• Title/Summary/Keyword: 펌프손실

Search Result 143, Processing Time 0.028 seconds

Design and Performance Analysis of a Fuel Transfer Jet Pump in the Smart UAV Fuel Supply System (스마트무인기연료공급시스템 연료이송 제트펌프의 설계 및 성능해석에 관한 연구)

  • Park, Sul-Hye;Lee, Yoon-Kwon;Lee, Jee-Keun;Lee, Chang-Ho;Lee, Soo-Chul;Choi, Hee-Joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.11
    • /
    • pp.1013-1021
    • /
    • 2007
  • Design and performance analysis of the jet pump to transfer fuel between tanks in the smart UAV fuel supply system were carried out through one dimensional flow analysis and the flow analysis using a commercial CFD code. From the analysis results, it was proved that the jet pump was designed with the flow ratio of 2.23 that is the fundamental requirement of the jet pump design. The comparison results showed that the primary nozzle pressure is higher in the CFD analysis than in one dimensional flow analysis, mainly due to the underestimated loss coefficient of the primary nozzles. Consequently, the loss coefficients of the jet pump components should be determined more precisely for the design of the jet pumps with high performance.

Mass flow rate of Knudsen pump According to Membrane Type for Micro Propulsion Applications (초소형 추진장치에 적용을 위한 누센펌프의 멤브레인 종류에 따른 질유량 특성)

  • Kim, Hye-Hwan;Huh, Hwan-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.36-40
    • /
    • 2008
  • Minimization of nozzle induces many flow losses in micro-propulsion system. In this study, we studied about thermal transpiration based new conceptual micro propulsion system to overcome these losses. Thermal transpiration device(Knudsen pump) having no moving parts can self-pump the gaseous propellant by temperature gradient only (cold to hot). We designed, fabricated the knudsen pump and analyzed pressure gradient efficiency of membrane according to Knudsen number under vacuum condition. In this paper, we compared mass flow rate of Knudsen pump by using different membrane type ; Polyimide and Hangi, Korean traditional paper.

  • PDF

전기 . 유압 펌프 시스템의 설계 및 제어에 관한 연구

  • 강종우;황성호;박성환;하석홍;이진걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.181-184
    • /
    • 1993
  • 일반적으로유압 장치를 사용하여 힘, 속도, 그리고 위치 등을 제어하는 경우 그 제어계의 설계, 제어방식의 선택에있어서는 최종 목표치의 정도, 응답성 등의 제어 성능을 고려함과 동시에 공업적으로는 가격, 동력효율 등이 중요한 설계인자로서 고려 되어 져야한다. 제어 방식응 벨브 제어와 펌프 제어 방식으로 크게 나뉘어 질 수 있으나, 벨브 제어방식에 있어서는 유압 서보벨브를 사용하여 출력 기구를 고정도로 직접 구도하는 것이 많으나 동력손실이 큰 편이며, 효율을 개선하기 위하여 압력 보상형 비례 전자 제어 벨브를 이용하는 것도 있으나, 소출력용으로서만 이용가능할 뿐이다. 이에 비하여 가변 용량형 펌프를 이용한 제어방식은 정도, 응답성은 다소 뒤떨어 지지만 효율이 양호하고 대출력 기구에 적용 가능하다는 점에서최근 주목의 대상으로되고 있다. 본 연구에서는 에너지의 효율적인사용이 가능한 전기. 유압 펌프 시스템을 설계하기위하여 먼저 각 신호전달 요소에 대한 동특성 및 정특성 실험을 행하여 시스템의 근사적인 모델링을 행하고 사판의 경사각을 제어함으로써 유압모터의 속도를 제어하는 시스템을 설계하여그 성능을 고찰하고자 한다.

엔진 윤활시스템 유로망 해석

  • 전상명
    • Journal of the KSME
    • /
    • v.32 no.11
    • /
    • pp.947-954
    • /
    • 1992
  • 이 글에서는 엔진 윤활 시스템해석 프로그램의 구성 요인 및 프로우차트를 열거했으며 이렇게 만들어진 프로그램을 이용하여 엔진의 개선 및 신엔진 개발 시에 매개변수를 변화시켜가며 오일 유로의 설계와 요구되는 오일량을 결정하여 최적의 윤활시스템을 설계할 수 있다고 본다. 참고로 밸브시스템의 정상적인 작동을 유지하는 상태에서 요구되는 토출 유압과 유량이 줄어들면 오일 펌프의 용량을 줄일 수 있고 그로 인해 오일 펌프 구동손실도 줄일 수 있다. 또한 최적 유량이 공급될 때 엔진 구동손실을 최소화할 수 있다. 더나아가 본 해석으로 얻은 최적화된 유량이 만족 된 이상적인 윤활 부위의 치수가 결정된 상태에서 운동부의 마찰을 최소화하는 엔진 마찰의 수치해석적 모델을 개발하는 것도 흥미있는 과제이다. 또한 간단한 테스트 리그 제작에 의한 각 윤활 부품에서의 압력-유량 관계 실험식의 정확도를 높이는 것도 앞으로의 과제이다.

