• Title/Summary/Keyword: 평형시간

Search Result 836, Processing Time 0.028 seconds

Directory Cache Coherence Scheme using the Number-Balanced Binary Tree (수 평형 이진트리를 이용한 디렉토리 캐쉬 일관성 유지 기법)

  • Seo, Dae-Wha
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.3
    • /
    • pp.821-830
    • /
    • 1997
  • The directory-based cache coherence scheme is an attractive approach to solve the caceh coherence problem in a large-scale shared-memory multiprocessor.However, the exsting directory-based schemes have some problens such as the enormous storage overhead for a directory, the long invalidation latency, the heavy network condes-tion, and the low scalability.For resolving these problems, we propose a new directroy- based caceh coherence scheme which is suitable for building scalable, shred-memory multiprocessors.In this scheme, each directory en-try ofr a given memory block is a number-balanced binaty tree(NBBT) stucture.The NBBT has several proper-ties to effciently maintain the directory for the cache consistency such that the shape is unique, the maximum depth is [log$_2$n], and the tree has the minimum number of leaf nodes among the binarry tree with n nodes.Therefore, this scheme can reduce the storage overhead, the network traffic, and the inbalidation latency and can ensutr the high- scalability the large-scale shared-memory multiprocessors.

  • PDF

Numerical Study of Thermo-hydraulic Boundary Condition for Surface Energy Balance (지표면 열평형의 열-수리적 경계조건에 대한 수치해석)

  • Shin, Hosung;Jeoung, Jae-Hyeung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.25-31
    • /
    • 2021
  • Boundary conditions for thermal-hydraulic problems of soils play an essential role in the numerical accuracy. This study presents a boundary condition considering the thermo-hydraulic interaction between the ground and the atmosphere. Ground surface energy balance consists of solar radiation, ground radiation, wind convection, latent heat from water evaporation, and heat conduction to the ground. Equations for each heat flux are presented, and numerical analyses are performed in conjunction with the FEM program for the thermal-hydraulic phenomenon of unsaturated soils. Numerical results using the weather data at the Ulsan Meteorological Observatory are similar to the measured surface temperature. Latent heat caused by water evaporation during the daytime lowers the surface temperature of the bare soil, and a thermal equilibrium is reached at nighttime when the effect of the ground condition is significantly reduced. The temperature change of the surface ground is diminished at the deeper ground due to its thermal diffusion. Numerical analysis where the surface ground temperature is the primary concern requires considering the thermo-hydraulic interaction between the ground and the atmosphere.

On response of Surface Equilibrium Temperature for Change of Surface Characteristics : An EBM Study (지표 특성 변화에 대한 평형온도의 반응 연구 : EBM 연구)

  • Seo, Ye-Won;Chu, Jung-Eun;Ha, Kyung-Ja
    • The Korean Journal of Quaternary Research
    • /
    • v.24 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Energy Balance Model (EBM) was used to experiment the distribution of surface equilibrium temperature which responds to external forcing associated with the surface characteristics. Surface equilibrium temperature is calculated as sum of incoming solar radiation and latitudinal transport is balanced with outgoing infrared radiation. To treat incoming solar radiation, the source of the earth energy, significantly for energy balance, the experiment for surface equilibrium temperature distribution was performed considering the energy balance with the latitudinal albedo change as well as land and sea distribution. In addition, linear albedo change experiment, arctic albedo 5%, 10%, 15% change experiments and the opposite albedo change experiments between arctic and mid-latitudes were performed using incoming solar radiation as an external forcing. Moreover, with and without ice-albedo feedback experiments were performed. Increasing of arctic albedo is blocked out the incoming solar radiation so that it induces decreasing of latitudinal heat transport. It is strengthened energy transport from low latitudes by keeping arctic low energy states. Therefore the temperature change in the mid-latitudes exhibits larger response than that of arctic due to the difference of transport. The land which has lower heat capacity than sea can be reach to equilibrium temperature shortly. Also land is more sensitive to temperature change with respects to albedo. Thus it induces the thermal difference between land and sea. As a result, the equilibrium temperature exhibits differently as the difference of albedo and heat capacity which are the one of surface characteristics. Surface equilibrium temperature decreases as albedo increase and the ratio of temperature change is large as heat capacity is small. The decreasing of surface equilibrium temperature with respects to increasing of linear albedo is accelerated by ice-albedo feedback. However local change of surface equilibrium temperature decreases non-linearly.

  • PDF

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

The Behavior of Microamounts of Americium in Aqueous Solution (수용액중 급위량 Am의 거동)

  • Jae, Won-Mok
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 1986
  • The behavior of micro amount of Am in aqueous solution were investigated with centrifugation method as a function of pH. In the studies described here, equilibration times were extended to 2-3 weeks to know the aging effect in radiocolloid formation. Also, the effect of the addition of foreign materials, e. g. silica gel and Fe$^{3+}$ were examined as well as the effect of presence of concentrated electrolyte. In the results, Am appeared to be rapidly adsorbed on to impurity particles for pH < 6 and probably on the container walls by an ionic sorption process. The addition of foreign material increased the fraction of Am while the addition of concentrated electrolyte hindered the process. For pH > 7 Am behaved quite differently than for pH < 6. There appeared to be rapid sorption of some Am from solution probably on the container walls followed by partial desorption that occurred over a period of 1-2 days.s.

