• Title/Summary/Keyword: 펌프실험장치

Search Result 188, Processing Time 0.03 seconds

Development of solar powered water pump by using low temperature PCM -Equipment construction and experiments- (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구 개발(II) -장치의 구성 및 실험-)

  • 김영복;이양근;이승규;김성태
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.384-389
    • /
    • 2003
  • 전기가 공급되지 않는 농경지에 물을 공급하기 위해 태양열을 동력원으로 하고 저온에서 비등하는 물질을 작동물질로 하는 물펌프가 연구되어 왔다. 이와 관련하여 김 등(2002, 2003)은 펜탄을 작동물질로 한 태양열 물펌프 연구에서 에너지변환실험, 작동사이클의 열역학적인 해석, 장치의 설계를 수행한 바 있다. 본 연구에서는 펜탄을 작동물질로 한 태양열 물펌프를 실현하기 위하여 기존의 설계를 바탕으로 실험장치를 제작, 실험, 분석하였다. (중략)

  • PDF

High Altitude Simulating Test Facility Design Using Vacuum Pump System (진공펌프 시스템을 이용한 고도모의 시험장치 설계)

  • Hong, Yun Ky;Lee, Jung Min;Na, Jae Jung;Hyun, Dong Ki;Kim, Kyeong Su;Park, Sang Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1160-1164
    • /
    • 2017
  • In this research, a high altitude simulating test facility is designed using vacuum pump system composed of roots pumps and screw pumps. Air flow rate and chamber pressure are 1 kg/s and 2500 Pa, respectively. To design the test facility, experimental tests using certain pump combinations are performed for air injection of the order of hundreds of g/s. From the tests, it is found that 11 roots pumps and 33 screw pumps are required for the considered test facility. Test results are compared with theoretically estimated values. However, intake capacity theoretically estimated is found to be 20 percent larger than test results. This is thought because of higher pressure difference of roots pump for test conditions. Therefore, if more screw pumps are added for the considered pump system, it would be possible to lower the vacuum level of test chamber.

  • PDF

Control Effect of Isolator on the Pump Induced Vibration in Office Building (사무실 건물에서의 펌프진동에 따른 방진장치의 제어효과)

  • 노병철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • 펌프는 다르 진동 유발원들과는 달리 일정한 주파수 및 크기를 갖는 진동을 일으키므로 스프링이나 댐퍼와 같은 간단한 방진기기를 이용하여 진동을 제어할 수 있다 현재 국내에서는 대부분의 펌프에 이러한 방진장치를 설치하는 것이 일반화되어있다 그러나 펌프의 용량 및 중량 주변 구조물의 형태 및 크기 등에 따라서 방진기구의 채택이 불필요한 경우도 있으므로 설비 진동기초에 대한 획일적인 설계와 시공개념은 불필요한 인적, 시간적 및 경제적인 낭비를 초래할 수 있다. 따라서 본 연구에서는 사무용 건무에 사용되는 각종 펌프류에 대하여 가진특성과 구조물의 진동가속도응답을 측정하는 진동실험 및 이론적 해석을 실시하고 본래 계와 수정된 계의 진동을 답과 허용진동수준을 비교.분석함으로서 방진장치의 설치가 불필요한 펌프용량을 제시하였다.

  • PDF

KS 규격 안에 따른 터보분자펌프의 성능시험

  • 박미영;인상렬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.46-46
    • /
    • 1999
  • 터보분자펌프(turbomolecular pump, TMP)는 각종 연구장비, 반도체 제조장치, 가속기, 핵융합 실험 장치 등 여러 분야에서 가장 널리 쓰이는 고진공 펌프로서 자리잡고 있다. 이런 TMP의 광범위한 사용에도 불구하고 성능평가에 관한 통일된 규격이 마련되어 있지 않다. 국제 규격협회(ISO)의 터보분자펌프 성능평가방법 시안을 토대로 제정중인 KS 규격은 아직 실험적인 근거를 자체적으로 가지고 있지 못하므로 앞으로 각 항목들에 대한 많은 실험이 수행되어야 한다. TMP의 성능을 나타내 주는 항목들 중 배기속도(pumping speed)와 압축비(compression ratio)는 가장 중요한 것들로서 다른 고진공 펌프 및 TMP 상호간의 성능을 비교할 수 있는 기본 항목이라 할 수 있다. 본 실험에서는 종래의 단순 TMP와 큰 기체유량에서도 안정된 배기속도를 유지하는 복합터보분자펌프(compound molecular pump, CMP)의 배기속도와 압축비 및 임계배압(critical backing pressure)을 KS 규격안대로 시험 평가하여 안의 평가방법과 기준의 타당성을 검토하고, 두 가지 다른 방식의 펌프에 적용할 수 있는지를 검토하였다. TMP 및 CMP 흡기구에 표준용기를 부착하고 수소 및 질소 기체를 사용하여 흡기구 압력을 변화시키면서 배기속도 및 압축비를 측정하고 배기구 압력을 변호시키면서 최대압축비 및 임계배압을 측정하였다. 흡기구의 압력측정에는 인출형 전리진공계(EG)를 사용하였고, 배기구의 압력측정은 전기용량의 격막진공계(CDG)와 피라니 진공계로 측정하였다. 진공계는 모두 회전식 점성진공계(SRG)로 교정한 후 사용하였다.

