• Title/Summary/Keyword: 폐수처리공정

Search Result 644, Processing Time 0.027 seconds

The Single- and Two-Phase Anaerobic Digestion of Food Waste Effluent (단상 및 이상혐기소화공정을 이용한 음폐수의 바이오에너지화)

  • HwangBo, Jun-Kwon;Seo, Jae-Gun;Yoon, Heui-Chul;Park, Hyeon-Gun;Lee, Bo-Won
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 2011
  • The anaerobic digestion of food waste effluent through single- and two-phase process was estimated and compared in this study. The treatment efficiencies for total solid(TS), volatile solid(VS), tCOD(total COD) and sCOD(soluble COD) were invariably higher in the single-phase process, which was accounted for by the fact that the treatment efficiency of organic wastes usually showed an inverse relationship with organic loading rate in the anaerobic digestion. In fact, the organic loading rate was lower for single-phase process. The concentration of tCOD were significantly lower in two-phase process but much more biogas was produced, compared to single-phase anaerobic digestion process, which might be explained partly by the relatively higher stability of two-phase process resulting from the separation of acid phase from methane phase.

염색폐수처리를 위한 막분리공정의 문제점

  • 노수홍;안승호;최광호;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.10a
    • /
    • pp.76-76
    • /
    • 1992
  • 본 연구의 목적은 국내 섬유산업에서 문제시되는 염색폐수처리에 막분리공정의 적용가능성과 문제점을 실험실규모와 pilot 규모의 실험을 통하여 규명하는 것이다. 염색폐수는 섬유의 가공공정에 따라 염료, 분산제, 정염제, 반응제 등 다양한 유기물질과 무기염을 함유하며 온도가 10-90$\circ$C로 높은 것이 특징이다. 본 연구에서는 2종류의 Nanofiltration: NF40, XU45; 두종류의 복합막; BW30, SW30HR; 2종류의 Cellulose Acetate 비대칭막의 평막 Sample을 사용하여 합성염색폐수의 배제율과 압력변화에 따른 투과수에 미치는 영향을 조사하였다. 실제 혼합염색폐수의 처리는 2개의 2.5"$\times$ 40" Nanofiltration 모듈을 장착한 Pilot 장치를 염색단지 종합처리장에 설치하여 3개월에 걸쳐 시행하였다. 현재까지 얻어진 실험결과에 의하면 전처리공정의 효율롸를 통해 부유물질에 의한 Fouling을 최소화하고 폐수의 성분분석과 사용된 막의 표면분석을 통한 체계적인 조사가 필요하다. 염색폐수처리에 막분리공정이 기존처리방법과 비교하여 경제성을 가지려면 효율적인 막세척방법을 개발하여 투과율의 감소를 최소화시켜야 한다.

  • PDF

Temperature Prediction for the Wastewater Treatment Process using Heat Transfer Model (열전달 모델을 이용한 폐수처리공정의 온도 예측)

  • Rho, Seung-Baik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1795-1800
    • /
    • 2014
  • The temperature change in the biologically activated sludge wastewater treatment process was predicted using the heat transfer model. All incoming and outgoing heats in wastewater treatment processes were considered. Incoming heats included the solar radiation heat, the heat from impeller mechanical energy, and the biochemical heat in the aeration process. Outgoing heats comprised the radiation heat from the waste itself, the heat of vaporization and surface aeration, the wind convection heat and the conduction heat between the surface and aerator. All heats were used as an input to the existing empirical heat transfer model. The heat transfer model of wastewater treatment processes is presented also. To test the validity of the heat transfer model, the operating conditions of the actual wastewater treatment plant were used. The temperatures were compared with the model temperatures. Model predictions were consistent within the $1.0^{\circ}C$.

막분리공정을 이용항 폐수처리 및 회수

  • 김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.97-119
    • /
    • 1993
  • 폐수처리 분야에 대한 막분리기술의 적용은 산업 전분야에서 그 성능을 입증받고 널리 활용되고 있는 단계이다. 막분리 기술은 단순히 폐수를 처리한다는 개념이 아니라 폐수중에 함유된 유효물질을 회수하여 재사용한다는 점과 폐수중의 물을 높은 수율로 회수하여 재사용한다는 측면, 폐수 오염원의 부하를 크게 줄여준다는 측면에서 많은 잇점을 가지고 있다. 이러한 특징은 각 분야의 제조공정을 "Closed-loop system화" 및 "Zero Discharge" 개념으로 운전함으로써 환경오염의 방지와 더불어 자원의 재활용에 의한 원가절감 효과를 가져올 수 있게 하였다.절감 효과를 가져올 수 있게 하였다.

