Search Result 84, Processing Time 0.03 seconds

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Pump operation based on pressure sensors for the damage reduction of water distribution system (상수도관망의 피해저감을 위한 센서기반 펌프운영)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.200-200
    • /
    • 2019
  • 본 연구에서는 실제 가압장 및 가압장후단부의 상수도관망에 발생가능한 수충격해석을 수행하고 신뢰성해석을 수행하여 파괴확률을 정량적으로 산정하였다. 이를 위해 가압장의 펌프운영조건을 다르게 적용하였고 관말단부의 압력센서를 이용하여 토출압을 선택적으로 운영하면 수충격의 규모도 작아지고 파괴확률도 대폭 줄어드는 것을 확인할 수 있었다. 가압장의 토출압을 선택적으로 운영하기 위해서는 관말단부에 필수적으로 충분한 수압이 존재해야하며 이를 위해서 실시간 모니터링이 가능한 압력계를 설치하게 된다. 이 압력계로부터 수신되는 데이터를 통하여 펌프의 운영이 이루어지고 최소한의 에너지 사용을 통해 효율을 증대하고 피해율도 저감하게 된다. 본 연구에서 개발된 센서기반 펌프운영시스템이 적용된 실제 상수도관망은 현재 가압장의 운영조건으로 24시간 75m의 펌프 토출압을 유지하고 있으며 관말단부의 수용가에 충분한 수압이 전달되고 있다. 가압장의 고압유지는 관말단부에 충분한 수압을 전달하기 위한 것이지만 상수도관망에서 누수와 시설물에 대한 많은 피해를 유발할 수 있다. 따라서 본 연구에서는 가압장의 펌프토출압을 75m와 60m로 선택적 운영을 할 수 있도록 프로그램을 개발하였다. 기존 가압장의 운영조건과 선택적 운영조건을 사용하여 수충격해석을 수행하였고 신뢰성해석모형을 사용하여 파괴확률을 정량적으로 산정할 수 있었다. 가압장의 운영조건을 최적화하여 효율은 증대하고 피해율을 저감할 수 있는 방법을 찾을 수 있었다. 이를 위해서 가압장의 인버터 설치는 물론이고 펌프의 최적운영을 위해 개발된 펌프운영 프로그램을 가압장 배전반에 장착하여 경제적인 운영이 될 수 있을 뿐만 아니라 실제 상수관망에서 과도한 수압으로 인해 발생할 수 있는 여러 가지 피해를 최소화할 수 있을 것으로 판단된다. 또한, 본 연구에서는 기존의 펌프장 토출압으로 운영되었을 때와 비교하여 에너지 절감율을 정량적으로 산정하여 비교분석하였다. 가압장 후단의 작은 마을을 대상으로 하여 절감된 전기요금은 적은 양이라 할 수 있겠으나 개발된 시스템을 전국에 적용한다면 에너지 절감으로 인한 경제적 파급효과는 크다고 할 수 있다.

  • PDF

Development of optimum pump operation technique for the damage rate reduction of water distribution system (상수도관망의 피해율 저감을 위한 가압장 최적운영기법 개발)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.373-380
    • /
    • 2019
  • In this study, the optimum pump operation technique is suggested to decrease the damage rate of water distribution system. Pump operation system was developed to achieve the effective pump operation. Pressure sensors which can communicate with pumps are installed at the end of water distribution system. Pump operation system can control the pressure of water pump according to data sent from the pressure sensors. Therefore, water distribution system can reduce the pressure and maintain enough pressure which can supply the demand of water users. For proving effectiveness of new system, reliability model was introduced to compare the results of damage rates between the maintaining high pressure and selective pressure in water pump. Unsteady analysis was conducted with several scenarios. And the results were used to calculate the probability of pipe breakage. From the results, it was found that new pump operation system can reduce the energy usage and probability of pipe breakage by applying to pumps.

Charge-pumped flyback-boost converter for charge balancing (차지펌프를 적용한 부스트 플라이백 컨버터 전하 균등화 회로)

  • Lee, Chun-Gu;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.183-184
    • /
    • 2015
  • 본 논문에서는 차지펌프를 적용한 부스트 플라이백 컨버터를 사용하여 연속 모드로 동작하는 전하 균등화 방법을 제안한다. 이 컨버터는 전압균형 상태일 때 부스트만 동작하므로 높은 효율을 가지며 전압불균형 상태일 때 플라이백이 동작하여 전압을 균등화시키는 특징을 지닌다. 이 때 차지 펌프를 적용한 플라이백을 사용하기 때문에 도통율에 따른 전압의 이득이 부스트와 동일하므로, 부스트 입출력 전압 변화에 자동으로 대응하며 가격과 효율 측면에서 우수하다. 제안된 회로의 동작 원리를 설명하고 400W급 하드웨어로 설계를 하여 검증하였다.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

Suggestion of a Model for Filling Coefficient of Hydraulic Cylinder in Concrete Pump (콘크리트펌프 유압실린더의 충진율 모델 제안)

  • Park, Chan-Kyu;Jang, Kyong-Pil;Jeong, Jae-Hong;Kwon, Seung-Hee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.195-202
    • /
    • 2016
  • In general, piston pumps are frequently used for concrete pumping. Filling coefficient signifies the ratio volume of a hydraulic cylinder to volume of concrete inside the cylinder. Therefore, it may be considered as a parameter directly affecting the flow rate and efficiency for concrete pumping. However, accurate analyses on this aspect have not yet been performed. In this paper, the data measured from horizontal pipeline pumping tests for 350m and 548m in length was analyzed to identify the relationships of rheological properties of concrete and stroke time with the filling coefficient. In addition, an equation allowing prediction of the filling coefficient from rheological properties of concrete and stroke time has been suggested.

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF

Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles (인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가)

  • Kim, Kyungwuk;Suh, Sang-Ho;Rakibuzzaman, Rakibuzzaman
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.