  • PDF

Analysis of Flow Characteristics in Pump Sump by Floor Cone Anti-Vortex Device Installation (원뿔 형태의 와류발생저감장치 설치로 인한 펌프 흡수조 내 흐름특성 변화 분석)

  • Byeon, Hyunhyuk;Kim, Heejung;Kim, Seojun;Yoon, Byumgman
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.73-73
    • /
    • 2017
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설 중 빗물펌프장은 흡수조로 우수를 유도한 후 펌프를 이용하여 하천으로 배수하고 있다. 우수를 원활히 하천으로 배수하기 위해서는 흡수조 내 흐름이 안정적으로 형성되어야 한다. 하지만 갑작스런 폭우 등으로 인하여 우수가 짧은 시간에 집중될 경우 흡수조 내에서 빠른 유속과 불규칙한 흐름이 발생하여 와류가 생성된다. 이러한 와류는 펌프 입구로 공기를 유입시켜 효율 저하의 원인이 되며, 공동현상을 발생시켜 펌프의 손상을 초래하기도 한다. 따라서 와류발생 저감장치(Anti-Vortex Device)를 설치하여 와류의 생성을 억제하고자 하는 연구들이 수행되었으며, 그 결과 다양한 형태의 와류발생 저감장치가 소개되었다. 하지만 와류발생 저감장치의 명확한 설계기준이 제시되어 있지 않으며, 와류발생 저감장치를 설치하였을 때 효율이 얼마만큼 증가하는가에 대한 실험적인 자료가 제시되어 있지 않다. 따라서 본 연구에서는 원뿔 형태의 와류발생 저감장치 설치 전 후의 흐름특성을 분석하여 원뿔형태의 와류발생 저감장치가 흐름안정에 얼마나 효과가 있는지를 확인하기 위하여 PIV(Particle Image Velocimetry) 기법을 이용한 유속분포와 와도를 분석하여 흐름 안정 효과를 정량적으로 검토하였다. 그 결과 와류 발생을 저감할 수 있었으며, 정량적으로 와도가 감소하여 펌프 흡입량이 증가됨을 확인하였다. 향후 추가적으로 다양한 형태의 와류발생 저감장치에 대한 효과를 검토한다면 최적의 펌프 흡수조 설계에 도움이 될 것으로 기대한다.

  • PDF

Experimental equipment for high efficiency heat pump development by CFD (CFD를 통한 고효율 히트펌프 개발을 위한 실험장치)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1402-1408
    • /
    • 2020
  • In order to save energy, a lot of research has been conducted to develop a high-efficiency heat pump. Research to reduce or eliminate the occurrence of frost in the outdoor unit coil is also being conducted at the same time. A constant temperature chamber was constructed that allows experimentation under the same conditions as in the natural state so that frost does not occur in the outdoor unit of the heat pump regardless of the season. In order to verify the validity of the experimental apparatus, a simulation was conducted by dividing the straight length of the duct in front of the outdoor unit in the constant temperature chamber, which is the experimental apparatus, into three conditions. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Dynamic Characteristics Prediction of Liquid Rocket Engine for the Transient Sequence Part-II : Propellent Feeding System Modelling and Validation (액체로켓엔진 천이 동특성 예측 Part-II : 추진제 공급 시스템 모델링 및 검증)

  • Ko, Tae-Ho;Jeong, Yu-Shin;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.181-189
    • /
    • 2010
  • 개방형 액체로켓엔진 시스템에 대한 동특성 예측 프로그램을 작성하였다. 이 프로그램을 통해 얻은 펌프 시동 시 시간에 따른 압력 및 유량 변화 결과를 수류실험장치를 구축하여 실험적으로 검증하였다. 수류실험장치는 실제 액체로켓엔진 추진제 공급 계통에서 구성품의 형태와 배치위치, 가스발생기와 주연소실로 분기되는 유량비를 기준으로 모사되었다. 측정 시 관로가 채워진 상태에서 펌프를 시동하였으며 펌프는 전동기로 구동된다. 동특성 예측 프로그램의 작성을 위해 구성품별 동특성 모델링을 수행하고 엔진 시스템을 기준으로 각 모델링을 순차적으로 통합하였다. 구성품의 동특성 파라미터를 측정 반영하였고 압력 밸런싱을 통해 수렴 조건이 결정된다. 수렴된 밀도와 유량을 가지고 다음 시간에서의 초기 입력 값으로 대체하여 계산을 수행하였다. 천이 작동 상태에서 엔진 시스템 내의 물리량 변화를 전산 예측과 더불어 실험적으로 측정하고 비교하였다.