  • PDF

Study on the Efficient Operation of Public Wastewater Treatment Facilities in Bukpyeong Industrial Complexes (북평산업단지 공공폐수처리시설의 효율적 운영에 관한 연구)

  • Park, Woon Ji;Shim, Jung Min;Choi, Yong Hun;Lee, Gwan Jae;Lim, Kyoung Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.425-425
    • /
    • 2021
  • 북평산업단지내 공공폐수처리시설(6,500톤/일)의 가동률은 30% 이하로 매우 저조하며, 폐수배출업체는 29개소로 그 수가 적어 배출오염부하량 비율에 따른 처리비용이 일부 업체의 경우 과도하게 부과되고 있는 실정이다. 입주업체 운영비용 부담을 저감하기 위해 해당 지자체에서는 운영비용의 65% 이내에서 일정금액을 지원하고 있으나, 동일업종에 대한 원인자비용부담금 비율의 경우, 동해시 A업체는 30.18%로 타 지역 B업체의 4.83% 보다 높은 것으로 나타났으며, 지자체 지원금을 제외한 순수 처리부과금의 경우 A업체가 2배 이상 큰 것으로 나타났다. 이에 북평산업단지 공공폐수처리시설의 전체 운영비 절감을 위한 효율적인 운영방안 마련이 필요하다. 따라서 본 연구에서는 북평산업단지내 공공폐수처리시설의 운영 및 관리현황을 검토하여 효율적인 운영방안을 제시하고자 하였다. 현재 운영시설에 대한 현황을 파악하고 관련 법률 및 계획등을 검토한 결과, 북평산단 지역은 하수처리 구역이 아닌 공공폐수처리구역으로 산업폐수의 공공하수도처리시설 연계처리 지침에 따라 인근 공공하수처리시설과의 연계처리가 불가한 것으로 나타났다. 또한, 환경부에서는 가동률이 저조한 처리시설에 대해서는 시설개선을 통한 방안을 제시하고 있어 현 처리시설의 공정개선을 통한 운영비 절감방안이 가장 효율적인 것으로 판단되었다. 이에, 현재 생물 반응조 후단에서 운영 중인 가압 부상조에 새로운 배관을 설치하여, 최초 침전지 유출수를 가압부상조 처리 후, 생물 반응조로 유입하고, 최종 침전 후 총인을 제어 할 수 있는 약품투입 시설을 설치하는 공정 개선 방안을 제시하였다. 이처럼 생물 반응조 이전에 가압부상조를 설치하고, 후단 가압 부상조 미운영시 공정개선 전·후에 따른 총 슬러지 발생량은 24.2%, 탈수케익 처리비용은 27.6% 절감할 수 있는 것으로 산정되었으며, 전체 처리시설에 대한 총 운영비 감소율은 13.4%로 분석되었다.

  • PDF

Treatment of Textile Wastewater by Membrane-Bioreactor Process (막-생물반응조 공정을 이용한 염색폐수의 처리)

  • 강민수;김성수;황규대;강종림
    • Membrane Journal
    • /
    • v.7 no.4
    • /
    • pp.175-182
    • /
    • 1997
  • Membrane-bioreactor process which combines anaerobic-aerobic bioreactor and membrane process, was used to remove refractory organic susbstances and dye molecule in textile wastewater effectively. Direct feeding of raw feed water to membrane process caused serious fouling on membrane. On the other hand, pretreated feed by bioreactor before the membrane process remarkably reduced the fouling and prolonged the membrane life. Removal efficiency and fouling were more dependent on the material property of the membrane rather than the membrane pore size and structure. Operation mode of hollow fiber membrane module and linear velocity in the hollow fiber influenced the ramoval efficiency and the water flux of the membrane. The combined membrane- bioreactor process was more effective in treating the textile wastewater than each single process.

