• Title/Summary/Keyword: 파랑 시뮬레이션

Search Result 1,095, Processing Time 0.026 seconds

A Study on Selected Harmonic Control Method for PW Inverter by Fluctuating input Voltage Method (PWM 인버터의 DC 링크 맥동전압 제어에 의한 특정 고조파 제어기법)

  • 전희종;박재원;오종민;정을기;정인성
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.6
    • /
    • pp.51-59
    • /
    • 1993
  • In this paper, we study the effects that the variations of machine parameters and frequency of which affect the instability occured in induction motors when operated at low speed or light load, by obtaining the locus of dominant root for the characteristic equation.

  • PDF

A Study on Harmonic Analysis and Countermeasure at the High Speed Railway Substation (고속전철 변전소의 고조파 분석과 대책에 관한 연구)

  • 김재철;박수만;강창원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.138-143
    • /
    • 2004
  • This paper analyzed harmonics from high speed railway traction to high speed railway substation and provide a reduction method of harmonics using the passive filter. A substation supplies the electric power to a train or can supply the electric power to several trains. According to the number of trains covered by a substation, characteristics of harmonics are investigated. These harmonics affect transformer heating and inductive interference. In order to get rid of the damage from the harmonics, this paper presented minimizing method of harmonics. The proposed method is verified in simulation using the PSCAD/EMTDC.

Harmonic Characteristics and Circulating Current Analysis of New Offset Voltage Control for MMC HVDC System (HVDC 용 MMC의 새로운 오프셋 전압제어에 따른 고조파 및 순환전류 분석)

  • Kim, Jae-Hyuk;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.30-32
    • /
    • 2018
  • 본 논문에서는 고압 직류송전용 MMC에 오프셋 전압 제어를 적용하는 데 있어 3고조파 주입기법과 제안하는 가변오프셋 전압 제어 기법에 따른 시스템의 고조파 특성과 순환전류 특성에 대해 비교 분석한 내용을 기술하고 있다. 제안한 가변오프셋 전압 제어는 MI(Modulation Index)에 따라 오프셋 전압의 크기를 가변 하여 MMC 출력 상전압이 항상 N+1 레벨을 형성하는 기법이다. 제안하는 기법과 3고조파 주입기법의 비교를 위해 200MW MMC HVDC 시스템에 적용하여 PSCAD/EMTDC 시뮬레이션을 수행하였다. 제안한 기법은 오프셋 전압제어 적용에 따라 발생할 수 있는 고조파 특성에 있어 3고조파 주입기법에 비해 우수함을 확인하였다. 또한 제안하는 기법을 사용할 경우 오프셋 전압에 의한 4고조파 순환전류 저감이 가능함을 알 수 있었다.

  • PDF

Analysis on Mechanism of Wave Attenuation under Wave-Current Interaction (파랑-흐름의 상호작용에 의한 파랑변형 메커니즘 분석)

  • Lee, Woo-Dong;Hur, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.645-650
    • /
    • 2016
  • In this study, we conducted a numerical simulation using Navier-Stokes Solver (HYMO-WASS-3D) in order to analyze wave attenuation under wave-current interaction found in existing hydraulic experiments. It showed that wave energy and wave height are reduced as the wave propagates in coexisting fields between waves and currents. And the wave attenuation became more serious as the velocity of current and thus turbulence intensity were increased at wave-current coexisting field. As well, the wave attenuation became more serious with lower wave height and shorter period when the wave propagates the same distance under interactions between waves and currents.

Vibration Analysis During Breaking Process of Phantom Induced by Shock Wave for Medical Treatment (의료용 충격파에 의할 대상물의 파쇄진행에 따른 진동해석)

  • Park Kyu-Chil;Jang Yun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2006
  • When the vibration of a phantom induced by Extracorporeal Shock Wave Lithotripter (ESWL) was investigated. we found the fact that the Peak frequency in the Power spectrum shifts from high frequency to low frequency as the number of shots increases[2]. The fact was confirmed experimentally by detecting the peak frequency obtained from the vibrations of bronze models[3]. This Paper investigates the experimental results. For the Purpose. we carried out the computer simulation using the finite element method. It is found that the results from the experiments are computer by computer simulation.

