• Title/Summary/Keyword: 평균체류시간

Search Result 172, Processing Time 0.033 seconds

An Analysis of the Behavior and the Preference of Roof Spaces Depending on Building Types - A Focus on the Case of Seoul, Korea - (건물용도별 옥상공간의 이용행태 및 선호도 분석 - 서울특별시의 사례를 중심으로 -)

  • Kim, Eun-Jin;Jung, Tae-Yeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.10-20
    • /
    • 2014
  • Today, most roof spaces are being designed as places for resting. The use of the roof spaces needs to be raised otherwise, budgeting or costs involved can be wasteful. A well-made plan is needed to increase the use of the roof spaces. The behavior of and preference for roof spaces could differ depending on building usage because the users of these roof spaces can be different. Therefore, this study selected 4 building types depending on usage: public buildings, educational and research buildings, medical buildings, and commercial buildings. Two buildings that created roof spaces per building type were selected. A survey was undertaken of the user experience of roof spaces on the buildings. The behavior and preference of roof spaces depending on building types were analyzed and the results are as follows. The behavior of using roof spaces regarding purpose, motivation, frequency, and average length of stay were different depending on the building types. In terms of purpose, over all four building types, taking a rest was the primary reason for using roof spaces. However, talking and smoking in public buildings, smoking, taking a walk or stretching, and viewing the exterior landscape in educational and research buildings, taking a walk or stretching and talking in medical buildings, taking care of children and talking in commercial buildings were also important reasons for using roof spaces. The preference of roof space components such as plants, paving materials, and facilities were different depending on the building types. In terms of plants, the users of public buildings preferred herbaceous plants and vegetables/aquatic plants more than the users of other building types. The users of medical buildings preferred vegetables/aquatic plants, and the users of commercial buildings preferred arbores, herbaceous plants, and vegetables/aquatic plants more than the users of other building types. This study provides empirical data for the behavior and the preference of roof spaces depending on building types. These findings could provide new insights into how to increase the use of roof spaces.

Role of Intra-aortic Balloon Pump in High Risk Patients undergoing Off-Pump Coronary artery bypass graft (심폐바이패스 없이 시행하는 관상동맥 우회술시 고위험군 환자에서 대동맥내 풍선 펌프의 유용성)

  • Cho, Suk-Ki;Jang, Woo-Ik;Lim, Cheong;Lee, Cheul;Lee, Jae-Ik;Kim, Yong-Lak;Ham, Byung-Moon;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.895-900
    • /
    • 2001
  • Background : This study aimed to evaluate the usefulness of preoperative placement of intraaortic balloon pump(IABP) in reducing operative risk and facilitating posterior vessel OPCAB in high risk patients with left main disease( 75% stenosis), intractable resting angina, postinfarction angina, or left ventricular dysfunction(ejection fraction 35%). Material and Method : One hundred eighty- nine consecutive patients who underwent multi-vessel OPCAB including posterior vessel revascularization were studied. The patients were divided into group I(n=74) that received preoperative or intraoperative IABP and group II(n=115) that did not receive IABP. In group I, there were 39 patients with left main disease, 40 patients with intractable resting angina, 14 patients with left ventricular dysfunction and 7 patients with postinfarction angina. Ten patients received intraoperative IABP support due to hemodynamic instability during OPCAB. Result : There was one operative mortality in group I and two mortalities in group II. The average number of distal anastomoses was not different between group I and group II(3.5$\pm$0.9 vs 3.4$\pm$0.9, p=ns). There were no significant differences in the number of posterior vessel anastomosis per patient between the two groups. There were no differences in ventilator support time, length of hospital stay, and morbidity between the two groups. There was one case of IABP-related complication in group I. Conclusion : IABP facilitates posterior vessel OPCAB in high risk patients, with comparable surgical results to low risk patients

  • PDF

Evaluation of Design and Operation Parameters for a Spherical Sulfur Denitrification Reactor Treating High Strength Municipal Wastewater (고농도 도시하수 처리를 위한 입상황 탈질 반응조의 설계 및 운영인자 평가)

  • Kim, Yong-Hak;Chae, Kyu-Jung;Yim, Seong-Keun;Lee, Young-Man;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1087-1093
    • /
    • 2010
  • Autotrophic denitrification is known as an effective and economical alternative for heterotrophic denitrification using external carbon sources such as methanol. In this study, we evaluated design and operation parameters for a sulfur denitrification reactor (SDR) treating high strength nitrogen wastewater. The SDR was filled with spherical sulfur media in connected to a pilot-scale nutrient removal process (daily flow rate, $Q=18\;m^3/d$) using moving spongy media. Total nitrogen (TN) concentration of the final effluent was below the 7.0 mg TN/L because nitrate was additionally removed through autotrophic denitrificationin without adding alkalinity (initial alkalinity was $169.4{\pm}20.8\;mg$ $CaCO_3$/L). During the test period, 60~80% of nitrogen in the influent was removed even in low temperature (below $15^{\circ}C$). The alkalinity consumption for nitrate removal in SDR was $4.09{\pm}1.29$ g $CaCO_3/g$ ${NO_3}^-$-N, and the residual alkalinity of influent of SDR was higher than that of theoretical requirements for full conversion of nitrate. The consumption of sulfur was 943.8 g S/d and it was 2.4 times higher than theoretical value (400.1 g S/d) due to abrasion and loss of sulfur media in backwash, etc.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Hydrochemistry and Noble Gas Origin of Various Hot Spring Waters from the Eastern area in South Korea (동해안지역 온천유형별 수리화학적 특성 및 영족기체 기원)

