• 제목/요약/키워드: 펠릿이송장치

검색결과 1건 처리시간 0.014초

펠릿 이송용 이젝터의 구동노즐 구성에 따른 유동 및 이송특성에 관한 실험적 연구 (Effect of Primary Nozzle Configuration on the Flow and Transfer Characteristics in an Ejector System for Pellet Transfer)

  • 김금규;김의수;강신명;이지근;노병준
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.49-59
    • /
    • 2008
  • The effects of design parameters on the pellet transport rate in the ejector system which is widely used in the production processes of automotive parts were investigated experimentally. The primary nozzle geometry, the area ratio (R) of nozzle exit cross-sectional area to mixing chamber cross-sectional area and the distance (S) from primary nozzle exit to mixing chamber entrance were considered as the design parameters. The area ratios of the primary nozzle were varied from R=0.10 to R=0.25, 0.30, 0.40 and 0.55. The primary nozzle was positioned at the non-dimensional distance (S/D) of 1.30, 1.87, 2.44, 3.00 and 3.75, normalized using the mixing chamber diameter (D). The design parameters were determined to run with high efficiency by measuring the pellets transport rate. The geometry and the area ratio (R) of the primary nozzle had an effect on the pellet transport rate of the ejector system, and the area ratio of R=0.3 was carefully selected after taking the minimum fluidization velocity and transport rate of applied pellets into account. The higher pellet transport rate with the variation of the distance (S/D) was observed at S/D of 2.44.