• Title/Summary/Keyword: 평행평판

Search Result 158, Processing Time 0.02 seconds

A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide (평행판 도파관을 이용한 유전율 측정 방법)

  • Cho, Gyo-Yeong;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.199-203
    • /
    • 2012
  • This paper introduces a simple new procedure approach to determine the permittivity of dielectric slabs. The method uses a parallel plate waveguide which supports a TEM mode. The presence of the dielectric slab placed at the bottom of the waveguide makes the speed of the TEM wave slower. The relationship between the change of the speed and the permittivity of the dielectric slab allows the determination of the permittivity. The relationship is analyzed electromagnetically, and the results of measurements are in good agreement with the analysis.

용량 결합형 플라즈마의 유전체기판의 잔류전위 양상 관찰

  • Yun, Yong-Su;Wi, Seong-Seok;Kim, Dong-Hyeon;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.130-130
    • /
    • 2015
  • 플라즈마를 이용한 cleaning, etching, sputtering 공정에서 발생하는 마이크로아크방전이나 turn-off후의 잔류정전기는 공정대상물의 절연파괴나 전자소자에 전기적 손상을 유발함으로서 공정의 불량률을 증가시키는 중요한 요인이 된다. 본 연구에서는 잔류정전기를 관찰하기위하여 실린더형 챔버구조의 평행평판 전극구조를 지닌 용량결합형 플라즈마에서 powered electrode에 부착된 유전체 기판 표면의 잔류 정전기의 변화 양상을 planar type probe로 측정해보았다. 300mtorr 압력에서 아르곤가스로 발생시킨 플라즈마가 존재할 때 낮은 음전위 평균값을 가지던 기판표면 전위가 전력인가가 중지되었을때 20V 가량의 양전위를 가질 수 있음을 측정 하였고, 이것을 COMSOL MULTIPHYSICS TOOL을 활용한 시뮬레이션과 비교하였다. 이 현상이 파워인가 전극이 플라즈마 영역에 노출되느냐에 따라 발생할 수 있음을 알게 되었고, 그 크기와 지속시간은 입력전력 및 블로킹 커패시터와 유전체 기판의 정전용량에 의존함을 확인 하였다.

  • PDF

An Analysis of Fully Developed Turbulent Heat Transfer and Flow in an Annulus with the Square-Ribbed Roughness on Both Walls (양측벽면에 사각돌출형 거칠기가 있는 이중관내의 난류유동과 열전달 해석)

  • 안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.33-41
    • /
    • 1993
  • 양벽면 모두 사각돌출형조도요소가 설치된 동심 이중관내에서 생기는 비대칭 난류유동과 열전달 특성을, 열전달과 마찰계수에 미치는 조도의 합성효과를 조사하기 위해, 연구하였다. 이론해석에서는 한쪽면에 거칠기가 있는 평행평판의 유동에 대한 수정 플란틀 혼합길이(mixing length)이론의 난류 모델을 속도분포와 마찰계수를 구하는데 사용하였다. 최대속도지점에서 안쪽과 바깥쪽의 두 속도형상들은 힘의 평형에 의해 일치시켰다. 그리고 나서, 온도 분포와 열전달 계수를 계산하였다. 속도형성과 마찰계수들의 해석결과는 실험과 매우 잘 일치하였다. 마찰계수와 Nusselt number에 미치는 조도비, 조도에 대한 피치비, 그리고 반경비등과 같은 여러 변수들의 효과들을 조사하였다. 본 연구는 일정의 조도 요소들이 전체적 효율 측면에서 볼때 유리하게 열전달을 향상시킨다는 것을 증명하였다.

  • PDF

Fully Developed Turbulent Flow and Heat Transfer in Concentric Annuli with Surface Roughness (표면거칠기가 있는 이중관내의 완전히 발달된 난류유동과 열전달)

  • 안수환;김형진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.45-54
    • /
    • 1993
  • 동심 이중관내에서 사각돌출형 조도요소에 의한 비대칭 난류유동과 열 전달특성을, 열전달과 마찰계수에 미치는 조도의 합성효과를 조사하기 위해, 연구하였다. 이론해석에서는 한쪽면에 거칠기가 있는 평행평판의 유동에 대한 수정 플란틀 혼합길이(mixing length)이론의 난류모델을 속도분포와 마찰계수를 구하는데 사용하였다. 최대속도지점에서 안쪽과 바깥쪽의 두 속도형상들은 힘의 평형에 의해 매치(match) 시켰다. 그리고나서, 온도 분포와 열전달 계수를 계산하였다. 속도형상과 마찰계수들의 해석결과는 실험과 매우 잘 일치하였다. 마찰계수와 Nusselt number에 미치는 조도비, 조도에 대한 피치비, 그리고 반경비등과 같은 여러 변수들의 효과들을 조사하였다. 본 연구는 일정 임의의 조도 요소들이 전체적 효율 측면에서 볼 때 유리하게 열전달을 향상시킨다는 것을 증명하였다.

