• Title/Summary/Keyword: 펌프시스템 설계

Search Result 392, Processing Time 0.031 seconds

Construction and Validation Test of Turbopump Real-propellant Test Facility (터보펌프 실매질 시험설비 구축 및 인증시험)

  • Kim, Jin-Sun;Han, Yeoung-Min;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.85-93
    • /
    • 2015
  • Liquid rocket engines of KSLV-II employ a turbopump feed system for propellants. A turbopump real-propellant test facility based on liquid oxygen and kerosene has been constructed for the experimental verification of the turbopump performance using the real media of propellants(i.e., LOX/Kerosene). The verification tests of sub-systems were performed such as LOX/kerosene feed system and alcohol burner system. Finally, the performance of the whole system was executed and verified through a sets of validation tests with the development model of the KSLV-II turbopumps. It has been confirmed that the test facility satisfies the operating conditions and time of the turbopump at the design and off-design performance test using real-propellant.

Optimum Pumping Rates of Ground-Water Heat Pump System Using Groundwater or Bank Infilterated Water (강변여과수와 천부 지하수를 이용하는 지하수 열펌프시스템의 적정유량)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Jeon, Jae-Soo;Kim, Hyong-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.833-841
    • /
    • 2007
  • The groundwater heat pump system(GWHP) is one of the most efficient ground source heat pump system(GSHP) which uses low grade and shallow geothermal energy for cooling and heating purpose. The GWHP system shall be designed properly based on peak block load performance and optimum pumping rate of groundwater comparable to ground coupled heat pump system(GCHP). The optimum pumping rate depends on groundwater temperature at a specific site, size of plate heat exchanger, and total head loss occurred by whole system comprising pumps and pipings. The required optimum flow rates of the system per RT are ranged from 3.8 to 9.8lpm being less than the typical building loop flow of 9.5 to 11.4lpm.

Design of Remote & Wireless Control System for Submarine using RF (RF를 이용한 잠수함 무선 원격시스템 제어 설계)

  • Kim, Young-Keun;Ryu, Kwang-Ryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.192-195
    • /
    • 2007
  • 본 논문에서는 RF 모듈을 탐재한 Atmega 시스템 설계를 통한 잠수함 원격 제어 시스템을 구현한다. 본 연구에서 제작한 RC 잠수함은 실제 잠수함의 원리와 비슷하게 잠항을 할 때는 소형펌프로 밸러스트탱크에 물을 채우고, 잠수를 할 때 수직타와 추진력을 이용하여 잠항을 한다. 이와 반대로 부상은 소형펌프로 밸러스트탱크 안에 물을 배수하여 WTC(방수실린더)안의 기압과 수직타와 추진력을 이용하여 부상을 한다. RC 잠수함은 크게 외부와 내부 그리고 방수를 하기 위한 WTC(방수 실린더)로 나누어진다. 송신 부는 RF 모듈, MCU(Atmega128), 키패드, 캐릭터LCD로 구성되며 수신부는 MCU(Atmega128), RF 모듈, 제어장치들로 구성한다. 제어장치에는 모형 잠수함은 추진력을 위하여 DC 모터에 스크류(프로펠러)를 장착하고, 방향전환 및 잠항과 부상을 위하여 RC 서보 모터를 사용하고 잠항과 부상을 위하여 펌프를 사용한다. WTC는 방수실린더로서 아크릴파이프를 이용하여 제작하고 방수를 위하여 아크릴파이프를 이용 여기에 MCU와 제어 장치들을 넣어 밀봉시켜 방수를 하여 완성한다.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating (화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정)

  • Ryou, Young Sun;Kang, Youn Ku;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • This study was carried out in order to determine the optimum length of a roll type PE pipe heat exchanger employed in the water-to-water heat pump system using the waste heat of the heated effluent flowed out from thermal power generation plants as a heat source. And the heat pump system of 30 RT for an experimental test was designed and manufactured. And also PE pipes were employed to recover the waste heat from the heated effluent. The inside diameter of PE pipe heat exchanger was 20 mm, the thickness was 2 mm and the diameter of a roll was 1,000 mm. And from the results of this study, we found that the optimum length of PE pipe heat exchanger was 75 m per the heat pump capacity of 1.0 RT (3.51 kW) and then the heating COP of heat pump system was 3.8.

초고진공펌프를 위한 구동장치 개발

  • O, Hyeong-Rok;No, Gyeong-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.21-21
    • /
    • 2010
  • 본 개발에서는 초고속 복합 분자펌프 구동을 위한 디지털 구동장치를 설계하였다. BLDC구동을 위한 디지털 제어 시스템의 핵심제어 보드 설계 및 모듈 설계를 하여 보드제작 및 기본성능평가를 하고 고속 회전 실험을 하였다. AMB의 구동 특성을 파악하였으며 AMB 구동을 위한 와전류식 변위 센서의 구동 특성을 파악하였다. 와전류식 변위 센서의 거리측정 방법을 구현하였으며 AMB와 와전류식 변위센서 구동부를 설계하였다.

