The purpose of this study was to evaluate the shear bond strength between various resin-bonded retainers and enamel according to the adhesive resins and retention types and observe the bond filure modes with scanning electron microscope(SEM). For this purpose, the followin eight sub-groups were tested in shear bond strength : 1) electrochemically etched group(Verabond) using Panavia EX and Superbond C&B 2) tin-plated group(PG-S) using Panavia EX and Superbond C&B 3) salt-treated group(Verabond) using Panavia EX and Superbond C&B 4) meshtreated group(Verabond) using Panavia EX and Superbond C&B. Thermocycling test was conducted on the condition of 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$bath. Shear bond strength was measured by Instron Universal Testing Machine(medel 1125). The obtained results were as follows : 1. After thermocycling, the shear bond strengths of tin-plated group and electrochemically etched group were significantly greater than those of salt-treated group and mesh-treated group. And the shear bond strength of Panavia EX was greater than that of Superbond C&B with salt-treated group and tin-plated group(p<0.05). 2. Before thermocycling, electrochemically etched group using Superbond C&B produced the greatest shear bond strength(p<0.01). 3. The shear bond strength of electrochemically etched group using Superbond C&B was significantly decreased after thermocycling(p<0.01). 4. In observation of bond failure modes before thermocycling, Panavia EX highly exhibited enamel fracture. Tin-plated group using Superbond C&B adhesive failure between metal and resin and electrochemically etched group using Superbond C&B exhibited adhesive failure between enamel and rdsin. 5. In observation of failure modes after thermocycling, Panavia EX exhibited cohesive failure and Superbond C&B exhibited adhesive failure between resin and metal.
소아치과 임상에서 자주 사용되는 3 종의 광중합형 GIC의 아말감에 대한 접착능을 평가 할 목적으로 60 개의 아말감 부착시편을 이용하여 중간결합제인 Scotchbond 의 사용여부에 따른 경화된 아말감에 대한 광중합 GIC의 전단결합강도를 측정하고 경계부의 파절양상을 관찰한 결과, 다음과 같은 결론을 얻었다. 1. 아말감에 대한 광중합형 GIC의 전단강도는 Fuji II LC, Vitremer, Vitrebond의 순으로 높게 나타났다 (p<0.05). 2. 중간결합제인 Scotchbond를 사용하지 않은 경우에서 Scotchbond 를 사용한 경우에 비해 전단결합강도가 높게 나타났다(p<0.05). 3. 결합파절면은 Scotchbond를 사용한 경우의 대부분에서 Scotchbond와 아말감의 경계부에서 시편의 탈락이 나타났다. 아말감과 광중합 GIC의 결합을 시도할 경우에는 Scotchbond는 사용하지 않는 것이 바람직할 것으로 사료되었다.
Light-cured orthodontic composite resin has been widely advertised recently for use in bonding brackets. However, the curability of light-cured resin when light waves are diffused through metal brackets in questionable. The purposes of this study were to evaluate shear bond strength and failure patterns of visible light-cured resin(Lightbond) and chemically cured-resin(Mono-Lok 2), and to determine the relative value of light-cured resin as an alternative to conventional chemically cured resin. Each of the two resins was tested on twenty extracted human first premolars. Standard edgewise metal brackets were bonded to the teeth in accordance with the manufacturers' recommendation. After bonding, the teeth were stored for 24 hours at $37^{\circ}C$, 100% humidity. The shear bond strength was tested with a universal testing machine(Instron 4302), at 0.5mm/min crosshead speed. After debonding, brackets and enamel surfaces were examined with a scanning electron microscope and a stereoscopic microscope. The results were as follows : 1. Metal brackets bonded with Lightbond showed statistically higher shear bond strength than metal brackets bonded with Mono-Lok2. 2. The predominant failure site in Lightbond was the enamel-resin interface, and in Mono-Lok 2 it was the resin itself. 3. Enamel cracks were not found in any specimen. The above results suggest that direct bonding of metal brackets to enamel with light-cured resin bonding agent can be used effectively in clinics.
