications.

The Correlation of Dyspnea and Radiologic Quantity in Patients with COPD (만성폐쇄성폐질환 환자에서 호흡곤란과 영상학적 정량과의 상관관계)

  • Jung, Eun Jung;Kim, Yang Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong Hoon;Kim, Do Jin;Park, Choon Sik;Hwang, Jung Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.288-294
    • /
    • 2009
  • Background: A lung hyperinflation, or air trapping, caused by expiratory flow-limitation contributes to dyspnea in patients with chronic obstructive pulmonary disease (COPD). Forced expiratory volume in 1 second ($FEV_1$) has served as an important diagnostic measurement of COPD, but does not correlate with patient-centered outcomes such as dyspnea. Therefore, this study was performed to investigate the role of radiologic quantity in evaluating the dyspnea in patients with COPD by measuring lung hyperinflation in chest x-ray and high resolution chest tomography (HRCT). Methods: Fifty patients with COPD were enrolled in this study. Their subjective dyspnea score (modified Borg scale dyspnea index), spirometry, and lung volume were measured. Simultaneous hyperinflations of chest x-ray score ("chest score") and degree of emphysema of HRCT ("HRCT score") were measured. The "chest score" were composed of lung length, retrosternal space width, and height of the arc of the diaphragm and "HRCT score" were composed of severity and extent of emphysema. Results: The mean age of patients was 69 years old and their mean $FEV_1$ was 51.7%. The Borg score significantly correlated with parameters of spirometry and lung volume, including FVC, $FEV_1$, $FEV_1$/FVC, RV, RV/TLC, and DLCO. The Borg score correlated well with "HRCT score", but did not correlate with "chest score". Also, the Borg scale correlates inversely with body mass index. Conclusion: The quantity of emphysema on chest HRCT may serve as an objective marker of dyspnea in patients with COPD.

The Usefulness of Integrated PET/CT Simulator for Non-Small Cell Lung Cancer Using the F-18 Fluoro-2-deoxyglucose (FDG) (포도당 유도체 불소화합물(FDG)을 이용한 비소세포폐암의 Integrated PET/CT 전산화 모의치료기에 대한 유용성 평가)

  • Na, Jong Eok;Suh, Jeong Nam;Kim, Jin Soo;Kim, Dae Seob;Hong, Dong Ki;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To evaluate the usefulness of Integrated PET/CT and compare the gloss tumor volume (GTV) identified on CT, PET, PET/CT to that obtained from fluorodeoxyglucose (FDG). Materials and Methods: This experimental study was obtained using GE Discovery 690 (General Electric Healthcare, Milwaukee, MI, USA) PET/CT simulator with Gammex Laser System for five non-small cell lung cancer (NSCLC) patients. In order to increase the reproducibility of the patient setup, We have to fixed to patients using the Extended Wing Board. GTV delineation was painted using the EclipseTM ver.10 contouring program for CT, PET, PET/CT images. And then, We were to compare the changes in the GTV. Results: These results are drawn from 5 patients who have atelectasis or pneumonitis. Compared to CT defined GTV, PET was decreased by 10.5%, 11.8% and increased by 67.9%, 220%, 19.4%. PET/CT was decreased by 7.7%, 6.7%, 28% and increased by 232%, 24%. Conclusion: We were able to determine the usefulness of PET/CT simulator for NSCLC. PET/CT simulator in radiation therapy is useful to define the target volume and It is possible to delineate Objective and accurate target volume. It seems to be applicable to other areas in the near future.

  • PDF

A Study on the Quality Properties When Applying Recycled Aggregate Concrete for the Construction Standard Mitigation (건축기준 완화를 위한 순환골재 콘크리트 적용 시의 품질 특성 연구)

  • Woo, Gyeong-Sub;Kim, Jung-Ho;Lee, Sea-Hyun;Oh, Jung-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.63-69
    • /
    • 2020
  • The volume of construction waste material from the entire waste material volume in Korea is approximately 47.3% to take the biggest ratio, and from them, the waste concrete takes up approximately 62.8% that recycling is an urgent issue to address. Therefore, the government recommends more diverse and broader facilitation of the recycled aggregate in order to promote recycling the construction waste materials. In addition, when using concrete recycled aggregate in building, building standard such as floor area ratio and building height are being mitigation. The standard is a condition that mitigation the floor area ratio by up to 15% when using up to 25% of concrete recycled aggregate. Therefore, this study reviewed the relaxation of construction of construction standards when using concrete recycled aggregate in order to actively recommend the use of concrete recycled aggregate. And using the recycled coarse aggregate among the recycled aggregate, the appropriate mixing time in the batch plant according to the substitution rate was derived. In addition, using recycled aggregate admixture in order to improve the drying shrinkage, did comparative analysis about physical and mechanical property of concrete.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Objective in Vivo Quantification of Emphysema by Thin-Section CT: Correlation with Physiologic Findings (고해상 전산화단층촬영을 이용한 폐기종의 정량적 분석: 폐기능 검사와의 비교)

