• Title/Summary/Keyword: 파형도

Search Result 2,914, Processing Time 0.023 seconds

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Analysis on dynamic numerical model of subsea railway tunnel considering various ground and seismic conditions (다양한 지반 및 지진하중 조건을 고려한 해저철도 터널의 동적 수치모델 분석)

  • Changwon Kwak;Jeongjun Park;Mintaek Yoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.583-603
    • /
    • 2023
  • Recently, the advancement of mechanical tunnel boring machine (TBM) technology and the characteristics of subsea railway tunnels subjected to hydrostatic pressure have led to the widespread application of shield TBM methods in the design and construction of subsea railway tunnels. Subsea railway tunnels are exposed in a constant pore water pressure and are influenced by the amplification of seismic waves during earthquake. In particular, seismic loads acting on subsea railway tunnels under various ground conditions such as soft ground, soft soil-rock composite ground, and fractured zones can cause significant changes in tunnel displacement and stress, thereby affecting tunnel safety. Additionally, the dynamic response of the ground and tunnel varies based on seismic load parameters such as frequency characteristics, seismic waveform, and peak acceleration, adding complexity to the behavior of the ground-tunnel structure system. In this study, a finite difference method is employed to model the entire ground-tunnel structure system, considering hydrostatic pressure, for the investigation of dynamic behavior of subsea railway tunnel during earthquake. Since the key factors influencing the dynamic behavior during seismic events are ground conditions and seismic waves, six analysis cases are established based on virtual ground conditions: Case-1 with weathered soil, Case-2 with hard rock, Case-3 with a composite ground of soil and hard rock in the tunnel longitudinal direction, Case-4 with the tunnel passing through a narrow fault zone, Case-5 with a composite ground of soft soil and hard rock in the tunnel longitudinal direction, and Case-6 with the tunnel passing through a wide fractured zone. As a result, horizontal displacements due to earthquakes tend to increase with an increase in ground stiffness, however, the displacements tend to be restrained due to the confining effects of the ground and the rigid shield segments. On the contrary, peak compressive stress of segment significantly increases with weaker ground stiffness and the effects of displacement restrain contribute the increase of peak compressive stress of segment.

The Clinical Features of Endobronchial Tuberculosis - A Retrospective Study on 201 Patients for 6 years (기관지결핵의 임상상-201예에 대한 후향적 고찰)

  • Lee, Jae Young;Kim, Chung Mi;Moon, Doo Seop;Lee, Chang Wha;Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.671-682
    • /
    • 1996
  • Background : Endobronchial tuberculosis is definded as tuberculous infection of the tracheobronchial tree with microbiological and histopathological evidence. Endobronchial tuberculosis has clinical significance due to its sequela of cicatrical stenosis which causes atelectasis, dyspnea and secondary pneumonia and may mimic bronchial asthma and pulmanary malignancy. Method : The authors carried out, retrospectively, a clinical study on 201 patients confirmed with endobronchial tuberculosis who visited the Department of Pulmonary Medicine at Hangyang University Hospital from January 1990 10 April 1996. The following results were obtained. Results: 1) Total 201 parients(l9.5%) were confirmed as endobronchial tuberculosis among 1031 patients who had been undergone flexible bronchofiberscopic examination. The number of male patients were 55 and that of female patients were 146. and the male to female ratio was 1 : 2.7. 2) The age distribution were as follows: there were 61(30.3%) cases in the third decade, 40 cases(19.9%) in the fourth decade, 27 cases(13.4%) in the sixth decade, 21 cases(10.4%) in the fifth decade, 19 cases(9.5%) in the age group between 15 and 19 years, 19 cases(9.5%) in the seventh decade, and 14 cases(7.0%) over 70 years, in decreasing order. 3) The most common symptom, in 192 cases, was cough 74.5%, followed by sputum 55.2%, dyspnea 28.6%, chest discomfort 19.8%, fever 17.2%, hemoptysis 11.5%, in decreasing order, and localized wheezing was heard in 15.6%. 4) In chest X-ray of 189 cases, consolidation was the most frequent finding in 67.7%, followed by collapse 43.9%. cavitary lesion 11.6%, pleural effusion 7.4%, in decreasing order, and there was no abnormal findings in 3.2%. 5) In the 76 pulmanary function tests, a normal pattern was found in 44.7%, restrictive pattern in 39.5 %, obstructive pattern in 11.8%, and combined pattern in 3.9%. 6) Among total 201 patients, bronchoscopy showed caseous pseudomembrane in 70 cases(34.8%), mucosal erythema and edema in 54 cases(26.9%), hyperplastic lesion in 52 cases(25.9%), fibrous s.enosis in 22 cases(10.9%), and erosion or ulcer in 3 cases(1.5%). 7) In total 201 cases, bronchial washing AFB stain was positive in 103 cases(51.2%), bronchial washing culture for tuberculous bacilli in 55 cases(27.4%). In the 99 bronchoscopic biopsies, AFB slain positive in 36.4%. granuloma without AFB stain positive in 13.1%, chronic inflammation only in 36.4%. and non diagnostic biopsy finding in 14.1%. Conclusions : Young female patients, whose cough resistant to genenal antitussive agents, should be evaluated for endobronchial tuberculosis, even with clear chest roentgenogram and negative sputum AFB stain. Furthermore, we would like to emphasize that the bronchoscopic approach is a substantially useful means of making a differential diagnosis of atelectasis in older patients of cancer age. At this time we have to make a standard endoscopic classification of endobronchial tuberculosis, and well designed prospective studies are required to elucidate the effect of combination therapy using antituberculous chemotherapy with steroids on bronchial stenosis in patients with endobronchial tuberculosis.

  • PDF