  • PDF

Performance Analysis of Freezing Desalination System using Seawater Heat Pump (해수 히트펌프를 이용한 냉동법 담수화시스템 개념설계)

  • Lee, Ho-Saeng;Lee, Seung-Won;Yoon, Jung-In;Kim, Hyeon-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.373-378
    • /
    • 2011
  • The freeze desalination cycle with seawater heat pump system is simulated and designed for the basic data for the design of freeze desalination system. The basic model of seawater heat pump system is refrigeration cycle and indirect freeze desalination method is used for seawater desalination. The cycle performance of seawater heat pump such as COP, compressor work, condensing capacity was analyzed and the desalination performance such as fresh water productivity and energy per unit fresh water productivity was compared with respect to the seawater temperature of condenser inlet and ice ratio in the evaporator. The compressor work and condensing capacity decreased with respect to the decrease of seawater inlet temperature. The energy per unit fresh water productivity in case of $8^{\circ}C$ seawater inlet temperature showed 28.9% lower than that of $20^{\circ}C$.

Minimization of Pump Running Cost in the Large-scale Water Supply System (광역상수도 계통의 Pump 운전비용 최소화)

  • Lee, Gwang-Man;Kang, Shin-Wook;Kim, Soo-Myung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.276-281
    • /
    • 2009
  • 장거리 용수공급 시스템에서 전력비용은 전체 운영비용의 큰 부분을 차지한다. 본 연구는 시간단위의 펌프와 배수지 시스템의 최적 운영계획을 수립하기 위해 동적계획기법에 기초한 방법론을 제시하고 있다. 해석방법은 가용 가능한 펌프의 효율적 운전과 전력요금체계, 시간대별 용수수요추이 그리고 배수지 특성과 송수관로의 제약조건 등을 고려하였다. 이를 위해 적용 가능한 시스템 운영목적과 제약조건이 제시되었고 개발된 방법은 수도권 광역상수도 양주계통의 2개 가압장과 5개 배수지를 대상으로 적용되었으며, 적용결과는 상당한 수준의 펌프운전비용을 절감할 수 있는 것으로 나타났다. 이와 같은 방법은 생애주기 비용 최소화 측면에서 실제 용수공급 시설 운영과 대규모 용수공급 체계의 설계 등에 적용이 가능하다.

  • PDF

Multi type heat pump system computer simulation and experimental verification (멀티형 히트펌프 시스템 컴퓨터 시뮬레이션과 실험적 검증)

  • 한도영;정민영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.12-19
    • /
    • 2000
  • The multi type heat pump system may provide more energy savings and better environmental conditions than the single type heat pump system may do. In order to design a multi type heat pump system, it may be recommended to develop the system simulation program, which can predict the characteristics of the system such as unit capacities, power consumptions, and system COP's. In this study, the steady state simulation program of the multi type heat pump system was developed. The results from the simulation program were compared with those from the experimental tests which were performed in the environmental chamber, Cooling tests show 3.11% and 0.94% of error in capacity and COP, and heating tests show 3.30% and 1.90% of error in capacity and COP, respectively. Therefore, the steady state simulation program developed for this study can effectively be used for the design and the performance prediction of the multi type heat pump system.

  • PDF

80K 200W급 단단 G-M 극저온 냉동기 개발에 따른 성능평가(2)

  • Lee, Dong-Ju;Han, Myeong-Hui;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.93.1-93.1
    • /
    • 2015
  • 근래 디스플레이 분야에서 OLED가 시장을 주도하면서 이 공정에 가장 적합한 진공펌프로 크라이오 펌프가 주목을 받고 있다. 화소 형성 공정에 사용되는 유기물이 수분에 취약하기 때문인데, 크라이오 펌프가운데서 특별히 수분만 집중적으로 배기할 수 있는 워터펌프(CWP or cold trap)가 각광받고 있다. 이에 HM GVT는 중소기업청 중소기업개발지원사업의 일환으로 진행된 2014년도 구매조건부 신제품 개발사업에 선정되어 '극저온 G-M냉동기를 이용한 대용량 Cold Trap개발' 과제를 수행하면서 32인치 급으로 수분에 대해서 30,000 [L/s] 이상의 배기속도를 가지는 대형 CWP를 개발하고 있다(수요처: (주)아바코). 통상적으로 흡기구가 30인치라면 수분 배기속도는 대략 65,000 L/s에 이르고 200 W 냉각능력이면 최대 수분 분압 0.008 mbar에서 작동시킬 수 있다. 따라서 1차년도의 목표는 큰 배기용량과 대형 사이즈의 CWP를 개발하기 위해 80 K에서 200 W 이상의 냉동능력을 보유한 단단 G-M 극저온냉동기를 선행 개발하는 것이다. 이에 현재 최대 냉동능력 80 K에 130 W의 냉동능력을 가지는 HPS055모델을 이용하여 다양한 예비시험들을 수행하여 최적의 설계인자들을 도출하였고 이를 근거로 80 K에서 200 W 이상의 냉동능력을 가지는 HPS80200모델을 설계 및 제작, 성능시험을 수행하였다. 이에 국내 최초로 80 K에서 200 W의 냉동능력을 가지는 단단 G-M냉동기를 개발하였고 설계 및 제작에 대한 원천기술을 확보할 수 있었다.

  • PDF