Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Analysis of Reinforced Concrete Panel subjected to Blast Load using Parallel and Domain Decomposition (병렬과 영역분할을 이용한 폭발하중을 받는 철근콘크리트패널의 해석)

  • Park, Jae-Won;Yun, Sung-Hwan;Park, Tae-Hyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.365-373
    • /
    • 2011
  • Damage of reinforced concrete panel subjected to blast load using parallel and domain decomposition is analyzed. The numerical results are sensitive to the mesh size because blast waves are generated during the extremely short term. In order to investigate the effect of mesh size on the blast wave, the analysis results from various wave mesh size using AUTODYN, the explicit finite element analysis program, were compared with existing experimental results. The smaller mesh size was, the higher accuracy was. However, in this case, the analysis was inefficient. Therefore, in order to increase numerical efficiency, the parallel analysis using decomposed method based on Euler and Lagrangian description was performed. Finally, the decomposed method using both the structure domain based on Lagrange description and the blast wave domain based on Euler description was more efficient than the decomposed method using only the Lagrange mesh on structure domain.

Circuit Modeling and Analysis of Touch Screen Panel (터치스크린 패널의 회로 모델링 및 분석)

  • Byun, Kisik;Min, Byung-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2014
  • A simple RC circuit model of large-scale touch screen panels is developed and the frequency range of the RC model is analyzed. 2D EM simulation results of a single touch cell are cascaded for a 23 inch touch panel using a circuit simulator, and the shortest and longest channels of the full panel are modeled with a 5-element RC circuit. The 5-element RC circuit can model the touch screen panel upto 130 kHz with the channel phase error of $10^{\circ}$. 7-element RC circuit model is also proposed and the frequency range for the channel phase error of $10^{\circ}$ is extended to 200 kHz.

Comparison of score-penalty method and matched-field processing method for acoustic source depth estimation (음원 심도 추정을 위한 스코어-패널티 기법과 정합장 처리 기법의 비교)

  • Keunhwa Lee;Wooyoung Hong;Jungyong Park;Su-Uk Son;Ho Seuk Bae;Joung-Soo Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.314-323
    • /
    • 2024
  • Recently, a score-penalty method has been used for the acoustic passive tracking of marine mammals. The interesting aspect of this technique lies in the loss function, which has a penalty term representing the mismatch between the measured signal and the modeled signal, while the traditional time-domain matched-field processing is positively considering the match between them. In this study, we apply the score-penalty method into the depth estimation of a passive target with a known source waveform. Assuming deep ocean environments with uncertainties in the sound speed profile, we evaluate the score-penalty method, comparing it with the time-domain matched field processing method. We shows that the score-penalty method is more accurate than the time-domain matched field processing method in the ocean environment with weak mismatch of sound speed profile, and has better efficiency. However, in the ocean enviroment with strong mismatch of the sound speed profile, the score-penalty method also fails in the depth estimation of a target, similar to the time-domain matched-field processing method.

TFT-LCD Defect Detection Using Mean Difference Between Local Regions Based on Multi-scale Image Reconstruction (로컬 영역 간 평균 화소값 차를 이용한 멀티스케일 기반의 TFT-LCD 결함 검출)

  • Jung, Chang-Do;Lee, Seung-Min;Yun, Byoung-Ju;Lee, Joon-Jae;Choi, Il;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.439-448
    • /
    • 2012
  • TFT-LCD panel images have non-uniform brightness, noise signal and defect signal. It is hard to divide defect signal because of non-uniform brightness and noise signal, so various divide methods have being developed. In this paper, we suggest method to divide defective regions on TFT-LCD panel image by estimating a menas of two different size of windows, which is suggested by Eikvil et al., and using difference of them. But in this method, the size of detectable defects is restricted by the size of window, hence it has inefficient problem that the size of window have to increase to divide a large defect region. To solve this problem we suggest an algorithm which can divide various size of defects, by using Multi-scale and restrict a detectable size of defects in each scale. To prove an efficiency of suggested algorithm, we show that resulting images of real TFT-LCD panel images and an artificial image with various defects.

