Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.

물 - 물熱펌프의 산業體 廢熱利용에 관한 시스템 設計와 經濟性

  • 조명제
    • Journal of the KSME
    • /
    • v.22 no.6
    • /
    • pp.471-476
    • /
    • 1982
  • 1.열펌프 시스템의 성능은 최적설계를 하므로서 이론적, Rankine C.O.P에 접근시킬 수 있다. 2.. 산업체 중저온 폐열회수이용에는 열펌프가 매우 유망하며 냉온수를 동시에 이용하는 경우는 더욱 유리하다. 3. 우리나라 산업계에서 보통 투자회수기간을 3년으로 본다면 전력시설용량을 500kw 이상의 산업용 소동력, 대동력의 경우 열펌프의 성적계수는 약 3.5 정도가 하한으로 볼 수 있다. 4. 공기 또는 물 열원의 가정용 열펌프는 전력비가 비싸므로 아직은 실용성이 없다.

  • PDF

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

Performance analysis simulation for domestic application of heat pump by using sea water heat source (해수열에너지를 이용한 히트펌프의 국내 적용을 위한 성능평가 시뮬레이션)

  • Lim, Seungtaek;Kim, Jungsik;Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.814-820
    • /
    • 2014
  • Due to the development of human civilization, industrialization and urbanization, the human race demanded the food, clothing and shelter as well as a comfortable living environment. For the purpose of this, the refrigeration and air conditioning part was carried out research and development. However, high oil prices and environmental pollution having problems in the 21st century cannot be overlooked. As an alternative, thermal system was designed using the heat pump to applied sea water heat source. In this paper, outside and sea temperatures are analysed in 2010 and carried out the performance analysis simulation at All water and All Air heat pump system by HYSYS program for domestic use. As a result, total average COP of the system is 3.37 from All Water system and All Air is 3.48. It showed that high performance confirmed in both system.

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

A Study on Partial Load Performance of Absorption Type Heat Pump for Waste Heat Recovery of Closed Cooling Water (기기냉각수 폐열회수용 흡수식 히트펌프의 부분부하 성능에 관한 연구)

  • Park, Byungchul;Kim, Taehyeong;Kim, Kwangsu
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.47-54
    • /
    • 2019
  • As absorption type heat pump for waste heat recovery is installed in combined cycle power plant for Energy Service Company, performance test is implemented to confirm the operation data on partial load. The operation data changes according to the heat pump operation on partial load are as follows. Total heat output increases, because waste heat of closed cooling water and a portion of LP steam from HRSG is supplied. But electric power output of steam turbine is reduced, because LP steam to steam turbine is reduced. And heat output from HP district heater and LP district heater is reduced, because HP turbine exhaust steam to HP district heater and LP district heater is reduced. On partial load operation, turbine output reduction is higher than the base load operation. Therefore, on partial load, heat pump should be operated in consideration of the heat output increase and electric power output reduction.

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.118-118
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M 냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler (G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K와 1st STG Temp. 80K를 Heat Load기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

게터조합펌프의 배기속도 측정

  • Kim, Yong-Deok;Park, Seok-Jun;Jo, Jeong;Yang, So-Hui;Park, Jong-Do;Ha, Tae-Gyun;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.206-206
    • /
    • 2012
  • 초고진공 시스템에 사용되는 조합펌프(게터펌프+이온펌프)의 배기속도를 측정하여 보고한다. 이 펌프는 좁은 공간 내에 설치가능 하고 비교적 큰 배기속도를 가지도록 설계되었다. 이온펌프는 소형(30 l/s) 이극형이며 게터펌프는 ZrVFe 합금의 모듈형태로 1개에서 3개까지 장착되도록 하였다. 이 펌프의 설계 성능을 검증하기 위하여 초고진공상태의 잔류기체 구성비에 가까운 기체조성비(수소 90%, 일산화탄소 10%)로 그 배기속도를 측정하였다. 배기속도는 미국진공학회 표준측정순서를 따랐으며 도달압력도 측정하여 보고한다.

  • PDF

Performance Test of a 7 tonf Liquid Rocket Engine Turbopump (7톤급 액체로켓엔진용 터보펌프 조립체 성능시험)

  • Kwak, Hyun Duck;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jinhan;Noh, Jun-Gu;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Jeong, Eunhwan;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeong-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • Performance tests of a turbopump for the developing 7-tonf liquid rocket engine were conducted. The performance of turbopump components and their power matching were measured and examined firstly under the LN2 and water environment. In the real propellant(LOX and kerosene) environment tests, design and off-design performances of turbopump were fully verified. During the off-design tests, turbopump running time was set the same as engine operating time and pump inlet pressure were set lower than nominal operating value in order to investigate pump suction capability. It have been verified that subject turbopump satisfies required performance - flow rate, head, suction performance and operational time - in the operating regime of developing liquid rocket engine.