• Title/Summary/Keyword: 편심도

Search Result 612, Processing Time 0.023 seconds

A Study on Eccentric Joint of K-type Gusset-Tube Connection (K형 가셋트-강관 접합부의 편심접합에 관한 연구)

  • Kim, Woo Bum;Kim, Kap Sun;Chung, Soo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.81-89
    • /
    • 2001
  • Experiments and the parametric based on finite element model were conducted to investigate the behavior and strength of a gussettube connection concerned with eccentricity and selenderness ratio. Because of limitations in loading capacity the specimens were fabricated with 1/3 scale of full size. Of primary interest here are the ultimate strength of connections having eccentricity caused by lateral loads. As a result the effect of eccentricity on the buckling strength was examined and the validity of the finite element model adopted in this study was verified through comparing with test results.

  • PDF

Modal Characteristics of a Structure with Stiffness and Damping Eccentricit (강성 및 감쇠 비대칭 구조물의 모드 특성)

  • 김진구;방성혁
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.421-432
    • /
    • 2002
  • In this study the modal characteristics and responses of an asymmetric structure with added viscoelastic dampers were investigated for design parameters such as eccentricity of stiffness and added dampers, the loss factor of the damping materials used. For modal characteristics, variation of the quantities such as natural frequencies, modal damping ratios, modal participation factors, and dynamic amplification factors were observed, and displacements at flexible and stiff edges, and at center of mass were obtained. Based on the results, the problem of the optimum damper distribution to minimize the torsional effects was addressed, and the proposed method for optimum damper distribution was applied to a multi-story structure to verify the applicability Finally the effect of viscous and viscoelastic dampers were compared by varying the loss factor of the viscoelastic material.

Eletromagnetic Field Analysis of SRM Due to Air Gap Eccentricity (Air Gap 편심에 따른 Switched Reluctance Motor의 전자기 가진력 해석)

  • 신현정;이동일;한승도
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.380.2-380
    • /
    • 2002
  • SRM(Switched Reluctance Motor) 내부의 Radial Force는 소음ㆍ진동의 주원인이 되는 가진력으로 작용하는 것으로 알려져 있다. 따라서 본 논문에서는 Radial Force의 주 요인인 Motor 내부의 Air Gap 편심에 따른 반경방향의 전자기 가진력을 전자장 수치해석을 통하여 해석하고 소음ㆍ진동에 미치는 영향을 분석하였다. Air Gap 편심량을 변화시켜 가면서 Stator, Rotor의 Local Force와 Gloval Force인 Torque Fluctuation을 해석하고 이를 실험 결과와 비교함으로서 해석결과의 타당성을 입증하였다.

  • PDF

The Development of Balancing Machine Using Hall Effect Sensor (홀 이펙트 센서를 이용한 밸런싱 머신 개발)

  • Jang In-Hun;Nam Won-Gi;Sim Gwi-Bo;O Se-Hun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.265-268
    • /
    • 2006
  • 회전 기기에서 회전체의 편심은 언밸런스를 유발하는데 이를 보정하는 밸런싱은 회전 기기에서의 방진 및 저소음 설계에 중요한 항목일 뿐 아니라 회전기기의 안정성과 사용수명에 큰 영향을 미치기 때문에 매우 중요하다. 이러한 밸런싱 머신을 구현하기 위하여 편심을 정확히 측정하여야 하는데, 본 논문에서는 기존의 벨런싱 기기에 일반적으로 사용되고 있는 계측 원리와는 다르게 홀-이펙트 센서를 이용하여 편심을 측정하는 방식을 제안함으로써 저가의 계측 시스템 구성이 가능함을 보이고, 밸런싱 신의 편심 측정부를 PC통신을 이용하여 제어하고자 한다.

  • PDF

An Evaluation of Blast Resistance Capacity of RC Columns under Eccentric Load (편심하중을 받는 철근콘크리트 기둥의 폭발 저항성 평가)

  • Kim, Han-Soo;Lee, Jae-Yong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.148-151
    • /
    • 2011
  • 현재 방폭설계 관련 설계지침은 기둥제거시나리오를 이용한 대체하중경로법을 주로 적용하고 있지만, 실제로 폭발이 발생하였을 때 기둥의 완전한 파괴가 일어나지 않을 경우 이 방식을 적용하는 것은 적합하지 않다. 따라서 본 논문에서는 비선형 동적 해석 프로그램인 AUTODYN을 이용해 편심하중을 받는 철근 콘크리트 기둥의 잔존 폭발 저항 성능을 평가하는 방식을 제안하였다. 해석결과를 비교해보면 TNT양과 축하중이 클수록 철근콘크리트 기둥의 잔존 폭발 저항 성능이 감소되었다. 이것은 폭발이 발생하기전의 기둥의 편심하중에 의한 응력상태에 따라 폭발 저항 성능이 달라짐을 알 수 있다.