  • PDF

Development of solar powered water pump(II) -Equipment design and water pumping experiments- (태양열을 동력원으로 한 물펌프 연구개발(II) -장치설계와 양수실험-)

  • 김영복;이양근;이승규;김성태;나우정;정병섭
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.267-272
    • /
    • 2002
  • 자연에너지이면서 자원이 풍부한 태양에너지를 동력으로 변환하여 얻어진 기계적인 일을 이용하여 물 펌프를 구동하면 이 장치는 물이 매우 필요한 때인 여름철의 경우 그 동력원인 태양열이 강하기 때문에 아주 이상적인 장치라고 할 수 있다. 이 장치는 특히, 전기가 잘 공급되지 않는 농촌의 경우 아주 유용하게 사용될 수가 있을 것이다. (중략)

  • PDF

크라이오 펌프 종합특성평가 시스템 기술개발

  • In, Sang-Ryeol;Jeong, Seung-Ho;Hwang, Pil-Seo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.93-93
    • /
    • 2011
  • 고진공 펌프 국산화의 일환으로 터보분자 펌프와 크라이오 펌프 개발이 진행 중이다. 크라이오 펌프 개발은 기계연구원, 우성진공(주), 국민대학교가 연합해서 수행하고 있다. 올해 9월말에 끝나는 1단계 마지막 3차 년도에는 두 고진공 펌프 모두 시제품을 완성하고 성능을 입증해야 한다. 이를 위해 고진공 펌프 개발과 별도로 진공 펌프 종합특성평가 시스템 개발도 표준과학연구원 주도로 진행되고 있는데 크라이오 펌프 평가 시스템은 원자력연구원이 담당하고 있다. 완성된 크라이오 펌프 성능평가 장치는 상온 기준 5${\times}$10-11 mbar의 기저압력을 보이고 있어서 초고진공 영역에서 크라이오 펌프 운전성능을 평가할 수 있는 준비를 마쳤다. 현재 크라이오 펌프 냉동기는 전반적으로 목표 설계치에 근접한 냉각성능을 나타내고 있는데 예를 들면 2차 냉각단 냉각능력이 10 K, 10 W로 대형 크라이오 펌프를 제작하기에도 충분하다. 활성탄 어레이도 여러 모델들을 자작하여 배기성능을 시험해 보았으므로, 최종적으로 3,600 L/s 급에 적합한 어레이를 만들고 이를 개발된 냉동기에 얹고 열차폐와 몸통을 씌워 펌프로서의 운전성능을 평가하는 일이 남아있다. 시제품은 상용품과 달리 기기가 차지하는 공간이 크고 부대설비가 복잡해서 운전성능 평가 장치에 부착해서 실험하기 어려울 수도 있으므로 기계연구원 현장에서 진공 게이지와 기체도입구만 부착한 마구리 플랜지를 펌프 흡기구 위에 달고 간이로 배기속도를 측정하는 것도 고려하고 있다. 이 경우는 표준용기를 사용할 때보다 배기속도가 과대평가되므로 이를 보정해 주는 방안을 마련해 놓아야 한다.

  • PDF

Rainfall Distribution Characteristics of Artificial Rainfall System for Steep-Slope Collapse Model Experiment (급경사지 붕괴 모의실험을 위한 인공강우장치의 강우분포특성)

  • Jeong, Hyang-Seon;Kang, Hyo-Sub;Suk, Jae-Wook;Kim, Ho-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.828-835
    • /
    • 2019
  • An artificial rainfall system is used widely as a research tool for generating model experiment data. Artificial rainfall devices have been used in many studies, but studies of the rainfall distribution are not considered as important issues. To simulate various rainfall characteristics, it should be possible to simulate from low to high intensity, and the homogeneity of the rainfall distribution should be ensured. In this study, the maximum rainfall intensity was set to 130mm/hr and controlled by 10mm/hr. In addition, the aim was to secure a uniform coefficient value of 80% or more. To this end, rainfall tests were performed according to the nozzle type, diameter, position, and pump pressure. The rainfall test showed that the circular nozzle was suitable, and the nozzle size was 1.9mm and 1.4mm. The optimal pump pressure was found to be 3~6kg/㎠. The rainfall intensity tended to increase linearly with increasing pump pressure. Based on the rainfall test results, a rainfall control manual was produced with variables, such as pump pressure, nozzle type, and number of nozzles. As a result of rainfall verification, rainfall intensity showed a 3.1% error with a uniformity coefficient of 86%.