Compensation of Harmonic Distortion for Grid-connected Inverter Systems using a PR Controller (비례공진 제어기를 이용한 계통연계형 인버터의 고조파 왜곡보상)

  • Lee, Jong-Hyun;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.215-216
    • /
    • 2011
  • 본 논문에서는 계통연계 태양광발전 시스템에서 계통전압의 왜곡을 보상하는 전류제어기법을 제안한다. 계통전압의 왜곡을 보상하기 위해 기존의 고조파 제어기를 비례-공진 제어기로 대체하여 계통전류의 고조파를 제거한다. 제안하는 기법은 동기좌표축 상에서 설계하는 기존의 방법과는 다르게 복잡한 연산이 필요하지 않은 장점이 있다. 시뮬레이션과 실험을 통해 제안된 알고리즘의 우수한 제어특성을 확인한다.

  • PDF

A Pseudo Random Frequency Carrier(PRC) Generator (준 랜덤 주파수 캐리어(PRC) 발생기)

  • Park, J.K.;Kim, J.N.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.157-160
    • /
    • 2005
  • 본 연구에서는 고정 주파수의 캐리어 합성만으로 랜덤 주파수의 캐리어를 간단하게 발생하는 방법을 제안하였다. 고정 주파수를 갖는 삼각파 캐리어와 그 역상의 삼각파 캐리어를 랜덤 비트 발생기(PRBS : Pseudo Random Binary Sequence)에 의하여 선택하여 랜덤 주파수 캐리어를 새롭게 합성 할 수 있다. 실험과 시뮬레이션에 의하여 PRBS의 시트프 레지스터의 비트별 고조파 스펙트럼을 비교 고찰하였다.

  • PDF

Controller Design of Grid-Connected Inverter to Compensate Harmonics (고조파 보상을 위한 계통연계형 인버터 제어기 설계)

  • Sin, Chanho;Simatupang, Desmon Petrus;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.441-442
    • /
    • 2017
  • 본 논문에서는 계통연계 인버터가 액티프 파워 필터로 동작할 때 비선형부하에 의해 발생하는 고조파를 보상하는 제어기 설계에 대해 다룬다. 고조파 보상 기능을 포함하는 계통연계형 인버터의 제어기는 PR제어기 기반의 멀티루프 전류제어기를 사용한다. 각각의 제어기는 시스템 특성 및 안정도를 고려하여 설계되고 시뮬레이션 및 실험으로 타당성을 입증한다.

  • PDF

Design and analysis of input finer for 3 Phase Matrix Converter (매트릭스 컨버터 입력 LC 필터 설계 및 분석)

  • Cha, Han-Ju;Kim, Woo-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.146-148
    • /
    • 2009
  • 본 논문에서는 매트릭스 컨버터의 입력 필터 설계를 하고, 시뮬레이션하여 타당성을 검증하고 분석한다. 매트릭스 컨버터는 18개의 양방향 스위치로 구성되어 있으며, 출력 전압을 합성하기 위해 각각의 스위치가 빠르게 온-오프 한다. 이러한 스위칭 과정에서 고차 고조파가 발생하고, 이 고조파는 매트릭스 컨버터 주위에 연결된 각종 기기에 영향을 미친다. 따라서 고차 고조파를 줄이기 위해 계통과 매트릭스 컨버터 사이에 입력 필터를 설치하여 이러한 영향을 줄여야 한다. 입력 필터의 L과 C, 그리고 공진 주파수 근처의 값을 줄이기 위한 댐핑 저항 값을 계산하는 방법을 소개하고, 타당성을 검증한다.

  • PDF