• Title/Summary/Keyword: 평면 위치결정 정도

Search Result 34, Processing Time 0.031 seconds

A Study on Measurement of Linear Cycle Plane Positioning Accuracy of NC Lathe (NC선반의 직선 사이클 평면 위치결정 정도 측정에 관한 연구)

  • 김영석;송인석;정정표;한지희;윤원주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-58
    • /
    • 2003
  • It is very important to measure linear cycle plane positioning accuracy of NC lathe as it effects all other parts of machines machined by them in industries. If the plane positioning accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear cycle plane positioning displacement of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales. And each sets of error data obtained from the test is descriptions to plots and the results of linear cycle plane positioning errors are expressed as nutriments by computer treatment.

The Organization of Measuring Systems of Linear Cycle Plane Positioning Accuracy on NC Lathes (NC 선반에서 직선 사이클 평면 위치결정 정도 측정 시스템의 구성)

  • 김영석;김재열;송인석;곽이구;정정표;한지희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.387-392
    • /
    • 2002
  • It is very important to measure linear cycle plane positioning accuracy of NC lathes as they affect those of all other machines machined by them in industries. For example, if the linear cycle plane positioning accuracy of each axes directions is bad, the accuracy of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear displacements of ATC(Automatic tool changer) of NC lathes using linear scale and time pulses comming out from computer in order to get data at constant time intervals from the sensors. And each sets of error data gotten from the test is expressed to plots by computer treatment and the results of linear cycle plane positioning error motion estimated to numerics by statistical treatments.

  • PDF

Crystal Structure of a Methanol Sorption Complex of Dehydrated Partially Cobalt(Ⅱ)-Exchanged Zeolite A (부분적으로 Co(Ⅱ) 이온으로 치환한 제올라이트 A를 탈수한 후 메탄올을 흡착한 결정구조)

  • Jang, Se Bok;Han, Yeong Uk;Kim, Yang
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.5
    • /
    • pp.339-344
    • /
    • 1994
  • The crystal structure of a methanol sorption complex of dehydrated partially Co(II)-exchanged zeolite A, $Co_4Na_4-A{\cdot}6.5CH_3OH$ (a = 12.169(1) $\AA)$, has been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm$\bar3$m at $21(1)^{\circ}C. $Co_4Na_4$-A was dehydrated at $360^{\circ}C\;and\;2{\times}10^{-6}$ torr for 2 days, followed by exposure to about 104 torr of methanol vapor at $22(1)^{\circ}C$ for 1 hr. The structure was refined to final error indices, $R_1$ = 0.061 and $R_2$ = 0.060 with 147 reflections, for which I > $3\sigma(I).$ In this structure, four $Co^{2+}$ ions and 1.5 $Na^+$ ions per unit cell lie at 6-ring positions: the $Na^+$ ions are recessed 0.44 $\AA$ into the sodalite unit and the Co(II) ions extend ca. 0.55 $\AA$ into the large cavity. 2.5 $Na^+$ ions lie in an 8-oxygen ring plane. The 6.5 methanol molecules are sorbed per unit cell. The 6.5 methanol oxygens, all in the large cavity, associate with the 4 $Co^{2+}$ ions and 2.5 $Na^+$ ions.

  • PDF

Analysis on the motion characteristics of surface XY aerostatic stage (평면 XY 공기정압 스테이지의 운동특성 분석)

  • 황주호;박천홍;이찬홍;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.359-362
    • /
    • 2003
  • The aerostatic stage. which is used in semiconductor process, is demanded higher velocity and more precise accuracy for higher productivity and integrated performance. So, in the case of XY stage, H type structure, which is designed two co-linear axis of guide-way, driving force in one surface, has advantage of velocity and accuracy compared to conventional tacked type XY stage. To analyze characteristics of H type aerostatic stage, H type aerostatic surface XY stage is made, which is driven by linear motor and detected position with precise optical linear scale. And, analyze characteristics of motion error, effect of angular motion on positioning accuracy error and effect of simultaneous control on variation of velocity.