  • PDF

Vibration Control of Asymmetric Buildings Using Viscoelastic Dampers (점탄성 감쇠기를 이용한 비대칭 건물의 진동제어)

  • 김진구;방성혁;이진수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • 본 연구에서는 진동제어를 목적으로 강성이 비대칭적으로 분포된 구조물에 점탄성 감쇠기를 설치할 경우 비틀림 응답을 줄이기 위한 감쇠기의 효과적인 배치방법에 관하여 연구하였다. 비대칭 구조물의 응답에 미치는 점탄성 감쇠기의 효과를 알아보기 위하여 비대칭 비비례감쇠시스템의 특성방정식을 유도하고, 고유치해석을 통해 감쇠기가 설치된 비틀림 건물의 거동특성을 파악하였다. 이를 바탕으로 강성 편심 및 진동수비에 따른 최적 감쇠 편심을 찾아 이를 3차원 그래프로 나타내었다. 이를 이용하여 비대칭건물에 감쇠기를 설치했을 때 같은 양의 감쇠기를 대칭으로 설치하였을 때 보다 그 효과가 더욱 향상되는 것으로 나타났다. 또한 비대칭 건물의 비틀림제어면에서 점탄성 감쇠기가 점점 감쇠기보다 우수한 것으로 나타났다.

  • PDF

Control of the Eccentric Building Using a TMD with Torsional Rigidity (비틀림 강성을 가지는 동조질량감쇠기를 이용한 편심건물의 제어)

  • Park, Yong-Koo;Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.65-72
    • /
    • 2012
  • In this stury, control performance of tuned mass damper (TMD) with torsional rigidity for an eccentric structure showing torsional responses is investigated. To this end, an eccentric structure subjected to earthquake excitation is used to evaluate the control performance of torsional TMD by varying installed location and torsional rigidity of TMD, To reduce computational time required for repetitive time history analysis of an example structure having non-proportional damping system due to TMD, an equivalent analytical model is used in this study. Torsional properties of TMD usually neglected in typical TMD are verified to be effective in reduction of torsional responses of the eccentric structure. In the case of eccentric structures, it has been seen that the center of a plane of a structure may not be optimal location of TMD.

Optical Performance Analysis of the Eye which it Follows in Iris Eccentricity (홍채 편심에 따른 눈의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.31-34
    • /
    • 2009
  • Purpose: We are to analyze optically how to affect the eye related with movement of the iris. Methods: Using the schematic eye to have the crystalline lens of the radial GRIN and the spherical GRIN forms that come to be planned in existing, the iris centre was moved 0.5 mm with nasal direction in order to be identical with the real eye. Also, considering that the iris centre move according to increase of the pupil size, the iris centre was moved 0.4 mm with temporal direction to analyze the optical performance change of the eye respectively. Results: Because of decrease in the spherical aberration, the schematic eye with nasal direction 0.5 mm eccentricity of the iris showed a different consequence plentifully compared with the performance of the real eye. Besides, the schematic eye with temporal direction 0.4 mm eccentricity of the iris showed that the spherical aberration somewhat increased. Conclusions: In case of design of the schematic eye with the similar real eye performance which the iris centre was moved 0.5 mm with nasal direction, we need to research about aspheric coefficient of optical constants of each refracting surface considering the performance change of a spherical aberration, a peripheral power error and astigmatism etc, owing to change of the real eye hence to be affected by the iris movement.

  • PDF

Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core (편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Kim, Sung-Yong;Kim, Kyung-Nam;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.490-498
    • /
    • 2020
  • In this study, the seismic performance of low-rise piloti buildings with eccentric core (shear wall) positions was analyzed and reviewed. A prototype was selected among constructed low-rise piloti buildings with eccentric cores designed based on KBC2005. The seismic performance of the building showed plastic behavior in the X-direction and elastic behavior in the Y-direction. The inter-story drift is larger than that of a concentric core case and has the maximum allowed drift ratio. The displacement ratio of the first story is much larger than that of upper stories, and the frame structure in the first story is vulnerable to lateral force. Therefore, low-rise piloti buildings with eccentric cores need to have less lateral displacement, as well as reinforcement of the lateral resistance capacity in seismic design and seismic retrofit.

Bearing Strength of Steel Baseplate under Eccentric Loads (편심축력(偏心軸力)을 받는 철골구조(鐵骨構造) 주각부(柱脚部)의 지압강도(支壓强度))

  • Choi, Mun Sik;Min, Byung Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.683-691
    • /
    • 2003
  • Recently, the steel has been increaseingly used as an integrated part of high-rise buildings, which often composed of steel structures, steel reinforced concrete structures and composite structures. The steel base is designed to transfer the stresses induced from steel column to the reinforced concrete footing through the base plate. However, in the design of steel structures and steel reinforced concrete structure, it is generally difficult to evaluate the bearing strength of the steel base subjected to large axial force. Furthermore, the material used in steel base is quite different from those used in other connections and a load transferring mechanism of steel base is very complicated in nature. Therefore, a special attention must be placed in design and construction of steel base. In generally, the bearing strength test and research of the steel base subjected to concentrated load are carried out. But, in the design of the structures, uniaxial eccentric load is loaded to the steel base of the steel structures. In this research, the bearing strength and the me of failure considering eccentric loads and eccentric length, were experimented when eccentric load is loaded to the steel base of steel structures. Based on the test results, a basic design reference is suggested for a reasonable design of steel structures, steel reinforced concrete structures and composite structures.