• Title/Summary/Keyword: 파과곡선

Search Result 71, Processing Time 0.029 seconds

The Mixed-Bed Ion Exchange Performance and Temperature Effects at Ultra-Low Concentrations - 2.Temperature Effects - (초저이온 농도범위에서 혼합층 이온교환능과 온도의 영향 - 2. 온도의 영향 -)

  • Yoon, Tae Kyung;Noh, Byeong Il;Lee, Chang Won;Moon, Byung Hyun;Lee, Gang Choon;Jo, Myung Chan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.206-211
    • /
    • 1999
  • Mixed-bed ion exchange performance was studied experimentally with variations of cation to anion resin ratio, resin weight and temperature at ultralow sodium chloride solution concentrations of less than $1.0{\times}10^{-4}M$. Analyzing the effluent concentration histories the performance test was examined as a function of tested solution volume for a laboratory-scale continuous flow column until both the cation and anion-exchange resins were exhausted. Initial leakage was observed for both cation and anion breakthrough curves, but serious at cation breakthrough curve because of low selectivity coefficient. The slope of breakthrough curve was affected by selectivity coefficient and temperature. The slope of anion breakthrough curve was steep because of the large selectivity coefficient, and ion exchange rates increased as temperature increased. The temperature effect decreased as the total volume was increased or as the resins were exhausted.

  • PDF

Numerical analysis of the hyporheic flow effect on solute transport in surface water (혼합대 흐름이 지표수 내 용질거동에 미치는 영향 수치모의 분석)

  • Kim, Jun Song
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.23-32
    • /
    • 2022
  • This paper performs two-dimensional numerical simulation of surface water-groundwater coupled flow and solute transport to investigate the effect of the hyporheic exchange at the sediment-water interface (SWI) on surface solute transport. For the impermeable bed case in the absence of hyporheic flow, the trapping effect of flow recirculation associated with the ripple bed controls the shape of breakthrough curves (BTCs). However, the permeable bed case with hyporheic flow stimulates the extended tailing of the BTCs more significantly due to the elevated concentration of the BTC tailing resulting from slow hyporheic velocity. Also, the increased bottom pressure at the SWI with an increase in surface velocity shortens the BTC tailing because of increasing hyporheic velocity. These results infer that hyporhiec flow is critically important in predicting solute residence times in surface water.

Determination of Adsorption Isotherm Parameters by Breakthrough Curves in Activated Carbon and Zeolite 13X Packed Bed (활성탄 및 제올라이트 13X를 충진한 흡착탑에서 파과곡선을 이용한 흡착등온식 상수의 결정)

  • Kang, Sung-Won;Min, Byung-Hoon;Suh, Sung-Sup
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.131-138
    • /
    • 2005
  • Freundlich isotherms and Toth isotherms were obtained for benzene adsorption on activated carbon and zeolite 13X in static experiments. Breakthrough curves of benzene were measured in adsorption bed packed with the same adsorbents. Relation between breakthrough times and partial pressure of benzene was analyzed and the Freundlich isotherm parameters were determined. Adsorption amount of benzene predicted by the analysis of breakthrough experimental results was relatively consistent with that predicted by the static experimental results. Dynamic experiments for activated carbon bed, where more symmetric breakthrough curves were obtained, produced smaller errors with zeolite bed.

Sorption Analysis of Carbon Dioxide onto Cesium Carbonate (세슘카보네이트에서 이산화탄소의 수착반응)

  • Son, Young-Sik;Kim, Seong-Soo;park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.373-379
    • /
    • 2009
  • Cesium carbonate was used as an adsorbent to capture carbon dioxide from gaseous stream of carbon dioxide, nitrogen, and moisture in a fixed-bed to obtain the breakthrough data of $CO_2$. The deactivation model in the non-catalytic heterogeneous reaction systems is used to analyze the sorption kinetics among carbon dioxide, carbonate, and moisture using the experimental breakthrough data. The experimental breakthrough data are fitted very well to the deactivation model than the adsorption isotherm models in the literature.

Simultaneous Removal of Cd & Cr(VI) by Fe-loaded Zeolite in Column System (Fe-loaded zeolite를 이용한 칼럼 실험에서의 Cd & Cr(VI) 동시제거 반응성 평가)

  • Lee Ah-Ra;Lee Seung-Hak;Park Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • Laboratory column experiment for simultaneous removal of Cd and Cr(VI) were conducted using newly developed material of Fe-loaded zeolite having both reduction ability and sorption capacity. The solution containing Cd and Cr(VI) was injected into the column and the breakthrough curves (BTCs) for the contaminants were observed at the effluent port. Cd breakthrough was not initialized until Cr(VI) breakthrough was completed. Therefore it could be concluded that overall efficiency of Fe-loaded zeolite should be determined by the reactivity for Cr(VI). The relative concentration of Cr(VI) BTC increased to the unit value while initial breakthrough was delayed and the propagation of breakthrough was slowed. In order to quantitatively describe the shape of Cr(VI) BTC, new parameters of ${\alpha}\;and\;{\beta}$ designated to be shape parameters, were defined and applied in contaminant transport concentration. These parameters were employed to represent the degree of initial breakthrough delay and the degree of breakthrough propagation, respectively. As initial contaminant concentration increased, ${\alpha}$ decreased, which indicated the delay of BTC's initiation. And as initial contaminant flow rate increased, ${\beta}$ decreased, which represented the faster propagation of the BTC. From these results, Fe-loaded zeolite was found to be an effective reactive material for PRBs against heavy metals having different ionic forms in groundwater. And it could be expected that as groundwater flows faster, the propagation of breakthrough would be faster and as contaminant concentration is higher, the initial point of breakthrough would appear earlier.