  • PDF

Monte carlo analysis of radiation heat transfer through an absorbing-emitting gray gas between parallel plates (흡수-방사하는 회가스를 지닌 평행평판 사이의 복사열전달의 Monte Carlo 방법에 의한 해석)

  • ;;Lee, Taik Sik
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.3
    • /
    • pp.244-250
    • /
    • 1981
  • The rediant heat tranfer and temperature distribution between infinite parallel gray plates at different temperatures separated by an absorbing and emitting gray gas with or without a sinusoidal heat source in the gas are analyzed by Monte Carlo method. The Monte Carlo result were compared with the numerical solution by Usiskin and Sparrow and the exact solution by Hottel in the case of similar problem limited black walls and gas optical thickness is less than two. For gray walls and large optical thichness the results were compared with modified diffusion approximate solution by Deissler.

EDUCATION OF ELECTROMAGNETIC PENETRATION THROUGH NARROW SLOTS IN CONDUCTING SCREEN BY PARALLEL PLATE LOADING (평행평판 장하에 의한 슬릿 침투 전자파의 저감 특성)

  • Park, Eun-Jung;Ju, Chang-Hyun;Kim, Ki-Chai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.66-68
    • /
    • 2005
  • This paper presents the reduction characteristics of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the parallel plate connected on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. An integral equation for the aperture electric field on narrow slots is derived and solved by applying Galerkin's method of moments. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel plate on the slot aperture.

  • PDF

Large eddy simulation of turbulent premixed flame with dynamic sub-grid scale G-equation model in turbulent channel flow (Dynamic Sub-grid Scale G-방정식 모델에 의한 평행평판간 난류의 예 혼합 연소에 관한 대 와동 모사)

  • Ko Sang-Cheol;Park Nam-Seob
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.849-854
    • /
    • 2005
  • The laminar flame concept in turbulent reacting flow is considered applicable to many practical combustion systems For turbulent premixed combustion under widely used flamelet concept, the flame surface is described as an infinitely thin propagating surface that such a Propagating front can be represented as a level contour of a continuous function G. In this study, for the Purpose of validating the LES of G-equation combustion model. LES of turbulent Premixed combustion with dynamic SGS model of G-equation in turbulent channel flow are carried out A constant density assumption is used. The Predicted flame propagating speed is goof agreement with the DNS result of G. Bruneaux et al.

Analysis of laminar forced convection for optimal design of parallel plates with protrusions (돌출부를 갖는 평행평판의 최적 설계를 위한 층류강제대류 해석)

  • 이관수;박철균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.129-136
    • /
    • 1998
  • Pressure drop and heat transfer characteristics of a periodically fully developed flow in the flat channel with protrusions are investigated. The effects of shape and location of protrusion on the pressure drop and heat transfer are numerically analyzed in the present study. Taguchi method is used to optimize these parameters. It is found that the ratio of the height of protrusion to channel height shows larger influence on the pressure drop and heat transfer than the ratio of the length of protrusion to module length. As the height of protrusion increases, pressure drop and heat transfer increase, but if the height of protrusion exceeds 2/3 of the channel height, there is a substantial pressure drop. The results also show that the optimal length and height of protrusion are half of the module length and half of the channel height, respectively.

  • PDF

Improved closed-form Green's function for a horizontal magnetic dipole in a parallel-plate waveguide (평행평판 도파관내 수평자기쌍극자에 대한 개선된 단순함수형태의 그린함수)

  • 이영순;권호상;조영기
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.5
    • /
    • pp.24-32
    • /
    • 1998
  • Spatial green's functions for a horizontal magnetic dipole in a parallel-plate waveguide are expressed in an improved closed-form with two-level approximation of the spectral green's functions. The results evaluated by the present closed-from green's function with two-level approximation are compard with those obtained the previous closed-form green's function with one-level approximation. The present results are observed to be more acurate than the previous results over wide frequency range as well as whole spatial range. The combination of the present closed-form green's functions and the moment mehtod may help in analyzing the problem of EMP coupling through an aperture into a parallel-plat waveguide and the microstrip slot antenna with a reflector.

  • PDF

Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by using PIV Technique (평행평판 전극사이에서 PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구)

  • Chang Tae-Hyun;Chang Ki-Won
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.103-106
    • /
    • 2003
  • An experimental investigation was peformed to study the characteristics of ER(Electro-Rheological) fluid water flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the claster of ERF are clearly strong along the test tube and the flow rate decreased.

  • PDF