  • PDF

The Anaerobic Biodegradability and Methanogenic Toxicity of Pulping Wastewaters (펄프페수의 혐기성 생분해능 및 메탄 생성균의 독성에 관한 연구)

  • 박종안;허준무;장봉기
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.70-79
    • /
    • 1998
  • 본 실험의 목적은 다양한 펄프제조 조건과 여러 형태의 리그노 셀루로우스 성분이 펄프폐수의 혐기성 생분해에 미치는 영향을 규명하는 것이다. 실험에 사용된 폐수는 일반적으로 펄프 제조시에 발생되는 폐수를 대상으로 하였으며, 펄프제조 조건은 TMP공정과 소다 펄프공정을 적용하였다. 혐기성 생분해 가능성 시험 및 독성실험은 $35\pm 2\circ$C의 중온상태에서 입상슬러지를 식종물질로 사용한 회분식 반응조를 이용하였다. TMP공정의 배출되는 폐수는 산으로의 전환율이 총 COD기준으로 68-87%로 매우 높은 혐기성 생분해 가능성을 보였다. 그리고 TMP공정폐수는 일반적으로 제지폐수 처리시 독성농도라고 알려진 농도에서도 메탄생성균에 독성을 주지 않았고, 또한 COD 10g/l의 농도에서도 처리에 저해가 일어나지 않았다. 반면에, 알카리성 상태에서 준비된 펄프폐수의 경우는 생분해성이 매우 낮아서 대략 50%정도의 산전환율을 보였으며, 메탄생성균에 상당한 저해를 주었다. 메턴생성균의 활성도에 50%저해를 주는 농도는 2.1~5.4 gCOD/l였다. 알카리성 펄프폐수의 독성에 대한 추가 실험결과 펄프내 wood resin이 산이나 중성 pH부근에서는 잘 용해가 되지 않고 알카리성 상태에서 쉽게 용해되어 메탄생성균에 저해를 나타내는 것으로 밝혀졌다. 따라서 펄프제조시 나무성분이 알카리성분과 접촉할 경우 후속하는 혐기성 처리공정의 메탄생성균에 심각한 저해를 줄 수 있다.

  • PDF

Efficient Spent Sulfidic Caustic wastewater treatment using Adsorption Photocatalysis System (흡착광산화 시스템을 이용한 효과적인 SSC 페수처리)

  • Kim, Jong Kyu;Lee, Min Hee;Jung, Yong Wook;Joo, Jin Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.520-520
    • /
    • 2016
  • 석유 화학공장에서 발생하는 spent sulfidic caustic (SSC) 폐수는 액화석유가스(LPG)나 천연가스(NG)의 정제과정에서 발생되는 것으로 고농도의 sulfide와 cresylic, phenolic 그리고 mercaptan 등이 포함된 독성과 냄새를 유발하는 물질이다. 이러한 물질들은 LPG나 NG의 정제과정에서 높은 산도를 가진 휘발성 황화합 물질들을 제거하기 위해 사용된 NaOH가 $H_2S$와 반응하여 발생하는 것이다. 진한 갈색 또는 검은색을 띄는 SSC 폐수는 12 이상의 높은 pH를 가지고 있으며 5~12 wt%의 높은 염분도를 가지고 있다. 또한 강한 부식성과 독성을 가진 황화합물의 농도가 1~4 wt%이며, 방향족 탄화수소 물질 (i.e. methanethiol, benzene, tolune and phenol)들도 다량 함유되어 있다. 따라서 이러한 유해 물질들은 기존의 하수처리 공정으로 방류하기 전에 완벽하게 처리해야만 하수처리 공정의 오염 부하량을 줄일 수 있다. 습식산화공정은 SSC 폐수를 처리하기 위해 흔히 사용되고 있는 물리-화학적 처리 공정이지만 고비용, 고에너지가 필요하며, 고온 및 고압에서만 작동되어 안전상의 문제점을 갖고 있다. 또한 습식산화공정을 거친 폐수는 배출허용기준을 만족하기 위해 생물학적 2차 처리가 반드시 필요하다. 철-과산화수소를 이용하는 펜톤산화 공정, 그리고 sulfide를 sulfate로 전환시키는 생물학적 처리 공정은 황화합물의 완전한 무기물화가 힘들며, 현장 적용 시 기술적 경제적 부담이 크다. 이러한 단점을 극복하고, SSC 폐수를 효과적으로 처리하기 위해 본 연구는, 높은 흡착력과 광산화력을 가진 흡착광산화 반응 시스템(Adsorption Photocatalysis System, APS)을 개발하였다. APS는 SSC 폐수를 시스템 내부로 유입하여 수중의 오염물질을 흡착광산화제로 구성된 반응구조체가 흡착하고, 흡착된 오염물질을 UV에너지와 이산화티타늄 광촉매의 광화학반응에 의해 최종적으로 무해한 물질로 환원시키는 폐수처리시스템이다. APS의 반응구조체는 태양에너지 및 인공에너지원에 의해 활용 가능하며, 난분해성 유기화합물질을 물과 이산화탄소로 분해할 수 있는 친환경적이고 경제적인 소재로서 널리 쓰이고 있는 이산화티타늄 광촉매와 화력발전소의 높은 소성온도에 의해 연소된 후 발생되는 bottom ash를 이산화티타늄의 지지체로 사용하여 높은 흡착력과 광촉매 산화력을 가진 복합물이다. 개발된 APS에 의해 SSC 폐수를 처리한 결과, COD 86.1%, 탁도 98.4%, sulfide 99.9%의 높은 처리효율을 보여주고 있다. 따라서 본 연구를 통해 개발된 APS는 강한 부식성과 독성 그리고 높은 농도를 가지고 있는 SSC 폐수를 효과적으로 처리할 수 있다.