페인트 부스에 발생하는 VOC 가스의 활성탄에 의한 흡착 제거특성

  • 김민경;김정두;이동환;감상규;이민규
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11b
    • /
    • pp.179-180
    • /
    • 2003
  • 자동차 도장 작업 시 배출되는 대표적인 용매물질인 부틸아세테이트, n-부탄올 및 톨루엔을 대상기체로 하여 활성탄에 의한 흡착 특성을 연구결과는 다음과 같았다. 처리대상가스의 유입농도가 증가할수록 파과시간은 점점 감소하였으며. 파과곡선의 기울기 또한 급격해졌다. 유량이 증가할수록 파과시간은 감소하였다.

  • PDF

Transport behavior of a surfactant tracer(CPC) with Langmuir type adsorption isotherm on NAPL-water interface in a homogeneous porous medium (NAPL-물 계면에서 Langmuir형 흡착특성을 보이는 계면추적자(CPC)의 다공성 균질매질내 유동특성)

  • 김헌기;문희수;이상훈
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.3-13
    • /
    • 2001
  • It has been known that nonlinear characteristics of sorption affect the transport behavior of water soluble pollutants in soils. However detailed experimental studies have not been performed to verify the effect of non-linearity of adsorption isotherm on transport of chemicals in porous media. In this research, the distortion of breakthrough curves of a cationic surfactant (cetylpyridinium chloride, CPC) in a engineered stainless steel column packed with glass beads were investigated. Glass beads with about 110 $\mu\textrm{m}$diameter coated with a thin n-decane film were used as the media providing the sorption surface for CPC. The CPC adsorption isotherm on the surface of n-decane from aqueous solution was a typical Langmuir type. The breakthrough curve of CPC using step Input showed a late breakthrough on the front side and early breakthrough on the back side accordance to the shape of the isotherm. The retardation factor of CPC was found to be a strong function of the input concentration, which also a manifestation of the non-linearity of the isotherm. The retardation factors for the CPC with step input agreed with those of pulse input that the maximum concentrations are controlled to be the same as the step input concentrations. This results support the validity of the unproven field practices of using hydrogeotracers with non-linear adsorption isotherms to determine the hydrogeological parameters, e.g., NAPL saturation, air-water or NAPL-water interfacial areas.

  • PDF

Modeling Study on Nuclide Transport in Ocean - an Ocean Compartment Model (해양에서의 핵종이동 모델링 - 해양구획 모델)

  • Lee, Youn-Myoung;Suh, Kyung-Suk;Han, Kyong-Won
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.387-400
    • /
    • 1991
  • An ocean compartment model simulating transport of nuclides by advection due to ocean circulation and intertaction with suspended sediments is developed, by which concentration breakthrough curves of nuclides can be calculated as a function of time. Dividing ocean into arbitrary number of characteristic compartments and performing a balance of mass of nuclides in each ocean compartment, the governing equation for the concentration in the ocean is obtained and a solution by the numerical integration is obtained. The integration method is specially useful for general stiff systems. For transfer coefficients describing advective transport between adjacent compartments by ocean circulation, the ocean turnover time is calculated by a two-dimensional numerical ocean model. To exemplify the compartment model, a reference case calculation for breakthrough curves of three nuclides in low-level radioactive wastes, Tc-99, Cs-137, and Pu-238 released from hypothetical repository under the seabed is carried out with five ocean compartments. Sensitivity analysis studies for some parameters to the concentration breakthrough curves are also made, which indicates that parameters such as ocean turnover time and ocean water volume of compartments have an important effect on the breakthrough curves.

  • PDF

Analysis of Solute Transport based on Electrical Resistance Measurements from Laboratory Column Tests (전기저항센서가 부착된 주상실험기에서 측정된 전기저항값을 이용한 용질의 이동해석)

  • Kim, Yong-Sung;Kim, Jae-Jin;Park, Junboum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.231-238
    • /
    • 2008
  • A column testing device capable of measuring the electrical resistivity of soil at 3 different locations was developed to verify applicability of bulk electrical conductivity (BEC) breakthrough curves in monitoring contaminant transport. Tracer injection tests were conducted with three different types of saturated sands to obtain average linear velocities and longitudinal hydrodynamic dispersion coefficients based on BEC breakthrough curves and effluent solute breakthrough curves. Comparative analysis of transport parameters obtained from curve fitting the results into the analytical solutions confirmed the validity of resistance measurements in estimating time-continuous resident solute concentration. Under the assumption that a linear relationship exists between ${\sigma}_{sat}-{\sigma}_w-C$, the BEC breakthrough curves are able to effectively reduce the laborious and time-consuming processes involved in the conventional method of sampling and analysis. In order to reduce possible uncertainties in analyzing the BEC breakthrough curves, it was recommended that resistance measurements take place nearby the effluent boundary. In addition, a sufficient electrical contrast or difference in the electrical conductivity of the influent and the saturating solution is required to conduct reliable analysis.

Adsorption Analysis of Benzene Vapor in a Fixed-Bed of Granular Activated Carbon (활성탄 충전층에서 벤젠 증기의 흡착특성)

  • Kim, Seong-Soo;Kim, Jong-Hyun;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.495-500
    • /
    • 2009
  • Activated carbon was used as an adsorbent to capture benzene vapor from gaseous stream of nitrogen in a fixed-bed to obtain the breakthrough data. The deactivation model is used to analyze the adsorption kinetics of benzene vapor using the experimental breakthrough data. The experimental breakthrough data are fitted very well to the deactivation model than the adsorption isotherm models in the literature.