  • PDF

Crystal Structure of an Acetylene Sorption Complex of Vacuum Dehydrated Fully Cadmiumfiil-Exchanged Zeolite A (완전히 카드뮴 이온으로 교환된 제올라이트 A를 진공 탈수한 후 아세틸렌 기체로 흡착한 결정구조)

  • Koh, Kwang-Nak;Han, Young-Wook;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.2 no.1
    • /
    • pp.17-22
    • /
    • 1991
  • The crystal structure of an acetylene sorption complex of vacuum dehydrated fully Cda+ _exchanged zeolite A has been determined from three-dimensional X-ray diffraction data gathered by counter method. The structure was solved and refined in the cubic space group Pm3m at 294(1) K, a=12.202(3) A and Z=1. We crystal was prepared by dehydration at 723 K and 2.67×104 Pa for 2 days, followed by exposure to 1.60×104 Pa of acetylene gas at 298(1) K. All six Cd2+ions per unit cell are associated with 6-oxgen rings of the aluminosilicate framework. They are distributed over two distinguished threefold axes of unit cell; two of these Cd2+ ions are recessed 0.694 into the sodalite unit from (111) plane of three 0(3)'s and each approaches three framework oxides; the other four Cd2+ ions extend approximately 0.586A into the large cavity. The four Cd2+ ions are in a near tetrahedral environment, 2.220(9)A from·three framework oxide ions and 2.74(7) A from each carbon atom of an acetylene molecule(which is here counted as a monodentate ligand). Full matrix least squares refinement converged to the final error indices R1=0.093 and R2=0.105 using the 292 independent reflections for which I>3σ(I).

  • PDF

Coordinates Determination of tow Level Control Point by Aerial Triangulation (사진기준점측량을 이용한 저등급 기준점의 좌표결정)

  • 최재화;이석배;최윤수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.6 no.2
    • /
    • pp.34-41
    • /
    • 1988
  • Nowadays the considerable improvements, not only in photogrammetric equipment but also in adjustment methods have led to a high accuracy of Aerial Triangulation and reach the step to obtain A.T. technique that uses Global Position System without ground control survery. The enterance of analytical plotter have made considerable development both in accuracy and in efficiency and improved working environment of A.T. by the combination of On-Line Analytical Plotting System. In this paper, in A.T., with using of analytical polotter, aims to improve the acccuracy in coordinates determination of low level control point. The result shows that in case of A.T. with analytical plotter AVIOLYT BC2, the accuracy of control points improves to 7% in planimetry and to 40% in height compared to A.T. with precision plotter Autograph A-8.

  • PDF

A study on the postoperative stability of occlusal plane in Class III orthognathic surgery patients (제 III급 부정교합자의 양악수술후 교합평면의 안정성에 관한 연구)

  • Lee, Yoon-Jeong;Sohn, Byung-Wha
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.643-655
    • /
    • 2000
  • In Patients with severe skeletal discrepancy, surgical orthodontic treatment must be accompanied, and recently two jaw surgery has become a common procedure, resulting in improved esthetics and function. Choosing the position of the occlusal plane in this two jaw surgery is an important factor in postoperative stability Therefore this must be taken into consideration during the diagnosis and treatment plan. In this study, among patients with skeletal Class III occlusion, 25 patients(8 male, 17 female, average age $23.2{\pm}3.17$) who have undergone two jaw surgery, setting the ideal occlusal plane according to Delaire's architectural and structural cranial analysis. In comparing preoperative($T_1$). postoperative($T_2$, average of 15.4 days), and long-term postoperative($T_3$, average of 32.6 months) lateral cephalometric radiography, the following conclusions have been made. 1. There were no significant changes of the occlusal plane angle after the two jaw surgery, and there were no significant differences between the surgical technique(SSRO and IVRO). 2. The postoperative changes of the occlusal Plane had no relationship with the amount of jaw movement, amount of posterior impaction, nor the time relapse after surgery. 3. After two jaw surgery, in the SSRO group there was significant forward movement of the mandible, and in the IVRO group the lower incisors extruded as the mandible moved backward and downward which makes the genial angle and the mandibular plane angle significantly increased

  • PDF

Effect of Floor Plan Characteristics on Housing Price - Focused on the Apartment in 3 Gangnam Districts since 2005 - (공동주택 평면특성의 가격영향에 관한 연구 - 강남3구의 2005년 이후 분양주택을 중심으로 -)