  • Jeong, Chan-Ho;Nagao, Keisuke;Kim, Kyu-Han;Choi, Hun-Kong;Sumino, Hirochika;Park, Ji-Sun;Park, Chung-Hwa;Lee, Jong-Ig;Hur, Soon-Do
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • The purpose of this study is to characterize the hydrogeochemical characteristics of hot spring waters and to interpret the source of noble gases and the geochemical environment of the hot spring waters distributed along the eastern area of the Korean peninsula. For this purpose, We carried out the chemical, stable isotopic and noble gas isotopic analyses for eleven hot spring water and fourteen hot spring gas samples collected from six hot spring sites. The hot spring waters except the Osaek hot spring water show the pH range of 7.0 to 9.1. However, the Osaek $CO_2$-rich hot spring water shows a weak acid of pH 5.7. The temperature of hot spring waters in the study area ranges from $25.7^{\circ}C$ to $68.3^{\circ}C$. Electrical conductivity of hot spring waters varies widely from 202 to $7,130{\mu}S/cm$. High electrical conductivity (av., $3,890{\mu}S/sm$) by high Na and Cl contents of the Haeundae and the Dongrae hot spring waters indicates that the hot spring waters were mixed with seawater in the subsurface thermal system. The type of hot springs in the viewpoint of dissolved components can be grouped into three types: (1) alkaline Na-$HCO_3$ type including sulfur gas of the Osaek, Baekam, Dukgu and Chuksan hot springs, and (2) saline Na-Cl type of the Haeundae and Dongrae hot springs, and (3) weak acid $CO_2$-rich Na-$HCO_3$ type of Osaek hot spring. Tritium ratios of the Haeundae and the Dongrae hot springs indicate different residence time in their aquifers of older water of $0.0{\sim}0.3$ TU and younger water of $5.9{\sim}8.8$ TU. The ${\delta}^{18}O$ and ${\delta}D$ values of hot spring waters indicate that they originate from the meteoric water, and that the values also reflect a latitude effect according to their locations. $^3He/^4He$ ratios of the hot spring waters except Osaek $CO_2$-rich hot spring water range from $0.1{\times}10^{-6}$ to $1.1{\times}10^{-6}$ which are plotted above the mixing line between air and crustal components. It means that the He gas in hot spring waters was originated mainly from atmosphere and crust sources, and partly from mantle sources. The Osaek $CO_2$-rich hot spring water shows $3.3{\times}10^{-6}$ in $^3He/^4He$ ratio that is 2.4 times higher than those of atmosphere. It provides clearly a helium source from the deep mantle. $^{40}Ar/^{36}Ar$ ratios of hot spring water are in the range of an atmosphere source.

Pilot-scale Applications of a Well-type Reactive Barrier using Autotrophic Sulfur-oxidizers for Nitrate Removal (독립영양 황탈질 미생물을 이용한 관정형 반응벽체의 현장적용성 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Lee, Kyu-Yeon;Moon, Hee-Sun;Kim, Yang-Bin;Woo, Nam-C.;Lee, Jong-Min;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.40-46
    • /
    • 2009
  • The applicability of a well-type autotrophic sulfur-oxidizing reactive barrier (L $\times$ W $\times$ D = $3m\;{\times}\;4\;m\;{\times}\;2\;m$) as a long-term treatment option for nitrate removal in groundwater was evaluated. Pilot-scale (L $\times$ W $\times$ D = $8m\;{\times}\;4\;m\;{\times}\;2\;m$) flow-tank experiments were conducted to examine remedial efficacy of the well-type reactive barrier. A total of 80 kg sulfur granules as an electron donor and Thiobacillus denitrificans as an active bacterial species were prepared. Thiobacillus denitrificans was successfully colonized on the surface of the sulfur granules and the microflora transformed nitrate with removal efficiency of ~12% (0.07 mM) for 11 days, ~24% (1.3 mM) for 18 days, ~45% (2.4 mM) for 32 days, and ~52% (2.8 mM) for 60 days. Sulfur granules attached to Thiobacillus denitrificans were used to construct the well-type reactive barrier comprising three discrete barriers installed at 1-m interval downstream. Average initial nitrate concentrations were 181 mg/L for the first 28 days and 281 mg/L for the next 14 days. For the 181 mg/L (2.9 mM) plume, nitrate concentrations decreased by ~2% (0.06 mM), ~9% (0.27 mM), and ~15% (0.44 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. For the 281 mg/L (4.5 mM) plume, nitrate concentrations decreased by ~1% (0.02 mM), ~6% (0.27 mM), and ~8% (0.37 mM) after $1^{st}$, $2^{nd}$, and $3^{rd}$ barriers, respectively. Nitrate plume was flowed through the flow-tank for 49 days by supplying $1.24\;m^3/d$ of nitrate solution. During nitrate treatment, flow velocity (0.44 m/d), pH (6.7 to 8.3), and DO (0.9~2.8 mg/L) showed little variations. Incomplete destruction of nitrate plume was attributed to the lack of retention time, rarely transverse dispersion, and inhibiting the activity of denitrification enzymes caused by relatively high DO concentrations. For field applications, it should be considered increments of retention time, modification of well placements, and intrinsic DO concentration.

