• Title/Summary/Keyword: 페놀프탈레인

Search Result 17, Processing Time 0.021 seconds

A study on the false-positive reaction of Kastle-Meyer(KM) test and the application of KM reagent (Kastle-Meyer(KM) test의 위양성 반응과 시약 적용 방법에 관한 연구)

  • Kim, Chae-Lin;Kim, Chang-Yong;Kim, Min-Yeong;Yu, Je-Seol
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.139-146
    • /
    • 2020
  • Kastle-Meyer (KM) test is one of presumptive tests used to detect latent blood in crime scenes. While this method is more sensitive than others, false positive reaction can be shown where blood does not exist. In this study, we tried to suggest a new application method to solve this problem. Reaction time and aspect of reaction of this new method was compared with two conventional methods in order to identify the effectiveness and identifiability. As a result, there was no statistically significant difference in sensitivity between the methods. In addition, in case of blood with a dilution ratio of 5000:1 or less, positive reaction showed immediately, making it easy to distinguish the reaction from false positive reaction. However, it became difficult to distinguish them with the reaction time as the dilution ratio increased, and this phenomenon could be supplemented observing aspect of the reaction when using the new method. Therefore, this study suggested a new method for KM test that can be used more accurately in the field.

Prediction Model of Remaining Service Life of Concrete for Irrigation Structures by Measuring Carbonation (중성화 측정을 통한 콘크리트의 잔존수명 예측 모델)

  • Lee, Joon-Gu;Park, Kwang-Soo;Kim, Han-Joung;Lee, Joung-Jae
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.529-540
    • /
    • 2003
  • Recently, the researches on the durability design of concrete structures have been studied. As the examples, models to evaluate the service life prediction of the structure have been developed. The purpose of this article is to develop the model for predicting remaining service life. The final aim is to provide the user time for repairing the concrete structures. In addition, it makes possible to maintain the concrete structure economically. 70 reservoirs out of the inland concrete structures were selected and concrete structures of their components were surveyed. Two methods were used for measuring carbonation; TG/DTA method and Phenolphtalein indicator and, the value of pH was measured by the pH meter, After deriving correlations of calcium carbonate and used year, duration from completion year to 2002, pH value, and concrete cover depth the model was developed for predicting remaining service life by measuring data as small as possible. The conventional models had been developed on the basis of experiment data obtained from the restricted lab environment like as carbon gas exposure. On the other hand this model was developed on the basis of measuring data obtained from the real field that the complex deterioration actions are occurred such as freezing and thawing, carbonation, steel corrosion, and so on. The reliability of the developed model will be evaluated high in this point and this model can help to maintain concrete structures economically by providing the manager time to repair the deteriorated concrete structures in site of facility management.

Evaluation of Characteristics of G-class Cement for Geothermal Well Cementing (지열 발전정 시멘팅을 위한 G-class 시멘트 특성 평가에 관한 연구)

  • Won, Jongmuk;Jeon, Jongug;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.29-38
    • /
    • 2013
  • The G-class cement is commonly used in practice for geothermal well cementing in order to protect a steel casing that is designed to transport hot water/steam from deep subsurface to ground surface during operating a geothermal power plant. In order to maintain optimal performance of geothermal wells, physical properties of the cementing material should be satisfactory. In this paper, relevant factors (i.e., groutability, uniaxial compression strength, thermal conductivity and free fluid content) of the G-class cement were experimentally examined with consideration of various water-cement (w/c) ratios. Important findings through the experiments herein are as follows. (1) Groutability of the G-class cement increases by adding a small dose of retarder. (2) There would be a structural defect caused when the w/c ratio is kept higher in order to secure groutability. (3) Thermal conductivity of the G-class cement is small enough to prevent heat loss from hot steam or water to the outer ground formation during generating electricity. (4) The G-class cement does not form free water channel in cementing a geothermal well. (5) The Phenolphthalein indicator is applicable to the distinction of the G-class cement from the drilling mud.