본 연구의 목적은 시중에 유통되고 있는 밴드 시멘트들을 종류별로 이용하여 교정용 밴드의 결합강도를 비교하고, 각 시멘트의 파절 양상을 비교하여 교정용 밴드에 대한 사용지침을 마련하는데 도움이 되고자 하였다. 100개의 발거된 인간의 제 3대구치를 이용해 실험군은 총 5개의 군으로 하였으며, 각 군당 시편수가 20개가 되도록 임의적으로 분류하였다. 실험에 사용한 밴드 시멘트는 다음과 같다; Ormco gold, Ultra $Band-Lok^{TM}$, Fuji $Ortho^{TM}$ LC, 3M $Unitek^{TM}$ Multi-Cure Glass Ionomer, $Ketac-Cem^{TM}$. Universal testing machine(Instron Corp., Canton, MA, USA)를 사용하여 최대하중값을 측정하였고, 전단결합강도 값을 계산하였다. 밴드가 탈락한 후, 탈락 부위를 평가하여 법랑질과 시멘트, 시멘트와 밴드 사이로 구분하였다. 밴드의 전단강도는 One-way ANOVA를 이용하여 통계처리 하였으며 Tukey test를 이용하여 검정하였다. 또한 탈락 부위는 Chi-squre analysis를 이용하여 통계 처리하였고, Fisher's exact test로 군간 유의성을 검정하였다. 실험 결과 평균 파절 강도는 Ormco군이 가장 높았고(2.44${\pm}$0.57), Fuji $Ortho^{TM}$군(2.24${\pm}$0.50), $Ketac-Cem^{TM}$군(2.10${\pm}$0.57), 3M $Unitek^{TM}$군(1.82${\pm}$0.43), $Band-Lok^{TM}$군(1.73${\pm}$0.28) 순이었으며, Ormco군은 $Band-Lok^{TM}$군과 3M $Unitek^{TM}$군, Fuji $Ortho^{TM}$군은 $Band-Lok^{TM}$군과만 통계적으로 유의할만한 차이를 보였다(p<0.05). 파절 양상에서 Ormco군과 $Band-Lok^{TM}$군은 서로뿐만 아니라 다른 군과 유의할만한 차이를 보였으며, Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$ 군 간에는 유의한 차이가 없었다.
침식 법랑질의 표층은 건전 법랑질과는 물리화학적 성상이 다르므로 침식 법랑질면에 대한 복합레진의 결합력을 증가시키기 위한 대안으로, 법랑질 내층으로의 침투력이 탁월한 infiltrant resin을 응용하는 방법을 생각하게 되었다. 본 연구는 다양한 정도로 인공 침식이 유발된 법랑질면을 대상으로, infiltrant resin과/또는 기존의 접착제를 적용한 경우의 복합레진 결합강도를 비교 분석할 목적으로 시도되었다. 건전한 순면을 가진 발거된 상악 유전치를 대상으로, 인공침식 유발 횟수 및 infiltrant resin과/또는 기존의 접착제를 적용한 방법에 따라 각 20개씩의 시료를 제작하였으며, 각 군의 미세인장 결합강도를 측정하고, 파절면의 파절 양상을 평가하여 다음과 같은 결과를 얻었다. 법랑질 표면의 침식 유발 횟수가 늘어날수록 결합강도가 낮았다(p<0.05). 기존의 접착제 상부에 infiltrant resin을 추가 적용한 군, infiltrant resin만 적용한 군, 접착제만 적용한 군의 순으로 미세인장결합강도가 높게 나타났다(p<0.05). 파절 양상의 관찰에서는 인공 침식 유발 횟수가 적은 군 및 infiltrant resin을 적용한 군에서 응집파절의 비율이 높게 나타났다. 결론적으로, 법랑질의 침식도가 클수록 복합레진 수복물과의 결합 강도는 감소하였으며, infiltrant resin으로 기존의 적찹제를 대체하거나 첨가함으로써 결합강도를 보완시킬 수 있을 것으로 판단되었다.
