• Title/Summary/Keyword: 펌프 제어

Search Result 553, Processing Time 0.02 seconds

Flow Characteristics of Central-Driven Ejector with Design Parameters (중앙구동 이젝터의 설계변수에 따른 유동특성)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.645-651
    • /
    • 2015
  • The objective of this study is to experimentally investigate the effect of design parameter on the mass ratio of a central-driven ejector. The design parameters are the primary nozzle area and distance ratios, diffuser exit-area ratio and mixing-tube length ratio. The experimental setup was an open-loop continuous circulation system which has a movable nozzle ejector, an electric motor-pump, a water tank, a control panel and high-speed camera unit. We calculated the mass ratio using the measured primary and suction-flow rates with the experimental parameter of primary water-flow rate or pressure. The results showed that the mass ratio increased with the primary nozzle distance ratio and mixing tube length ratio, while the mass ratio decreased with the primary nozzle-area ratio and diffuser exit-area ratio.

Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation (시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Discharge variations of perforated hose and drip irrigation systems were examined to evaluate irrigation uniformity at different pressures and length of branch line. Evaluation using statistical uniformity indicated that button drippers performed at excellent level but drip tapes and drip hoses were a little lower level. Nominal discharge of drip irrigation systems showed at the high side within the range of regulating pressure provided by the manufacturer. It is desirable that the length of branch line for drip hose, drip tape, and button dripper should be limited to 50 m, 70 m, and 100 m, respectively. Irrigation uniformity of perforated hoses showed very low level. So it is recommended that the length of branch line for perforated hoses should be limited to $30{\sim}35m$.

3.125Gbps Reference-less Clock and Data Recovery using 4X Oversampling (4X 오버샘플링을 이용한 3.125Gbps급 기준 클록이 없는 클록 데이터 복원 회로)

  • Jang, Hyung-Wook;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.10-15
    • /
    • 2006
  • In this paper, a clock and data recovery (CDR) circuit for a serial link with a half rate 4x oversampling phase and frequency detector structure without a reference clock is described. The phase detector (PD) and frequency detector (FD)are designed by 4X oversampling method. The PD, which uses bang-bang method, finds the phase error by generating four up/down signal and the FD, which uses the rotational method, finds the frequency error by generating up/down signal made by the PD output. And the six signals of the PD and the FD control an amount of current that flows through the charge pump. The VCO composed of four differential buffer stages generates eight differential clocks. Proposed circuit is designed using the 0.18um CMOS technology and operating voltage is 1.8V. With a 4X oversampling PD and FD technique, tracking range of 24% at 3.125Gbps is achieved.

  • PDF

An Implementation of Smart Flowerpot made with 3D Printer and NodeMCU (3D 프린터와 NodeMCU를 사용한 스마트 화분의 구현)

  • Na, Chaebin;Choi, YeonWoong;Kim, SeKwang;Seo, JangGui;Hwang, Kitae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.231-237
    • /
    • 2017
  • This paper presents an implementation of a smart flowerpot which can adjust humidity and illumination automatically after monitoring the temperature, humidity, and illumination. We made a container of the flowerpot with a 3D printer and embedded a NodeMCU micro controller in it. We attached a temperature sensor, a humidity sensor, an illumination sensor, and a water pump to the NodeMCU. We developed a control program that adjusts humidity and illumination and ran it on the NodeMCU. Also we developed an Android application and set up an MQTT server. Using the MQTT server, the NodeMCU and the Android application can exchange messages which keep sensor values and commands. Using the Android application. the user can send the proper temperature, humidity, and illumination to the smart flowerpot and monitor the sensor values.

Dual-Mode Reference-less Clock Data Recovery Algorithm (이중 모드의 기준 클록을 사용하지 않는 클록 데이터 복원 회로 알고리즘)

  • Kwon, Ki-Won;Jin, Ja-Hoon;Chun, Jung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.77-86
    • /
    • 2016
  • This paper describes a dual-mode reference-less CDR(Clock Data Recovery) operating at full / half-rate and its operation algorithm. Proposed reference-less CDR consists of a frequency detector, a phase detector, a charge pump, a loop filter, a voltage controlled oscillator, and a digital block. The frequency and phase detectors operate at both full / half-rate for dual-mode operation and especially the frequency detector is capable of detecting the difference between data rate and clock frequency in the dead zone of general frequency detectors. Dual-mode reference-less CDR with the proposed algorithm can recover the data and clock within 1.2-1.3 us and operates reliably at both full-rate (2.7 Gb/s) and half-rate (5.4 Gb/s) with 0.5-UI input jitter.