Determination of fuel marker in petroleum products using GC-MS (GC-MS를 이용한 석유제품 중의 식별제 분석)

  • Youn, Ju Min;Doe, Jin Woo;Yim, Eui Soon;Lee, Jung Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1073-1080
    • /
    • 2018
  • There are several types of petroleum products used for the fuel oil, according to their respective quality standards, grades and usage. Depending on the degree of oil tax rate by country, even the same petroleum products will have price gap. The illegal mixing of cheap petroleum products, which are subject to the lower tax rate, with relatively expensive transportation fuel causes problems such as tax evasion, environmental pollution and vehicle breakdown. In order to prevent illicit production and mixing of these different petroleum products, a small amount of markers are legally added to specific petroleum products. In Korea, markers are introduced and used to prevent illegal activity that kerosene used as fuel for house and commercial boiler are mixed with automotive diesel fuels, and marker contents are analyzed to use UV-Vis spectrophotometer and high performance liquid chromatography (HPLC). In this study, we have developed a method to qualitatively and quantitatively determine the marker added to petroleum products by gas chromatography-mass spectrometry (GC-MS) without adding developing reagent or sample pre-treatments.

Evaluation of $CO_2$ Uptake Using $CO_2$ Philic Adsorbents in Mortar (친 이산화탄소 흡착제를 이용한 모르타르 내 이산화탄소 흡수능 평가)

  • Park, Hyojeong;Jang, Junwon;Lee, Jihyun;Park, Jaewoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.11-17
    • /
    • 2012
  • This study focused on application of various $CO_2$ philic adsorbents with amine to improve $CO_2$ uptake in mortar. TGA, phenolphthalein method, FT-IR XRD, and FE-SEM analysis methods were used to evaluate $CO_2$ capture in mortar. When $CO_2$ philic adsorbents was used, $CO_2$absorption efficiency was improved maximum of 58.5%. Carbonation depth was increased 3 times compared with original mortar. Chemical reactions between bicarbonate ion, $CO_2$, $CO_2$ philic adsorbents aqueous solution, and $Ca^{2+}$ ions dissolved from cement formed $CaCO_3$ in the mortar. Therefore, impregnation of the $CO_2$ philic adsorbent on the surface of the mortar can increase the adsorbed $CO_2$.

Thrombin Detection with Tetrabromophenolphthalein Ethyl Ester Adsorbed on Aptamer-attached Conductive Polymer (전기전도성 고분자 위에 고정된 압타머에 흡착된 테트라브롬페놀프탈레인 에틸 에스테르를 이용한 트롬빈 검출)

  • Chung, Saeromi;Noh, Hui-Bog;Shim, Yoon-Bo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.4
    • /
    • pp.134-140
    • /
    • 2016
  • An aptamer-based biosensor using a new redox indicator has been examined for the electrochemical detection of thrombin. The aptamer modified primary aliphatic amine was covalently immobilized onto poly-(5,2':5',2"-terthiophene-3'-carboxylic acid) (polyTTCA) layer. Tetrabromophenolphthalein ethyl ester (KTBPE) was interacted to aptamer and used as an electrochemical indicator. Prior to the detection, the oxidation reaction of KTBPE onto aptamer modified layer was also investigated using differential pulse voltammetry. The characterization of the final sensor (KTBPE/aptamer -polyTTCA) was performed by voltammetry, QCM, and ESCA. After binding of thrombin onto KTBPE/aptamer based sensor, the peak signal of KTBPE was gradually decreased. The sensor exhibited a dynamic range between 10.0 and 100.0 nM with the detection limit of $1.0{\pm}0.2nM$.

Spectrophotometric, pH-metric and Conductometric Studies on Some 3-Arylhydrazone Derivatives of (2-Thenoyl) Ethylpyruvate) (2-Thenoyl Ethylpyruvate의 몇 가지 3-Arylhydrazone 유도체에 대한 분광광도법, pH 및 전도도법 연구)

  • El-Dossoki, F. I.;El-Seify, F. A.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.2
    • /
    • pp.99-106
    • /
    • 2006
  • The electronic absorption spectra of [3-(2-thenoyl) 3-(p-NO2-phenylhydrazone) ethyl pyruvate] (I), p-Br (II) and p-CH3 (III) were studied in ethanol and the spectra comprise four absorption bands which assigned to the corresponding electronic transition. The pK values of these compounds have been determined spectrophotometrically and pH-metrically, the results shown that the interval range for color change of compound (I) is (8-10) similar to that of phenolphethalin indicator, indicating that this compound can be used as acid-base indicator. The successive stability constants of the compounds under study with some transition elements (Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO2(II), La(III) and Zr(IV) have been determined pH- metrically. Stoichiometric complexes with ratios 1:1 and 1:2 (M: L) were formed for all metals. The pK of the three derivatives and the values of the stability constant (logK) of the complexes have the order; III > II > I. Also conductometric titrations have been carried out and the results show that this titration can be used for determination of both the metal ion and the ligand concentrations by each others.