  • PDF

The Design of Sliding Mode Controller with Nonlinear Sliding Surfaces (비선형 스위칭 평면을 이용한 슬라이딩모드 제어기 설계)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3622-3625
    • /
    • 2009
  • This study develops a variable structure controller using the time-varying nonlinear sliding surface instead of the fixed sliding surface, which has been the robustness against parameter variations and extraneous disturbance during the reaching phase. By appling TS algorithm to the regulation of the rionlinear sliding surface, the reaching time of the system trajectory is faster than the fixed method. This proposed scheme has better performance than the conventional method in reaching time, parameter variation and extraneous disturbance. The effectiveness of the proposed control scheme is verified by simulation results.

The study of Germanium analysis by Adsorption Stripping Voltammetry (흡착벗김 전압전류법을 이용한 게르마늄 분석에 관한 연구)

  • Yun, Young Ja;Jeong, David;Namgung, Mi Ok
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.171-179
    • /
    • 1995
  • This is an analytical study of germanium by adsorption stripping squarewave voltammetry. Tannic acid was used as a ligand. The accumulation potential was -0.2V, accumulation time was carried out for 60 second under constant stirring, followed by a 20 second quiescent period, and frequency was 10Hz. A hanging mercury drop electrode was used as a working electrode and acetate buffer solution, pH=4.5, as supporting electrolyte. The proper conditions of ligand for germanium analysis was established. The effect of metal ions(lead, cupper, silicon, tin, gallium) on germanium peak was also studied.

  • PDF

Estimation of the Removal Capacity for Cadmium and Calculation of Minimum Reaction Time of BOF Slag (제강슬래그의 카드뮴 제거능 평가 및 필요반응시간 결정)

  • Lee, Gwang-Hun;Kim, Eun-Hyup;Park, Jun-Boum;Oh, Myoung-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.5-12
    • /
    • 2011
  • This study was focused on the reactivity of furnace slag against cadmium to design the vertical drain method with reactive column for improving contaminated sea shore sediment. The kinetic sorption test was performed by changing the initial concentration and pH. Using pseudo-second-order model, the reactivity of furnace slag was quantitatively analyzed. Equilibrium removal amount ($q_e$) of furnace slag increased and rate constant ($k_2$) decreased with the increase of initial cadmium concentration. With the increase of pH, the equilibrium removal amount ($q_e$) and rate constant ($k_2$) increased in the same initial concentration. Required retention time was related to the inverse of the product of the equilibrium removal amount ($q_e$) multiplied by rate constant ($k_2$). The required retention time could be used to design the length of reactive column.

Effects of Concentration and Immersion Time of Three Cryoprotective Agents on the Embryos Development of Abalone Haliotis discus hannai (결빙억제제의 종류, 농도 및 침지시간이 참전복 Haliotis discus hannai 발생배의 생존활성에 미치는 영향)

  • Chung, Jong-Kyun;Lim, Han-Kyu;Son, Maeng-Hyun;Kim, Jong-Hyun;Jeong, Min-Hwan;Chang, Young-Jin
    • Development and Reproduction
    • /
    • v.15 no.4
    • /
    • pp.301-308
    • /
    • 2011
  • The tolerance evaluation for abalone Haliotis discus hannai embryos was performed using different concentrations of cryoprotective agents (CPAs): dimethyl sulfoxide, ethylene glycol and propylene glycol added to 0.2 M sucrose, respectively. 4-cell, trochophore and veliger were exposed in each CPA with different concentration for 10, 20 and 30 minutes of immersion time. Developmental rates were increased with decreased concentration of every CPA and decreased immersion time, and differed from types of CPA. Developmental rates of veliger in all the CPAs were higher than those of 4-cell and trochophore. The developmental rates and larval activity indices in ethylene glycol were comparatively higher than those in other CPAs and the effective CPA and its concentration for the cryopreservation of the abalone embryos was suggested as 2.0 M ethylene glycol with equilibration time of 30 minutes.

Temperature Distribution and It's Contribution to Self-equilibrium Thermal Stress in Bridge (교량 단면 내 온도분포에 따른 자체평형 열응력 해석)

  • Kwak, Hyo-Gyoung;Kwon, Se-Hyung;Ha, Sang-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.531-542
    • /
    • 2011
  • The time-dependent temperature distribution across the section in bridges is determined on the basis of the three-dimensional finite element analyses and numerical time integration in this study. The material properties which change with time and thermal stress of concrete are taken into account to effectively trace the early-age structural responses. Since the temperature distribution is nonlinear and depends upon many material constants such as the thermal conductivity, specific heat, hydration heat of concrete, heat transfer coefficients and solar radiation, three representative influencing factors of the construction season, wind velocity and bridge pavement are considered at the parametric studies. The validity of the introduced numerical model is established by comparing the analytical predictions with results from previous analytical studies. On the basis of parametric studies for four different bridge sections, it is found that the creep deformation in concrete bridges must be considered to reach more reasonable design results and the temperature distribution proposed in the Korean bridge design specification need to be improved.