• Title/Summary/Keyword: 펌프동력

Search Result 158, Processing Time 0.027 seconds

Performance Characteristics of R134a Supercritical Heat Pump (R134a 냉매용 초임계 히트펌프의 성능 특성)

  • Choi, In-Soo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.

Performance Analysis of Freezing Desalination System using Seawater Heat Pump (해수 히트펌프를 이용한 냉동법 담수화시스템 개념설계)

  • Lee, Ho-Saeng;Lee, Seung-Won;Yoon, Jung-In;Kim, Hyeon-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.373-378
    • /
    • 2011
  • The freeze desalination cycle with seawater heat pump system is simulated and designed for the basic data for the design of freeze desalination system. The basic model of seawater heat pump system is refrigeration cycle and indirect freeze desalination method is used for seawater desalination. The cycle performance of seawater heat pump such as COP, compressor work, condensing capacity was analyzed and the desalination performance such as fresh water productivity and energy per unit fresh water productivity was compared with respect to the seawater temperature of condenser inlet and ice ratio in the evaporator. The compressor work and condensing capacity decreased with respect to the decrease of seawater inlet temperature. The energy per unit fresh water productivity in case of $8^{\circ}C$ seawater inlet temperature showed 28.9% lower than that of $20^{\circ}C$.

Heat Transfer and Pump Consumption Power of Indirect Refrigeration System Using CO2 as a Secondary Refrigerant (2차 냉매로서 CO2를 사용하는 간접 냉동시스템의 열전달과 펌프 소비동력)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Yi, Wen-Bin
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.25-30
    • /
    • 2014
  • In this paper, the heat transfer coefficient and pump consumption power of indirect refrigeration system using $CO_2$ as a secondary refrigerant were investigated experimentally. First, from the comparison of pump consumption powers of existing brines(EG, PG, EA etc.) and $CO_2$ as secondary refrigerants at the same experimental conditions, PG and $CO_2$ show the highest and lowest power, respectively. Second, the heat transfer coefficient of $CaCl_2$ is the highest, but PG is the lowest among other secondary refrigerants. From the above results, it is confirmed that $CO_2$ as the secondary refrigerant has excellent characteristics when comparing to existing brines. Thus, it is concluded that $CO_2$ is applicable as the secondary refrigerant of indirect refrigeration system.

지역냉난방 시스템

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.40
    • /
    • pp.84-95
    • /
    • 1993
  • 지역난방은 한 곳에 집중된 대규모 열원시설에서 경제적으로 생산된 열을 일정한 지역내 아파트, 빌딩, 공공 시설 등에 난방 및 냉방용으로 공급하는 도시 기반시설이다. 또한 지역난방은 개별난방이나 중앙난방의 간헐 난방방식과는 달리 24 시간 연속난방을 하므로써 건강하고 쾌적한 실내온도를 유지시켜 주며, 노후된 보일러 교체비 및 유지 보수가 들지 않고, 난방순환펌프 등 각종 부대시설의 축소로 동력비를 절감할 수 있으며 기존 보일러실을 주민복지 공간으로 활용할 수 있고, 연료탱크와 보조난방기구 등이 필요 없어 재해 발생의 우려가 없다. 본지에서는 한국지역난방공사에서 제공한 자료와 월간 설비기술에 게재된 내용을 요약 정리하여 게재한다.

  • PDF

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

Circuit Capacity of Water Cooling on Domestic Small Diesel Engine (소형(小型)디젤 기관(機關)의 냉각수(冷却水) 순환량(循環量)에 대(對)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.91-96
    • /
    • 1992
  • Diesel engine being used on power tiller has over heating problem while running at the rated power range, The reason for overheating the engine is mainly owing to so small capacity of cooling system. This study was conducted to determine relatively optimum capacity of cooling system for the diesel engine. The results obtained are summarized as follows. 1. The capacity of cooling system for the diesel engine being used in the rural area was not sufficient to cool the engine at the rated power. 2. It is desirable that the cooling water flow rate was $12{\ell}/min$ if we used supplementary pump for increasing the cooling efficiency. 3. As cooling water was circuited $12{\ell}/min$, highest temperature of cooling water was $91^{\circ}C$. This value is within $88^{\circ}C{\pm}5^{\circ}C$ of SAE Standard criterion.

  • PDF

Demonstration project on utilization of solar thermal energy on Hybrid Cooling and Heating system (태양열 이용 Hybrid냉난방시스템 실증연구)