  • PDF

Fabrication and Output Characteristics of an (18+1)×1 Polarization-maintaining Pump and Signal Combiner for a High-power Fiber Laser (고출력 광섬유 레이저용 (18+1)×1 편광유지 펌프 및 신호광 결합기 제작 및 출력 특성)

  • Lee, Sung Hun;Kim, Ki Hyuck;Yang, Hwan Seok;Cho, Seung Yong;Kim, Seon Ju;Park, Min Kyu;Lee, Jung Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2019
  • In this paper a pump combiner, a key component of a high-power fiber laser, was fabricated, and its output characteristics measured using a high-power performance measuring instrument. The $(18+1){\times}1$ pump combiner consists of an optical-fiber bundle of one signal fiber and 18 pump fibers, an output optical fiber, and housing. The signal and output fibers were fabricated using polarization-maintaining optical fiber. By measuring the loss of signal light along the tapering length of the optical-fiber bundle, the tapering length was optimized to 18 mm. Signal-light insertion loss, pump-light transmittance, and polarization extinction ratio of the fabricated $(18+1){\times}1$ pump combiner were measured as 6.5%, 98.07%, and 18.0 dB respectively. The temperature distribution of the pump combiner, at a high power of 2 kW using 18 pump laser diodes, was measured and analyzed using a thermal-imaging camera.

Hydraulic Tests of Lox Pump for 75-ton class Liquid Rocket Engines (75톤급 로켓엔진용 산화제펌프의 수력성능시험)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.77-80
    • /
    • 2010
  • A series of hydraulic tests of a Lox pump are performed using water at a room temperature. According to the test results, the Lox pump satisfies its design requirement but both the head and the efficiency do not fully follow the conventional similarity rule. The deviation of the head from the rule is assumed to be due to the increased volute loss at high rotational speed. Furthermore, it is found that when the pump rotates with the flow ratio less then the design requirement the leakage flowrate seems to be increased.

  • PDF

Performance Characteristics of a Variable Displacement Engine at Part-Load and Idle (부분부하와 무부하에서의 가변 배기량기관의 성능특성)

  • 한성빈;이성열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.232-239
    • /
    • 1994
  • This paper presents an effective way of improving fuel consumption for a variable displacement engine. The improvement of fuel consumption can be accomplished by means of deactivating inlet and exhaust valves, reducing the number of effective cylinders of a four-cylinder gasoline engine that is mounted on a domestic compact automobile.

Performance of long-haul optical fiber commumication system using optical amplifiers with post amplifier loss (후치 증폭기 손실을 갖는 광섬유 증폭기를 사용한 장거리 광통신 시스템의 성능형가)

  • 이무도;이호준;이화용
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.326-332
    • /
    • 1994
  • Performance of soliton based long-haul optical communication system with in-line optical amplifier repeaters are evaluated numerically. To reduce the optical amplifier noise, the amplifier gain is increased and the post amplifier loss is included. By theoretical calculation with 1480 nm co propagating pump, 7 dB amplifier gain and operating the amplifier 1 dB in compression, the spontaneous emission factor can be reduced from 2.37 to 1.45 by increasing the pump power from 3.71 to 11.53 mW and increasing the post amplifier loss from 0 to 10 dB. Then, power penalty can be reduced from 4.09 to 1.20 dB for 8,000'km transmission and the maximum transmission distance is 14,890 km. ,890 km.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

Development of an Automatic Refrigerant Charging Device for Refrigeration Applications (냉동기용 자동 냉매 충전장치 개발)

  • 김성수;윤희정;홍희기;강용태
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.253-258
    • /
    • 2003
  • Manual type manifold gauge has been used for charging the refrigerant in the refrigeration systems. In this case, the refrigerant is released to the ambient during the hose-switching period. :he objectives of this study are to develop a novel automatic refrigerant charging system, and to quantify the effect of the automatic systems on the reduction of the non-condensable gas and the contamination of the compressor oil. The automatic charging system makes the pressure test, vacuum test, and refrigerant charging work very simple and easy because the charging hose does not have to be switched many times. It is found that the amount of water in the SiO$_2$and the compressor oil reduces to l/4 times of that for the manual type manifold gauge and the refrigerant is not released to the ambient at all when the automatic charging system is adopted.