  • PDF

Treatment of dyeing wastewater using Moving Bed Bioractor (부유메디아 생물막 공정을 이용한 염색폐수처리)

  • Shin, Dong-Hoon;Lee, Sang-Hun;Ryu, Seung-Han;Park, Jun-Hyung;Jo, Seog-Jin
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.110-110
    • /
    • 2011
  • 염색공업 폐수는 그 성분이 일반적으로 매우 복잡하며, 작업공정의 가동 사항에 따라 수질 변동이 큰것이 특징으로, 각 공정에서 배출되는 염료, 보조화학물질, PVA(Polyvinyl alchol), 전분, wax 등이 포함되어 있으며 pH가 높고, 색도로 인해 하천에 방류될 경우 확산성이 높아 미생물에 의한 자정작용을 방해하여 하천의 수중생태계를 파괴할 우려가 있다. 이러한 염색산업에서 발생하는 폐수는 일반적으로 응집침전, 부상분리법 등의 전처리한 후 활성오니공정으로 처리하는 방법이 널리 이용되고 있으나, 이들 처리공정으로는 폐수 속에 포함되어 있는 다양한화학적 구조의 색소성분 및 유해물질을 완벽하게 제거하는 것이 어려운 실정이다. 유기물 함량이 높은 염색폐수를 처리하기 위해 제안된 기술로는 산소활성슬러지법, 유동상 및 고정상 생물막법, 포괄고정화법 등이 있다. 이러한 기술들중 기존의 처리공정을 증축없이도 처리효율을 높일 수 있는 방법으로 담체를 이용한 부유메디아 생물막공정(Moving-Bed BioReactor, MBBR)이 있다. 이공정은 미생물이 부착, 성장할 수 있는 공극율과 비표면적이 큰 담체를 이용하므로 반응조내의 부유 미생물 뿐만 아니라 담체에 고농도로 부착된 부착 미생물에 의해서도 유기물을 제거하기 때문에 다른 공정들에 비해 처리효율이 뛰어나고 기존의 활성슬러지 공정에 비해 갑작스러운 부하변동 및 유독성 폐수유입에 대해서도 안정적으로 운전이 가능한 장점이 있다. 본연구에서는 부유메디아 생물반응기(Moving-Bed BioReactor, MBBR)을 이용하여 염색폐수내 $COD_{Mn}$, 색도 및 난분해성 물질인 PVA 저감에 대한 Lab-scale test 수행하였다. 실험에 사용된 염색폐수의 수질은 평균 pH 13, $COD_{Mn}$ 900 mg/L, SS 135 mg/L, 색도 1,134 [C.U.], PVA 593 mg/L였으며, 2L의 반응기를 사용하여 회분식 실험을 수행였다. 본 실험에서는 호기성 미생물에 의한 염색폐수의 생분해가 유지되는데 필요한 최적의 용존산소 농도와 이에 필요한 공기 폭기량을 결정하기 위하여 i) DO uptake rate측정과 ii) 담체의 충진율, iii) COD/N ratio, iv) Air 유량, v) 담체내 흡착제의 종류, vi) $Ca^{2+}$ 첨가가 염색폐수의 생분해에 미치는 영향을 살펴보았다. 운전시간을 7일로 하여 COD, 색도, PVA 등을 측정한 결과 담체를 첨가한 경우가 담체를 첨가하지 않은 경우 보다 제거효율이 뛰어났다. 특히 충진율 30%(C/N 3)의 경우에서 COD, 색도, PVA의 제거율이 각각 평균 65%, 70%, 60%로 가장 높은 제거효율을 나타내었다.

  • PDF