성인 환자의 증가와 심미적인 장치에 대한 요구가 증가하면서 도재나 레진 브라켓의 사용이 증가되고 있다. 이러한 브라켓에서의 광중합 접착제의 사용은 짧은 광조사 시간에서도 광중합 접착제의 많은 장점을 얻을 수 있다. 이에 본 연구에서는 심미적으로 우수한 수 종의 도재 및 레진 브라켓을 수 종의 광중합 접착제로 접착시켜 전단 접착 강도와 접착 파절 양상을 관찰하였다. 교정 치료를 위해 발거한 140개의 소구치를 협측면이 노출되도록 자가중합 레진으로 매몰하고 소구치 협측면에 Plastlc bracket, Transcend 6000, Signature 및 Starfire TMB 브라켓을 Orthobond, Light Bond 및 Transbond로 제조자 지시에 따라 접착시켜 열변환기 로 1800회 온도 변화를 준 후 전단 접착 강도를 만능시험기로 측정하고 접착 파절 양상을 입체현미경으로 관찰하였고 10초와 20초의 광조사 시간과 두가지 광원에 대해 전단 접착 강도를 비교하여 다음의 결과를 얻었다. 1. 동일한 브라켓을 Orthobond, Light Bond와 Transbond로 접착시켰을 때 이들간의 전단 접착 강도는 Plastic bracket을 제외하고는 통계학적 유의차가 없었다(p<0.05). 2. 동일한 접착제로 Plastic bracket, Transcend 6000, Signature, Starfire TMB를 접착시켰을 때 이들간의 전단 접착강도는 통계학적 유의차를 보였다(p<0.05). Starfire TMB에서 가장 큰 전단 접착강도를 보였고 이는 Transcend 6000과 통계학적 유의차가 없었으나 Singnature와는 통계학적 유의차를 보였다(p<0.05). 3. 접착 파절은 전체 군에서 잔류 접착제가 반 이상 또는 모두 치아면에 남은 경우가 $72.1\%$로 대개 브라켓과 접착제 사이에서 파절이 일어났다. 4. 접착제 중합을 위한 광조사 시간은 10초와 20초에서 전단 접착 강도에 통계학적 유의차를 보이지 않았으며 $400mW/cm^2$ 이상의 광도에서는 서로 다른 광원을 사용해도 전단 접착 강도에 통계학적 유의차를 나타내지 않았다(p<0.05). 이상의 결과로 보아 도재 브라켓의 전단 접착강도는 브라켓 조성과 브라켓 접착면의 유지형태 차이에 의해 영향을 받고 광중합 접착제 종류에 따른 접착 강도의 차이는 나타나지 않았으며 임상에서 브라켓이나 접착제 선택시 이를 고려해야 할 것으로 사료된다.
목적. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합레진의 전단결합강도를 비교 평가하고자 하였다. 재료 및 방법. 레진 블록 시편의 제작방식에 따라 4개의 군으로 나누었고 subtractive manufacturing (SM), additive manufacturing stereolithography apparatus (AMS), additive manufacturing digital light processing (AMD), conventional self-curing (CON)의 방식으로 각 20개씩 레진 시편을 제작하였다. 제작 방식에 따른 레진 블록 시편과 재이장용 자가중합레진의 결합을 위해 시편의 표면에 실리콘 몰드를 이용하여 동일한 위치에 재이장 레진을 주입하여 중합하였다. 만능재료시험기를 이용하여 전단결합강도를 측정하였고 주사전자현미경으로 접착 계면의 파절 양상을 확인하였다. 실험군 간 비교를 위해 일원배치 분산분석과 사후 검정으로 Tukey test를 실시하였다(α = .05). 결과. 전단결합강도는 CON, SM, AMS, AMD군 순으로 높았다. CON군은 AMS군, AMD군과 유의한 차이가 있었고(P < .01) SM군과 유의한 차이가 없었다(P > .05). SM군은 AMD군과 유의한 차이가 있었고(P < .01) AMS군과 유의한 차이가 없었다(P > .05). AMS군은 AMD군과 유의한 차이가 있었다(P < .001). 파절 양상은 CON군, AMS군에서 혼합 파절이 높은 빈도로 나타났으며 SM군, AMD군에서 접착 파절이 높은 빈도로 나타났다. 결론. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합 레진과의 전단결합강도에서 절삭 가공 방식(SM군)은 CON군보다 낮은 결합강도를 보였지만 유의한 차이를 보이지 않았다. 적층 가공 방식(AMS군, AMD군)은 CON군보다 유의하게 낮은 결합강도를 보였으며, AMD군이 가장 낮은 결합강도를 보였고 AMD군은 SM군과도 유의한 차이를 보였다.
Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.
목적: 본 연구는 Co-Cr, Ti-6Al-4V 합금에 Zirconium Nitride (이하 ZrN) 적용 시, 의치상 레진과의 접착력을 비교하는 것이다. 연구 재료 및 방법: Co-Cr, Ti-6Al-4V 디스크(직경 10 mm, 두께 2.5 mm)를 각각 14개씩 제작하였고, ZrN 코팅에 따라 2개의 그룹으로 나누었다. Primer로 시편 전처리 후, 의치상 레진(직경 6 mm, 두께 5 mm)을 부착하였다. 표면 측정기를 이용하여 시편의 거칠기를 측정한 후, 만능 시험기를 이용하여 전단결합강도를 측정하였으며, 이원분산분석으로 통계 분석하였다. 시편 표면과 파절 양상을 주사전자현미경을 이용하여 관찰하였다. 결과: ZrN을 코팅한 시편에서 유의하게 높은 표면 거칠기를 나타내었고(P < 0.05), 전단결합강도는 낮았다(P < 0.001). ZrN 코팅 시편에서는 혼합성 파절과 부착성 파절이 함께 나타났다. 결론: Co-Cr, Ti-6Al-4V 합금에서 ZrN 코팅 처리는 의치상 레진과의 결합력을 약화시켰다.
목적: 중합방식과 화학적 조성이 다른 본딩제들이 자가중합형 비스아크릴 임시수복 재료의 결합에 미치는 영향을 알아 보고자 하였다. 연구 재료 및 방법: 원반 형태의 비스아크릴 임시수복 재료 시편 40개를 준비한 후 본딩제의 중합특성에 따라 대조군을 포함 4개의 군으로 나누었다. 본딩제 도포 후 직경 4 mm의 원형 구멍을 가진 4 mm 두께의 테플론 몰드를 이용하여 동일한 비스아크릴 임시수복 재료을 첨상하였다. 전단결합강도시험을 시행하였으며 파절면을 현미경으로 관찰하였다. 일원배치 분산분석과 Tukey 사후분석을 사용하여 유의수준 0.05로 검증하였다. 결과: 화학중합형 본딩제를 사용한 군에서 통계적으로 유의한 가장 높은 전단결합강도를 보였으며($27.36{\pm}4.30 MPa$, P < 0.05) 모든 시편에서 비스아크릴 임시수복 재료 내에서 파절이 일어나는 응집성 파절 양상을 보였다(100%). 실험군중 가장 낮은 값은 광중합형 본딩제를 사용한 군에서 기록되었으며($13.29{\pm}2.56 MPa$) 이는 대조군과 거의 유사한 값을 보였다. 동일한 광중합 방식 이지만 화학중합 레진과의 호환성을 높인 본딩제를 사용한 군에서는 광중합형 본딩제를 사용한 군에 비해 통계적으로 유의하게 높은 값을 보였다(P = 0.043). 결론: 본딩제의 종류가 수리된 비스아크릴 임시수복 재료의 전단결합 강도에 영향을 주며, 비스아크릴 임시수복 재료의 수리 시 적절한 본딩제 선택이 중요하다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.