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

The Recovery of Left Ventricular Function after Coronary Artery Bypass Grafting in Patients with Severe Ischemic Left Ventricular Dysfunction: Off-pump Versus On-pump (심한 허혈성 좌심실 기능부전 환자에서 관상동맥우회술시 체외순환 여부에 따른 좌심실 기능 회복력 비교)

  • Kim Jae Hyun;Kim Gun Gyk;Baek Man Jong;Oh Sam Sae;Kim Chong Whan;Na Chan-Young
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.116-122
    • /
    • 2005
  • Background: Adverse effects of cardiopulmonary bypass can be avoided by 'Off-pump' coronary artery bypass (OPCAB) surgery. Recent studies have reported that OPCAB had the most beneficial impact on patients at highest risk by reducing bypass-related complications. The purpose of this study is to compare the outcome of OPCAB and conventional coronary artery bypass grafting (CCAB) in patients with poor left ventricular (LV) function. Material and Method: From March 1997 to February 2004, seventy five patients with left ventricular ejection fraction (LVEF) of $35\%$ or less underwent isolated coronary artery bypass grafting at our institute. Of these patients, 33 patients underwent OPCAB and 42 underwent CCAB. Preoperative risk factors, operative and postoperative outcomes, including LV functional change, were compared and analysed. Result: Patients undergoing CCAB were more likely to have unstable angina, three vessel disease and acute myocardial infarction among the preoperative factors. OPCAB group had significantly lower mean operation time, less numbers of total distal anastomoses per patient and less numbers of distal anastomoses per patient in the circumflex territory than the CCAB group. There was no difference between the groups in regard to in-hospital mortality $(OPCAB\; 9.1\%\;(n=3)\;Vs.\;CCAB\;9.5\%\;(n=4)),$ intubation time, the length of stay in intensive care unit and in hospital postoperatively. Postoperative complication occurred more in CCAB group but did not show statistical difference. On follow-up echocardiography, OPCAB group showed $9.1\%$ improvement in mean LVEF, 4.3 mm decrease in mean left ventricular end-diastolic dimension (LVEDD) and 4.2 mm decrease in mean left ventricular end-systolic dimension (LVESD). CCAB group showed $11.0\%$ improvement in mean LVEF, 5.1 mm decrease in mean LVEDD and 5.5 mm decrease in mean LVESD. But there was no statistically significant difference between the two groups. Conclusion: This study showed that LV function improves postoperatively in patients with severe ischemic LV dysfunction, but failed to show any difference in the degree of improvement between OPCAB and CCAB. In terms of operative mortality rate and LV functional recovery, the results of OPCAB were as good as those of CCAB in patients with poor LV function. But, OPCAB procedure was advantageous in shortening of operative time and in decrease of complications. We recommend OPCAB as the first surgical option for patients with severe LV dysfunction.

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

Analysis of the Characteristics of Water Quality Difference Occurring between High Tide and Low Tide in Masan Bay (만조와 간조시 마산만 수질의 농도차 발생 특성의 분석)

  • Yoo, Youngjin;Kim, Sung Jae
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.102-113
    • /
    • 2019
  • Slack-tide sampling was carried out at 6 stations at high and low tide for a tidal cycle during spring tide of the early summer (June) and summer (July, August) of 2016 to determine the difference of water quality according to tide in Masan Bay, Korea. The mixing regime of all the water quality components investigated was well explained through the correlation with SAL. In the early summer and summer, TURB, DSi and NNN which mainly flow into the bay from the streams and SS, COD, AMN and $H_2S$ which mainly indicate the internal sink and source materials have a property of conservative mixing and non-conservative mixing, respectively. The conservative mixing showed a good linear relationship of the water quality between high and low tide, and the non-conservative mixing showed a variation of different pattern each other. Factor analysis performed on the concentration difference data sets between high and low tide helped in identifying the principal latent variables for them. In early summer, multiple effects (tidal action, natural influx and internal sinks and sources etc.) acted in combination for the differences to be distributed evenly in four factors (VF1~4), since there were few allochthonous inputs as a low-water season. On the contrary, in summer, the parameters showing large concentration difference at ST-1 affected by stream water were concentrated in one factor (VF1) and clearly distinguished from the parameters affected by the internal sinks and sources. In fact, there is no estuary (bay) that always maintains steady state flow conditions. The mixing regime of an estuary might be changed at any time due to the change of flushing time, and furthermore the change of end-member conditions due to the internal sinks and sources makes the occurrence of concentration difference inevitable. Therefore, when investigating the water quality of the estuary, it is necessary to take a sampling method considering the tide to obtain average water quality data.