• 제목/요약/키워드: 팬소음

검색결과 179건 처리시간 0.026초

축류 팬을 이용한 충돌제트 전자냉각 설계개념에 대한 연구 (Study on the Design Concept of Impinging Jet Electronics Cooling by Using Axial Fan)

  • 이찬;길현권
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.24-30
    • /
    • 2009
  • Flow and noise analyses are conducted for examining a new design concept of impinging jet electronics cooling, and the analysis results are compared with conventional electronics cooling techniques. For the application of impinging jet electronics cooling method, the present study considers the air duct where air is supplied by axial fan and air flow from the duct is impinged vertically onto the electronic component heat source. Applying CFD simulation technique and fan noise model to the present cooling scheme, the cooling performance of the impinging jet as well as the operation condition and the noise characteristics of fan are investigated for various impinging jet nozzle conditions and fan models. Furthermore, the impinging jet electronics cooling analysis results are compared with the conventional parallel-flow cooling scheme to give the design concept and criteria of impinging jet cooling method.

상용차용 전동 쿨링팬 개발에 관한 연구 (An investigation on development of bus electrical cooling fan system)

  • 김주한;정인성;서정무;허남건;정재혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.144.1-144.1
    • /
    • 2010
  • 현재의 세계 자동차 시장은 석유 자원의 고갈과 전자화로 높은 연비의 기술적 성숙을 요구하고 있으며, 이는 미래 자동차 기술의 전동화를 가속시키고 있음에 따라 종래 엔진부하로 사용되는 시스템 및 유압시스템의 전동화 기술추이가 지속적으로 증가하고 있다. 이중 엔진 부하 메커니즘의 하나인 엔진 쿨링 팬 분야는 소비용량이 크고, 고 연비증감 기술증진의 전동화에 따른 차량 성능개선의 효과가 높아 실용 전동화 용의성에 의해 새로운 최우선 차량 전동부하로 나타나고 있다. 특히, 대형 차량(버스, 트럭)의 엔진 Cooling Fan 시스템은 차량 연비저감의 주요원 중에 하나로 대두되고 있으며, 도시 소음의 주된 요인이 되고 있어 전동화 기술개발의 필요성이 매우 높다. 전동 Cooling Fan 시스템은 종래 엔진 구동형 시스템에 비하여 엔진부하를 감소시킬 수 있고, 차량 연비향상 및 유해배출 가스를 저감시킴으로 기술적, 환경적 개발효과가 매우 높다. 본 연구에서는 쿨링팬 고출력 BLDC모터 설계제작에 관한 내용과, 최적 팬 블레이드 설계제작, 마지막으로 개발 전동 쿨링팬 성능평가에 관한 내용이 포함되어 있다.

  • PDF

반응면 기법을 이용한 자동차 엔진 냉각팬의 저소음설계 (Optimization of Automotive Engine-cooling Fan Noise Using Response Surface Method)

  • 이정한;안재권;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.407-412
    • /
    • 2000
  • Response surface method is employed in optimizing the acoustic performance of automotive engine-cooling axial fans. The effects of modifications in blade geometry on noise reduction are investigated. Taking the far-field noise level as the objective, a quadratic response surface is constructed utilizing D-Optimality condition as the candidate-points selection criteria. It is shown that the quadratic model exhibits an excellent fitting capability resulting in the blade design with low far-field noise level.

  • PDF

횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구 (Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan)

  • 박이선;손채훈;이성철;오장근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

능동소음제어를 이용한 효과적인 팬소음의 제어 (Effective Fan Noise Control Using Active Noise Control)

  • 엄승신;신인환;이수갑
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 2호
    • /
    • pp.433-438
    • /
    • 1999
  • 본 논문은 기계장치에서 발생하는 소음 중 불필요한 소음만을 제거하고 실제로 필요한 소음(경고음 작동음 등)의 정보를 가진 소리는 제거하지 않는 소음 제어 방법을 Active Noise Control(ANC)를 이용하여 구현하였다. 소음원으로는 축류팬(Akial Fan)을 사용하였으며 여기서 발생하는 BPF를 효과적으로 제어할 수 있는 Feedback Active Noise Control 방식을 사용하였으며 적응 알고리즘으로 Filtered-X LMS 알고리즘을 사용하였다. 실험은 두 가지 Case(덕트 내 전파 소음, 외부 자유 음장 방사 소음)로 실행되었다. 제거하고자하는 대상은 BPF 소음이며 이 이외의 주파수에는 영향을 주지 않게 하기 위하여 대역필터를 이용하였다. 또한 실제 인간이 느끼는 소음 감소 효과를 알아보기 위해 Loudness로 제어 전후의 결과를 비교하였다. 실험 결과 BPF만 감소시키고 BPF이외의 주파수에는 영향을 주지 않음을 알 수 있었으며 6.7dB의 Loudness level의 감소 효과를 얻어, 제어하고자 하는 주파수만을 제어하였으며 음압뿐 아니라 인간이 느끼는 소음도에서도 효과적으로 감소할 수 있음을 확인할 수 있었다.

  • PDF

한 쌍의 푸쉬-풀 와이어를 이용한 로봇 안구의 팬-틸트 모션 생성 (Pan-tilt Motion Generation of Robot Eye by Using a Pair of Push-pull Wires)

  • 정찬열;오경균;박신석;김승종
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.3-8
    • /
    • 2011
  • This paper introduces a robot eye module, of which two degree-of-freedom motions, i.e. panning and tilting, are driven by a pair of wires. The main feature of the module is that each wire can generate push-pull motion without buckling. It is thanks to a Teflon tube which guides the path of the moving wire. End points of the tube and wire have pivot elements so that a smooth push-pull motion is produced even when the end point of wire is moved by eye rotation. This mechanism helps the eye module to be very compact. In this paper, the structure of the robot eye module is introduced in detail, and the required motor angles for a certain direction of eye line are investigated analytically and experimentally.

레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석 (The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone)

  • 곽이구;안재신;김재열
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

진공청소기 팬 모터의 진동 및 소음원인 분석을 위한 유동해석 (The Flow Analysis for Vibration and Noise Diagnostic of Vacuum Cleaner Fan Motor)

  • 김재열;곽이구;안재신;양동조;송경석;박기형
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.56-63
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

차량용 MR 팬 클러치 설계 및 제어 (Design and Control of MR Fan Clutch for Automotive Application)

  • 김은석;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.633-638
    • /
    • 2009
  • This paper presents an optimal design of a magnetorheological(MR) fan clutch based on finite element analysis and also presents torque control of engine cooling fan using a sliding mode control. The MR fan clutch is constrained in a specific volume and the optimization problem identifies the geometric dimension of the fan clutch that minimizes an objective function. The objective function for the optimization problem is determined based on the solution of the magnetic circuit of the initially designed clutch. Under consideration of spatial limitation, design parameters are optimally determined using finite element analysis. After describing the configuration of the MR fan clutch, the viscous torque and controllable torque are obtained on the basis of the Bingham model of MR fluid. Then, a sliding mode controller is designed to control the torque of the fan clutch according to engine room temperature and control performance is evaluated through computer simulation.

  • PDF