  • Bae, Sangyoung;Lee, Jaewon;Lee, Sangyoub
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.4
    • /
    • pp.102-110
    • /
    • 2018
  • The study analyzed the effects of the floor plan characteristics on the apartment price under the national housing size in 3 Gangnam districts for decades, the primary apartment markets in Korea. The analysis showed that the storage spaces such as kitchen, warehouses and dressage rooms have a positive effect on the price. Especially, the highly opened space with three-side open plan and the one with the unified type of livingroom, diningroom and kitchen have shown the strong effect on the price. For the kitchen spaces, the I-shaped kitchen tends to be more expensive while a centered living room has a positive effect on the price. These findings have an academic significance as the direct effects of plan characteristics on price has been examined unlike prior research focused on the analysis of trend, basic statistics, and satisfaction level. It is noteworthy that these research finding has identified the productive implication for the future floor plan design and pricing and also be implemented in the purchasing decision making by buyers in the housing market.

ROENTGENOCEPHALOMETRIC STUDY ON FACIAL HEIGHT AND OCCLUSAL PLANE INCLINATION IN CLASS II MALOCCLUSION GROUP (성인 II 급 환자의 안면 수직고경및 교합평면의 특징에 관한 두부방사선학적 연구)

  • Nahm, Dong-Seok;Jeong, Mi-Hyang
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.255-268
    • /
    • 1998
  • This study was investigated to assess the difference of facial height and occlusal plane inclination between normal occlusion group and class II malocclusion group. The subjects consisted of 50 normal occlusion (male 25, female 25) and 50 class II(male 25, female 25) malocclusion patients. All subjects are adult. lateral cephalogram was taken with standard method traced, and digitized for each subjects. The computerized statiscal analysis was carried out with SPSS program. The results were as follows 1. In class II malocclusion group, variables significant different from normal occlusion group were as follows ; SN-FOP, FH-BOP, MP-BOP, AB-BOP, AB-FOP, Facial plane-BOP, FP-FOP 2. In class II malocclusion group, the posterior facial height -especially posterior lower facial height-was significantly smaller than normal occlusion group.(P<0.05) 3. In class II malocclusion group, the angles between occlusal plane and upper and lower incisor, the angle between upper molar and bisected occlusal plane were significantly larger than those of normal occlusion group. (P<0.05) 4. L1 to Mandibular plane (mm) was a unique factor of occlusal plane position that showed significant difference in class II malocclusion group. 5. The correlation between overbite and occlusal plane inclination existed in class II malocclusion group, but the correlation didn't exist in normal occlusion group.

  • PDF

Crystal Structures of Vacuum Dehydrated Fully $Cd^{2+}$-Exchanged Zeolite A and of Its iodine Sorption Complex (카드뮴 이온으로 완전히 치환한 제올라이트 A를 진공 탈수한 구조와 이것에 요오드를 흡착한 결정구조)

  • Jang, Se-Bok;Han, Young-Wook;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.4 no.2
    • /
    • pp.54-62
    • /
    • 1993
  • The crystal shnture of dehydrated fully Cd2+-exchanged zeolite A evacuated at 2 × 10-6 Torr and 650℃ (a:12.189(2) A) and of its iodine sorption corrplex (a:12.168(2)A) have been netsmlmn by single uystal x-ray diffraction techliques in the cubic space group hkTn at 21(1)℃. The strutures were refined to final error indices, Ri:0.057 and R2 =0.063 with 186 reflections and Rl:0.082 and R2:0.085 with 181 reflections, respectively, for which 1>3σ(In both structure, six lie at two distinguished threefold axes of unit cell ten the crystal structure of an iodine sorption complex of Cd6-A four Cd2+ ions are recessed 0.69(1) A into the large cavity to complex each with from the (111) plane of 0(3), whereas two Cd2+ ions recessed 0.68(1) A into the sodalite unit Awximately 4.0 l3ions per nit cell are sorbed. Each bridge between a Cd2+ ion and 8-ring oxygens ((I-I-I)= 117(1) ˚ and 0(1)-I(1)-I(2)=172(1)). The near linear I-I-0 angle and its interatomic distance (I-0=3.57(3) A) are indicative of a weak charge transfer interacticn between the frarrework oxygen and iodine. The existence of In3 inside the large cavity indicates that the If ions and H ions may be produced by reaction of In vapor with water molecules which maybe associated with Cd2+ ions in partially dehydrated Cd6-A In3- ions may be produced by the combination of I- and I2.

  • PDF