A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging (진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성)

  • Park, Ji-Koon;Heo, Ye-Ji;Park, Jeong-Eun;Park, Sang-Jin;Kim, Hyun-Hee;No, Ci-Chul;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.35-38
    • /
    • 2009
  • Flat-panel x-ray detectors using a phosphor and photoconductor material have been used for application in various medical modalities. In this study, the monte carlo simulation, optical and x-ray response characteristics were investigated in the conversion structure obtained by a columnar CsI:Na scintillation layer with a photosensitive amorphous selenium layer. Firstly, from the measurement of luminescent spectrum of CsI:Na and absorption spectrum of a-Se layer, the signal conversion characteristics are analysed. And also, the x-ray sensitivity is measured and compared with conventional a-Se($500{\mu}m$) as a function of electrical field. From the experimental result, the x-ray sensitivities of the CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) detector and the a-Se($500{\mu}m$) detector were $7.31nC/mR-cm^{2}$ and $3.95nC/mR-cm^{2}$at an electric field of $10V/{\mu}m$, respectively.

  • PDF

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

An internal partial discharge measurement method excepted an external corona noise (외부 코로나 노이즈를 제거한 내부 부분방전 측정기법)

  • 권동진;진상범;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2001
  • The largest problem in applying the elecbical partial discharge measurement method the transformer that has been operated until now is the removal of external corona noise In this thesis, a methcd was studied. to rneasme only fue partial discharge sIgnal due to the defoct in transfonrer except the external corona noise. To find out the types of partial discharge and corona noise within a transfomr, a partial discharge was made in use of a needle-plane electrodes within a model transfonner and, at the same time, an external corona noise was generated in use of a rod-sphere electrcdes in the air around the transformer. Both of a partial clischarge signal caused from an intemat defect within a transformer and an external noise were found at the rogowski coil which was located at transformer earth wire. When the external corona noise, which was separately measured in use of an antenna sensor out of transfonner, was removed from the signal measured on rogowski coil, the signal caused by partial discharge within a transformer would effectively be acquired.quired.

  • PDF

Optimization of Parallel-Hole Collimator for Small Gamma Camera Based on Pixellated Crystal Array (배열형 섬광결정을 이용한 소형 감마카메라의 평행구멍형 조준기 최적화 연구)

  • Chung, Yong-Hyun;Beak, Cheol-Ha;Lee, Seung-Jae;Park, Jin-Hyung
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.291-297
    • /
    • 2008
  • The purpose of this study is to optimize a parallel-hole collimator for small gamma camera having the pixellated crystal array and evaluate the effect of crystal-collimator misalignment on the image quality using a simulation tool GATE (Geant4 Application for Tomographic Emission). The spatial resolution and sensitivity were measured for the various size of hexagonal-hole and matched square-hole collimators with a Tc-99m point source and the uniformity of flood image was estimated as a function of the angle between crystal array and collimator by misalignment. The results showed that the spatial resolution and sensitivity were greatly improved by using the matched collimator and the uniformity was reduced by crystal-collimator misalignment.

  • PDF

Design of Color Matching Filters and Error Analysis in Colorimetric Measurement of LCD Flat Panel Display Using the Filters (등색함수 필터의 설계와 이를 이용한 LCD 평판 디스플레이의 색채 측정에 대한 오차 분석)

  • Jeon, Ji-Ho;Jo, Jae-Heung;Park, Seung-Nam;Park, Chul-Woung;Lee, Dong-Hoon;Jung, Ki-Lyong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Filter colorimeters have a set of spectral bands for which spectral responsivity is the same as the color matching function defined by CIE (Commission Internationale de I'Eclairage). We have designed a set of color matching function filters denoted by $\bar{x}-filter,\;\bar{y}-filter,\;and\;\bar{z}-filter$. Because the $\bar{x}-function$ has two transmission bands, two $\bar{x}-filters$ are designed to cover the $\bar{x}-function$. To design the filters, we developed a nonlinear least square fit program which determines the thickness of the color glasses by minimizing its spectral mismatch value ($f{_1}'$) to below 3 %. The design has been validated by fabrication of the $\bar{y}-bar$ filter, of which $f{_1}'$ was measured to be 2.8 %. Considering a LCD flat panel display as a device under test, we have calculated the systematic error of the colorimetric measurement using the designed filters.

