• Title/Summary/Keyword: 평가 일치도

Search Result 2,349, Processing Time 0.047 seconds

Development of BARS for Evaluation of Computer Programmers (컴퓨터 프로그래머의 직무수행 평가를 위한 행동기술척도(BARS) 제작)

  • 김명소;김호동
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2000.06a
    • /
    • pp.89-115
    • /
    • 2000
  • The present study attempts to (1) identify the critical dimensions that affect job performance of computer programmers and (2) clarify the specific behaviors that are related to each performance dimension, and measure them fairly and accurately. In particular, this study focus on producing a Behaviorally anchored Rating Scales (BARS) with a high level of acceptability by both raters and rates. 422 computer programmers from 8 companies participated in the process of developing the scale, which consisted of typical 5 phases. The results demonstrated that 13 performance dimensions were derived and the final job performance rating scale was made by vertically arraying 5 representative behavior anchors order by their scale value for each of 13 dimensions.

  • PDF

Enhanced latitude for digital projection radiography (디지털 투시촬영의 관용도 향상)

  • Han, Seung-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.98-101
    • /
    • 2002
  • 대조도와 관용도사이의 손실 교환은 투사 방사선 촬영에 있어서 잘 알려져 있고 또한 오랫동안 지속되어온 영상의 질에 있어서의 제약이었다. 전자적인 영상획득의 도입으로 한 영상 내에 넓은 영역의 X-Tay 노출을 포획하는 것이 가능해 졌다. 그러나, 진단에 필요한 세부영역 들을 위해 적절한 대조도를 유지하는 반면, 일반적으로 기대되는 관용도 범위 이외의 정보가 시각화 되어지는 것과 같은 영상의 rendering과 displaying의 문제가 남아 있었다. 이 문서에 묘사되는 EVP(Enhanced Visualization Processing)는 이 문제를 중점적으로 다룬다. 방대한 진단용 CR 영상 데이터베이스로부터 선택된 14개의 검사유형 당 각각 5개의 영상들을 포함한, 총 70개의 영상들을 사용하여 임상 보고서가 제출되었다. 각 영상에 대해, control rendering은 현재 개발되어 있는 automatic tone scaling algorithm(자동 톤 스케일 알고리즘)에 의해 생성되었고, test rendering은 그 control of image에 EVP를 인가함에 의해 생성되었다. 10명의 radiologist들은 각자 개별적으로 140개의 이미지들(70개의 test renderings와 70개의 control renderings)을 9점의 진단 상의 품질 척도로 평가했다. EVP는 세부 대조도의 부당한 손실 없이 증가된 노출 관용도를 제공했다. 많은 영상에서 EVP는 과소 투과 영역에서의 정보의 손실을 줄여주고, 반면 과다 투과 영역의 밝게 빛나는 현상을 실제적으로 감소시켰다. 진단상의 품질 평가는 EVP image와 control image 모두 평균적으로 높았다. 그럼에도 EVP images의 평균 등위는 control image의 그것보다 1 단계 완전히 높은 범위에 있는 것으로 평가되었다. 쌍으로 그 영상들을 보면, EVP images의 76%가 일치하는 control images의 평가 단계보다 1 또는 그 이상 높은 범주인 것으로 평가되었고, 반면 control image의 6% 만이 일치하는 EVP 영상보다 우수한 것으로 평가되었다. 유사한 결과가 연구된 14개의 검사유형에 대해 획득되었다.

  • PDF

Development of BARS for Evaluation of Computer Programmers (컴퓨터 프로그래머의 직무수행 평가를 위한 행동기술척도(BARS) 제작)

  • Kim, Myoung-So;Kim, Ho-Dong
    • Survey Research
    • /
    • v.1 no.2
    • /
    • pp.89-115
    • /
    • 2000
  • The present study attempts to (1) identify the critical dimensions that affect job performance of computer programmers and (2) clarify the specific behaviors that are related to each performance dimension, and measure them fairly and accurately. In particular, this study focus on producing a Behaviorally Anchored Rating Scales(BARS) with a high level of acceptability by both raters and ratees. 422 computer programmers from 8 companies participated in the process of developing the scale, which consisted of typical 5 phases. The results demonstrated that 13 performance dimensions were derived and the final job performance rating scale was made by vertically arraying 5 representative behavior anchors ordered by their scale value for each of 13 dimensions.

  • PDF

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

한국호스피스 표준화 기준(시행년도 : 1999년~2006년)

  • Korea Hospice Association
    • Korean Journal of Hospice Care
    • /
    • v.6 no.1
    • /
    • pp.100-107
    • /
    • 2006
  • 본회 소속 호스피스 기관은 PETAFO 기준에 따라 자격 등급을 평가한다. 평가는 최초 가입 시와 가입 후 1년마다 정기적으로 시행하고, 등급은 호스피스 형태별로 평가 종합점수에 따라 구분한다. 평가기준은 시행년도에 따라 변동될 수 있다. 자격등급을 평가하는 목적은 첫째, 우리나라 특성에 맞는 최상의 활동이 각 호스피스 형태에 따라 일정하게 유지되고, 둘째로 세계보건기구가 요구하는 수준과 일치시킴으로써 세계가 인정하는 양질의 호스피스 활동을 펼쳐나가는데 있다. 평가방법은 아래 질문 형식에 따라 각 기관 대표자 명의로 답변서를 작성하고 관련 자료를 첨부하여 제출하면 서류심사 및 실사로 이루어진다. 평가결과는 본회 회보와 호스피스 관련 언론지를 통해 발표한다.