Performance characteristics of inline mixing and coagulation system (인라인 혼화 및 응집 시스템의 성능특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.269-275
    • /
    • 2014
  • The objective of this study was to investigate the performance characteristics of an inline mixing and coagulation system for water treatment based on the process intensification concept. Three-stage inline mixing and coagulation system was composed of the reservoirs of source wastewater, the fixed quantity injection pumps of coagulants, the mixing and coagulation tubes, a sedimentation tank and a control panel. In the equal dosage of coagulant and coagulant aids, the turbidity removal with increasing the dosage of coagulant aids was about 3 times higher than that with increasing the dosage of coagulant. In the condition of the equal mixing and coagulation time, the turbidity removal of inline mixing and coagulation system was about 4.6 times higher than that of mechanical type.

Carbon tip growth by electron beam deposition (전자빔 조사에 의한 탄소상 탐침의 성장)

  • 김성현;최영진
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2003
  • Carbon tips were grown on Si cantilevers by applying an electron beam to them directly with Scanning Electron Microscope. A carbon tip was fabricated by aligning the electron beam directly down the vertical axis of Si cantilever and then irradiating a single spot on the cantilever for a proper time in the dominant atmosphere of residual gases generated by the oil of the diffusion pump. A number of control parameters for SEM, including exposure time, acceleration voltage, emission current, and beam probe current, were allowed to make various aspect ratio feature. The growth of carbon tips was not affected by the surface morphology of substrates. We could acquired the tip whose effective length is 0.5 $\mu\textrm{m}$, bottom diameter is 90 nm and cone half angle $3.5^{\circ}$ The growth technique of the high aspect ratio carbon tips on the tip-free cantilevers is available to reduce the complexities of fabricating sub-micron scale tips on the PZT thin film actuator integrated AFM cantilevers.

Development of O-Ring Measurement Systems of Muscular Meridians for objectification of Constitutional Diagnosis (체질 진단의 객관화를 위한 O-Ring 경근 계측시스템의 개발)

  • 정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.555-561
    • /
    • 1995
  • In this paper, the O-Ring Measurement System (O-R MS) has been designed to supplement such subectivity and apply to the diagnosis by constitution. A single chip microprocessor of Intel MCS-51 family has been used to control the O-R MS and process data with real time, and the O-R MS could measure the minute muscular strength, expanded width between fingers, and time of the measurement. Therefore the objective constitutional diagnosis is possible by the O-R MS. As a clinical testing for estimating credibility of O-R MS, the acupuncture points representing the constitution has been stimulated using a semiconductor laser stimulator and measure the muscular strength by the O-R MS. The result of clinical testing has been shown that the constitutional diagnosis with the O-R MS is proved highly precision of 96% and it is expected that the O-R MS can be used practically for the objective constitutional diagnosis.

  • PDF

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

I-Q Channel 12bit 1GS/s CMOS DAC for WCDMA (WCDMA 통신용 I-Q 채널 12비트 1GS/s CMOS DAC)

  • Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Kim, Soo-Jae;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.56-63
    • /
    • 2008
  • This paper describes a 12 bit 1GS/s current mode segmented DAC for WCDMA communication. The proposed circuit in this paper employes segmented structure which consists of 4bit binary weighted structure in the LSB and 4bit thermometer decoder structure in the mSB and MSB. The proposed DAC uses delay time compensation circuits in order to suppress performance decline by delay time in segmented structure. The delay time compensation circuit comprises of phase frequency detector, charge pump, and control circuits, so that suppress delay time by binary weighted structure and thermometer decoder structure. The proposed DAC uses CMOS $0.18{\mu}m$ 1-poly 6-metal n-well process, and measured INL/DNL are below ${\pm}0.93LSB/{\pm}0.62LSB$. SFDR is approximately 60dB and SNDR is 51dB at 1MHz input frequency. Single DAC's power consumption is 46.2mW.