한국 소프트웨어 기술혁신의 구조 변동

  • Choe, Yong-Jin
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2017.05a
    • /
    • pp.619-619
    • /
    • 2017
  • 현대사회의 제품생산과 기업활동에서 소프트웨어의 중요성과 그 가치가 날로 높아져 가는 가운데 소프트웨어 기술혁신은 과거 소프트웨어 산업 영역에 국한되었던 비교적 작은 구조에서 이제는 다양한 산업 영역에서 다발적으로 일어나는 보다 넓은 구조로 변모하고 있다. 이 연구에서는 한국 출원인이 포함된 약 270만 건의 특허 메타데이터와 기업정보 데이터를 활용한 패널데이터를 구축하여 한국 산업계 전반에 걸쳐 일어나고 있는 소프트웨어 기술혁신의 구조 변동 현상을 밝혀내고, 이를 토대로 정부의 소프트웨어 산업 정책에 관한 함의를 도출하고자 한다. 이 연구는 다음의 네 부분으로 구성이 된다. 첫째, 최근 여러 분야에서 일어나고 있는 소프트웨어와 타 산업 간의 융합 현상과 이에 대한 이론적 논의를 전개한다. 둘째, 연구에 활용 할 데이터와 실증분석 방법론에 관하여 논의한다. 셋째, 패널분석을 기초로 한 실증분석을 수행하고, 그 결과를 제시한다. 넷째, 한국정부의 소프트웨어 산업 정책을 살펴보고, 이를 바탕으로 실증분석 결과가 지니는 함의에 관하여 논의한다.

  • PDF

Automatic TFT-LCD Mura Defect Detection using Gabor Wavelet Transform and DCT (가버 웨이블렛 변환 및 DCT를 이용한 자동 TFT-LCD 패널 얼룩 검출)

  • Cho, Sang-Hyun;Kang, Hang-Bong
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.525-534
    • /
    • 2013
  • Recently, mura defect inspection techniques are receiving attention in LCD production procedure since demands of TFT-LCD are growing. In this paper, we propose an automatic mura defect inspection method using gabor wavelet transform and DCT. First, we generate a reference panel image using DCT based method. For original panel image and generated reference panel image, we apply a gabor wavelet transform to eliminate texture information in images. Then, we extract mura defect regions from the difference image between gabor wavelet transform image of original panel and generated reference panel image. Finally, all mura defect regions are quantified to detect accurate mura defects. Experimental results show that our method is more accurate and efficient than previous methods.

Aerodynamic Analysis of the Blended Wing Body Type MAV using the Time-Domain Panel Method (시간영역 패널법을 이용한 융합익기 형상 초소형 무인기의 공력해석)

  • Park, Jin-Han;Cho, Lee-Sang;Cho, Jin-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.7
    • /
    • pp.637-646
    • /
    • 2010
  • A time-domain panel method based on the potential flow theory and the time-stepping method is developed to predict the steady/unsteady aerodynamic characteristics of FM07, which is the BWB (Blended-wing body) type MAV. In the aerodynamic analyses, we used two types of the initial model(Case I) and the improved model(Case II), which is moved the gravity center toward the rear and has larger aspect ratio. In the steady aerodynamic analyses, it is revealed that improved model has higher lift to drag ratio(L/D) and more stable pitch characteristic than those of the initial model. In the unsteady aerodynamic analyses for sudden acceleration motion similar to the launch phase of MAV, it seemed that there is a rapid increase of the lift coefficient after the launch and unsteady results are good agreed compare with steady results in just a few times. In the analysis for pitch oscillation motion, which is occurred at the cruise condition of the FM07, it shows that unsteady aerodynamic coefficients looped around steady results and the improved model has more sensitive aerodynamic characteristics.

Enhancement of the Bright Room Contrast Ratio in a Plasma Display Panel (플라스마 디스플레이 패널에서 명실 콘트라스트 개선)

  • Moon, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • A new electrode structure in a plasma display panel was designed in a way to increase the bright room contrast ratio (BRCR). The area of the black matrix pattern to get a low reflection from the panel surface was enlarged using the new electrode design concept. The electrical characteristics such as firing voltage, voltage margin and power consumption were measured. The luminance of the panel was measured and the luminous efficiency was calculated. It was found that the new electrode structure was very effective to enhance the BRCR.

Image Mixing in Multiview 3 Dimensional Imaging Systems (다시점 3차원 영상 시스템에서 영상혼합)

  • Kim, Shin-Hwan;Son, Jung-Young
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.2
    • /
    • pp.175-181
    • /
    • 2008
  • A 2 dimensional quality function for quantifying the quality of images observed at viewing regions in contact-type multiview 3 dimensional imaging systems is devised and its effectiveness is verified experimentally. The function allows calculating the locations of viewing regions for patched images of any number of different view images. The images observed at the calculated regions reveal that different parts of the display panel of the system project different view images and match with the function's prediction.