The Characteristics of Frequency Spectrum of the radiated Electromagnetic Waves with AC Discharge Progress in Air (대기중 교류 방전진전에 따른 방사전자파의 주파수 스펙트럼 특성)

  • 박광서;최병주;김기채;김이국;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.81-87
    • /
    • 2003
  • This paper simulated discharge progress and partial discharge using needle-plan electrode system in air, in this time with discharge progress, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study, a method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with AC discharge progress in air, Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

Investigation of Geometrical Properties on Deposition Rate in Cesium Iodine Film (증착속도에 따른 CSI layer의 기하학적 특성 연구)

  • Lee, Kyu-Hong;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Yul;Cho, Sung-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.415-417
    • /
    • 2003
  • CsI 형광체는 X선에 대한 분해능 및 변환효율이 우수한 물질이다. 최근 대면적 평판형 X선 영상검출기의 변환층으로 이용하기 위해 CsI 형광체의 대면적 제조에 대한 연구가 활발히 진행되고 있다. 본 논문은 진공 열증착법을 이용하여 증착속도(3, 3.8, $4.5\;{\mu}m/min$)에 따라 $20\;{\mu}m$ 두께의 CsI 필름을 제조하였고, XRD 및 SEM 분석을 통해 CsI 필름의 기하학적 구조를 조사하였다. 증착된 CsI 필름은 증착속도에 관계없이 복잡한 다결정 구조를 가지며, $3\;{\mu}m/min$의 증착속도에서 약 $1\;{\mu}m$ 크기로 needle-like 한 columnar structure를 가졌다. As results, about 3um/min evaporation rate formed as good geometry characteristics CsI layer.

  • PDF

Soaking method & Particle In Binder method를 적용한 Photoconductor materials의 제작방식에 따른 X-ray Detector film 제작 및 전기적 특성평가

  • Lee, Yeong-Gyu;Yun, Min-Seok;Kim, Min-U;Kim, Yun-Seok;Jeong, Suk-Hui;Jeon, Seung-Pyo;Park, Geun-U;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.72-72
    • /
    • 2009
  • 본 연구에서는 Photoconductor materials 기반의 평판형 X-ray Detector film 제작에 관한 연구를 수행하였다. 기존의 광도전성 물질로 사용되어 오던 비정질 셀레늄(Amorphous seleinum; a-Se) 기반의 디지털 방사선 검출기 보다 높은 신호 및 동작 특성을 가지는 Mercury Iodide(HgI2)와 열적, 전기적 특성이 안정적이며, 소자의 동작특성이 우수한 Lead Oxide(PbO) 기반의 X-ray Detector film의 개발에 있어서 각각 HgI2 및 PbO 두 물질 층을 적정비율에 맞추어 제작함으로써 최적의 X-ray Detector를 구현하고자 하였다. 이는 빠른 영상획득을 통해 기존의 방식이 가지는 문제점을 해결하고 의료기기 디지털화를 구현할 수 있는 차세대 시스템을 개발하고자 하는 것이다. 본 연구에서는 기존의 진공증착법의 두꺼운 대면적 필름의 제조가 어려운 문제점을 해결하고자 Particle In Binder method(PIB) 방법을 이용하여 $3"{\times}3"$사이즈의 두께 $200{\mu}m$의 다결정의 Photoconductor 필름을 제조하여 전기적 특성을 평가하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 기준 실험으로 진행한 DG 2.1 바인더를 사용한 single-HgI2 층에서 보다 높은 sensitivity 값을 보였지만 높은 dark current로 인해 SNR이 떨어지는 결과를 볼 수 있었다. 본 연구에서 제시하는 두 Photoconductor material의 Soaking method를 이용한 실험에서는 single-HgI2에 해당하는 높은 sensitivity 및 저감된 dark current로 인해 높은 SNR 값을 획득하였다. 하지만 습도와 같은 주변 환경에 의한 재현성 문제로 인한 신호값의 불안정성에 대한 문제점도 남아 있으므로, 차후 최적화된 material 제작 공정을 위한 연구가 꾸준히 진행 되어져야 할 것이다.

  • PDF

Ghosting Artifacts in Digital Radiography (디지털 방사선영상에서 고스팅 아티팩트)

  • Jung, Wonhee;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.377-382
    • /
    • 2014
  • Because of using computer system in the field of medical radiology, many artifacts which can not be seen in film/screen system are being created, especially ghosting artifacts. This artifacts could be yielded by taking advantage of a flat panel Thin-Film Transistor array detector. Ghosting artifacts can be rarely seen in clinical practice when an image that has a high-contrast object within a region of high exposure is quickly followed by another image that puts the high-contrast ghosting image in an area of lower radiation exposure. In this experiment, the ghosting artifacts were minimized for approximately 3 minutes with the unaided eye and almost disappeared for 6 minutes quantitatively between exposures. Moreover, the artifacts were influenced by more tube voltage than current and those depended not upon the number of readout cycles, but upon time.