  • Mun, Jong-Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.363-372
    • /
    • 2005
  • 최근 고유가상황 및 에너지소비가 증대되는 사회적 분위기와 환경적 변화에 힘입어 대체에너지기술개발에 대한 절실한 대책마련이 중요시 되고있다. 기후변화협약의 발효로 환경에너지에 대한 새로운 인식의 필요로 에너지체제의 변환이 촉구되어지고 있으며 이에 따른 환경친화적 에너지자원을 이용한 신 재생에너지개발에 대한 연구개발기술이 관심을 받고 있다. 현재 사용중인 화석연료는 환경오염 및 지구의 온난화 현상 등 심각한 공해문제를 야기시키고 있는 반면에 태양에너지와 같은 청정에너지의 개발은 환경오염방지와 친환경에너지자원의 활용이라는 점에서 관심이 대상이 되고 있고 특히, 우리나라의 경우 에너지수입 의존율이 97%로 높은 상황에서 국가에너지대책을 수립하고 해외수입에너지 의존율을 최소화시키기 위하여 가히 필수적인 상황이다. 따라서, 본 실증연구사업(태양열 이용 Hybrid냉난방시스템 실증연구)은 태양열 집열기에서 생산된 저온의 $20\sim30^{\circ}C$의 승온된 양질의 열원을 히트펌프 증발기 열원으로 이용 히트펌프의 압축동력이 상대적으로 작아져 기존 히트펌프 시스템에서의 성적계수(COP)를 높여 주는 효과를 기대할 수 있고, 특히 하절기 복사량이 많은 시기에는 $50\sim60^{\circ}C$ 정도로 승온되어진 중 고온수를 직접 온수탱크로 이동시켜 필요수요처에 공급함으로써 이에 따른 에너지절감효과를 기대할 수 있다. 구축된 태양열 이용 하이브리드(Hybrid)냉난방시스템은 계절별, 설비별 특성을 적절히 활용하여 연평균 집열기 효율은 70%수준으로 유지하면서, 계절별 성적계수는 '4'수준을 목표로 하여 추진되었으며, 그간, 태양열 이용 보급분야의 실용화는 주로 건물의 급탕용 온수생산의 수준에 머물렀으나 이 단계를 극복한 건물의 냉 난방 및 급탕을 위한 태양열 및 공기열원을 활용한 하이브리드(Hybrid)냉난방 시스템 구축하였다. 아울러, 태양열 이용 하이브리드 냉난방 히트펌프 시스템 실증 실험은 유가상승과 신재생에너지에 대한 국가적 분위기 고취로 어느때 보다도 개발기술의 상용화 및 실용화적 측면의 염두와 태양열 이용 Hybrid냉난방 시스템의 효율향상과 저가화를 통해 기술의 경제성과 신뢰성을 확보하여 태양열 이용 시스템의 보급활성화를 목표로 하고 있다.

  • PDF

A study on the comparison of the performance of a heat pump system with air and water heat sources (공기열원 및 수열원을 이용한 열펌프 시스템의 성능특성에 관한 연구)

  • Ko, Won-Bin;Park, Youn-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.563-568
    • /
    • 2016
  • In this study, experiments were conducted to evaluate the performance of a heat pump system. A heat pump system with an air as heat source is adapted as reference. The developed system uses a plate heat exchanger an evaporator to absorb heat from a stack of fuel cell driven electric vehicles. Hence, the system functions as a water source heat pump system. The results indicated that the; power consumption increased with the rotational speed of the compressor. A system performance($COP_h$) of 2.03 at an electronic expansion valve(EEV) openings of 25% and a compressor speed of 1200 rpm was observed in the reference system. However, at the same compressor speed, the $COP_h$ of the water source heat pump system corresponded to 9.42 at an EEV openings of 75%. It was found that the water source heat pump system exhibited the highest performance at a water temperature of $50^{\circ}C$.

Air Similarity Performance Test of Turbopump Turbine (터보펌프용 터빈 공기상사 성능시험)

  • Lim Byeung-Jun;Hong Chang-Uk;Kim Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.39-45
    • /
    • 2006
  • In liquid rocket engine turbopump, it is difficult to evaluate turbine performance for high pressure, high temperature circumstance. Turbine test is often done by using air at similarity condition so that the turbine can be tested at lower risk. This paper describes an air similarity test program of liquid rocket engine turbopump turbine. A test facility has been built to evaluate aerodynamic performance of turbines. The test facility consists of high pressure air supply system, mass flow rate measuring nozzle, test section, hydraulic break, exit orifice for pressure control, instrumentation and control system. This paper also presents how to decide the similarity conditions of the turbine test and describes how to control test conditions. Relative standard deviation of measurement parameter was less than 1% and measured turbine efficiency corresponded with analysis result within 2%.

Sludge Pre-Treatment by Hydrodynamic Cavitation-I: Optimization of Pre-Treatment System (수리동력학적 캐비테이션을 이용한 하수 슬러지의 전처리-I: 전처리 시스템의 최적화)

  • Maeng, Jang-Woo;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1119-1125
    • /
    • 2010
  • Most of the sludge pre-treatment methods to improve the anaerobic digestibility of sludge are not practied in the fields with low economical efficiency. The venturi cavitation system (VCS) adopting hydrodynamic cavitation is simple and requires low energy. This research was conducted to investigate the optimum design and operating conditions of the VCS. The experimental results indicated that the optimum number of venturi in series was three, and the suction mode operation of the pump yielded 1.6 times higher pre-treatment efficiency per unit energy consumption than the discharge mode. The combination of venturies with different throat sizes did not affect the pre-treatment efficiency. Also, the parallel installation of the three in series venture unit yielded 30% higher pre-treatment efficiency per unit energy consumption than the single unit. Under parallel conditions, the solubilization efficiency was 5.6 mg ${\Delta}SCOD/g$ TS/kWh, which is higher than the previously reported value.