  • Lee, Jee-Young;Lee, Kye-Young;Choi, Eun-Kyoung;Kim, Sang-Joon;Choi, Young-Hi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.992-999
    • /
    • 1998
  • Background: To correlate the emphysema score for quantification of the overall extent of emphysema in both lungs by CT with physiologic fingings and to get more objective and simple method to assess the extent of emphysema. Method: Thin-section CT and pulmonary function test(PFT) were performed in 17 patients with emphysema (all males, mean age, 62 years). Emphysema score was obtained as percentage of emphysematous lung area, dividing the total area of the emphysema(voxels with attenuation value less than -880, -900, -920HU, respectively) by the overall area of both lungs(voxels with attenuation value less than -400HU) with highlighting voxels using "Density mask" program. Emphysema score was calculated from whole lung(ESV) and 5 representative scans(ESR) using "Density mask", Visual emphysema score(ESV) was obtained by visual assessment from 5 representative scans. Correlation of these emphysema scores(ESW, ESR, ESV) and physiologic findings were performed, comparing the ESW with ESR and ESV. Results: ESW had correlation with DLCO(r=0.53-0.64) and $FEV_1/FVC$(r=0.42-0.57) among PFT parameters. ESR had good correlation with ESW and with PFT parameters as well. ESV did not correlate with PFT parameters except DLCO. Conclusion: CT quantification of emphysema using "density mask" correlated well with physiologic findings. To assess the severity of emphysema, both ESW and ESR are more reliable than ESV, and ESR is recommended in routine practice as it is objective, simple and reliable.

  • PDF

Effect of the Changing the Lower Limits of Normal and the Interpretative Strategies for Lung Function Tests (폐기능검사 해석에 정상하한치 변화와 새 해석흐름도가 미치는 영향)

  • Ra, Seung Won;Oh, Ji Seon;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae Man;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.129-136
    • /
    • 2006
  • Background: To interpret lung function tests, it is necessary to determine the lower limits of normal (LLN) and to derive a consensus on the interpretative algorithm. '0.7 of LLN for the $FEV_1$/FVC' was suggested by the COPD International Guideline (GOLD) for defining obstructive disease. A consensus on a new interpretative algorithm was recently achieved by ATS/ERS in 2005. We evaluated the accuracy of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases, and we also determined the effect of the new algorithm on diagnosing ventilatory defects. Methods: We obtained the age, gender, height, weight, $FEV_1$, FVC, and $FEV_1$/FVC from 7362 subjects who underwent spirometry in 2005 at the Asan Medical Center, Korea. For diagnosing obstructive diseases, the accuracy of '0.7 of LLN for the $FEV_1$/FVC' was evaluated in reference to the $5^{th}$ percentile of the LLN. By applying the new algorithm, we determined how many more subjects should have lung volumes testing performed. Evaluation of 1611 patients who had lung volumes testing performed as well as spirometry during the period showed how many more subjects were diagnosed with obstructive diseases according to the new algorithm. Results: 1) The sensitivity of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases increased according to age, but the specificity was decreased according to age; the positive predictive value decreased, but the negative predictive value increased. 2) By applying the new algorithm, 34.5% (2540/7362) more subjects should have lung volumes testing performed. 3) By applying the new algorithm, 13% (205/1611) more subjects were diagnosed with obstructive diseases; these subjects corresponded to 30% (205/681) of the subjects who had been diagnosed with restrictive diseases by the old interpretative algorithm. Conclusion: The sensitivity and specificity of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases changes according to age. By applying the new interpretative algorithm, it was shown that more subjects should have lung volumes testing performed, and there was a higher probability of being diagnosed with obstructive diseases.

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Effect of the Application of Residual Food Compost on Growth of Red Pepper(Capsicum annuum L.) and Physicochemical Properties of soil (남은 음식물 퇴비 시용에 따른 토양의 이화학성 변화와 고추생육에 미치는 영향)

  • Yu, Young-Seok;Chang, Ki-Woon;Lee, Ji-Whan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.4
    • /
    • pp.81-88
    • /
    • 2001
  • This experiment was carried out to evaluate the effect of residual food compost application on plant growth and physicochemical properties of soil when residual food compost made from the composting process as part of organic waste recycling was applied in soil as variable rate. The treatments were composed non-fertilizer treatment, control treatment applied with pig compost $20Mg(D.W.)ha^{-1}$, and residual food compost treatments each of applied with 20, 40, 60, $80Mg(D.W.)ha^{-1}$ and were randomized complete block design with three replication. Soil pH after experiment was more increased as more increase application of residual food compost. Other chemical properties of soil including EC were also showed the similar results. The plant growth in treatments applied much of residual food compost at the early growth stage was very damaged and these results were proved at the first growth measurement. Production of the red pepper especially reduced in treatments taken growth demage at the early stage and that of $20Mgha^{-1}$ treatment almost same as control treatment. Bulk density was reduced but porosity was increased according to increase of residual food compost application. Considering the reduction of red pepper production and the demage of growth at the early stage by plenty of salt and water soluble application volume of residual food compost was not permitted over of $30Mgha^{-1}$. Additively, to settle the application volume of residual food compost and to evaluate the plant growth and changes of physicochemical properties of soil, the results taken from continual applying is concluded more important than single application.

  • PDF