  • PDF

Evaluation of Combustion Mechanism of Droplet Cluster in Premixed Spray Flame by Simultaneous Time-Series Measurement (동시 시계열 계측에 의한 예혼합 분무화염 내 유적군 연소기구의 평가)

  • Hwang, Seung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.442-448
    • /
    • 2009
  • To evaluate the combustion mechanism of each droplet cluster downstream of the premixed spray flame, the simultaneous time-series measurements were conducted by using optical measurement system consisting of laser tomography, multi-color integrated Cassegrain receiving optics (MICRO) and phase Doppler anemometer (PDA). Furthermore, the group combustion number of droplet cluster was estimated experimentally, and the combustion mechanism of droplet cluster was examined applying the theoretical analysis. The group combustion number, $G_c$, was experimentally estimated about all droplet cluster verified by planar images, and it was classified into the internal group combustion mode and the external group combustion mode according to the theoretical analysis. It is found that there are cases in which the group combustion number estimated experimentally for droplet cluster agree or disagree with the classification by theoretical analysis. The reason of disagreement is considered due to that the group combustion number was only estimated by the geometrical arrangement of droplets in cluster, and that the actual phenomenon is three-dimensional but the measurement system is two-dimensional.

Discordance between Tuberculin Skin Test and Interferon-gamma Release Assays for Diagnosis of Tuberculosis Infection in Korean Children (국내 소아 결핵감염 진단에서의 결핵피부반응 검사와 Interferon-gamma Release Assay (IGRA)의 비교 연구)

  • Yoo, Reenar;Kim, Joon-Il;Kim, Seohee;Lee, Jina
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • Purpose: There is a the great diagnostic challenge in pediatric tuberculosis especially in high burden setting. The purpose of this preliminary study is to evaluate the agreement between tuberculin skin test (TST) and interferon-gamma release assay (IGRA) including T-SPOT$^{(R)}$.TB and QuantiFERON$^{(R)}$-TB Gold (QFT-G) in Korean children. Method: This retrospective study included children and adolescents who visited to Asan Medical Center to evaluate tuberculosis infection using at least two assays of TST, T-SPOT.TB and QFT-G, from January 2014 to April 2015. Results: A total of 20 patients were included, whose median age was 13.3 years (range, 3.8-18.1 years), and all of them had history of BCG vaccination. Eleven patients had underlying diseases including 7 patients with immunosuppressant medication. The concordance rate between T-SPOT.TB and QFT-G was 90%. However, the concordance rate between TST and T-SPOT.TB was 50%, and between TST and QFT-G was 42.9%. Specificity for the diagnosis of tuberculosis infection of T-SPOT.TB, QFT-G, and TST was 93.3%, 86.7%, and 58.3%, respectively. Conclusions: Although there was a discrepancy between TST and IGRA to diagnose tuberculosis, agreement between T-SPOT.TB and QFT-G was relatively high. Further prospective study to validate the clinical usefulness of each assay for immunologic evidence of tuberculosis infection in Korean children will be mandatory.

DETECTION OF OCCLUSAL CARIES USING LASER FLUORESCENCE (레이저 형광법의 교합면 우식증 탐지 효과)

  • Kim, Chang-Gi;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.600-606
    • /
    • 2002
  • The purpose of this study was to evaluate the diagnostic validity of an incipient occlusal caries using argon laser fluorescence. Extracted human premolars and molars with enamel carious lesion of occlusal surface were assessed using visual examination, visual examination with probing, argon laser fluorescence and histologic depth of carious lesion. The results in each of all the three detection methods were compared to the assessment of histologic depth of carious lesion using polarized microscope. The results from the present study can be summarized as follows; 1. There was highly correlation between the histologic depth of occlusal caries and all three detection methods(P<0.01). 2. The reproducibility(kappa value) of the visual examination, visual examination with probing and argon laser fluorescence between the histologic depth of occlusal caries was 0.189, 0.128, 0.472. The highest correlation was seen between detection of occlusal caries by argon laser fluorescence and histologic scores by polarized microscope. The results from this study indicated that argon laser fluorescence considered to be accurate and reliable method in detecting occlusal caries.

  • PDF

Comparison of Face-to-Face Interview Questionnaires and Medical Records Data for Smoking Habits in Lung Cancer Patients (폐암 환자들의 일대일 설문조사와 의무기록의 흡연 습관 비교)

  • Lee, Eui-Cheol;Ryu, Jeong-Seon;Kim, Hyun-Jung;Cho, Jae-Hwa;Kwak, Seoung-Min;Lee, Hong-Lyeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • Background: This study evaluated the accuracy of smoking habit from the data obtained from the medical records of lung cancer patients against the data obtained form face-to-face interview questionnaires Methods: The smoking habits of 225 lung cancer patients were categorized into never smoked, ex-smoker and current smoker in face-to-face interview questionnaire and medical record taken at the time of admission for a diagnosis. The overall agreement between two sources was evaluated. The factors affecting the disagreement between two sources and the level of data omission of the smoking habits in medical records were analyzed suing multiple logistic regression. Results: The smoking habit between two sources showed moderate overall agreement(Kappa $({\kappa})=0.60$). The lowest agreement was observed in the ex-smokers(${\kappa}=0.49$). Multivariate analysis revealed an age of 65 or older to be a statistically significant factor associated with the increasing disagreement risk compared with those 64 or younger (OR 3.02; 95% CI 1.58-5.80). The omission rate of smoking habits in the medical records was 18.2%. Adenocarcinoma was shown to be a statistically significant factor of associated with an increasing omission rate compared with squamous cell carcinoma (OR 3.00; 95% CI 1.19-7.59). Conclusion: The smoking habits obtained from medical record moderately reflect their true behavior. However, the smoking habit data from medical record should be used with caution when being used in a clinical study or cohort study of lung cancer.

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.