• Title/Summary/Keyword: 튜브 배열

Search Result 75, Processing Time 0.038 seconds

Effect on Thermal Performance of Superheater Module under Part Load Operation in HRSG (배열회수보일러의 부분부하 운전에 따른 유동불균일이 과열기의 성능에 미치는 영향)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.161-166
    • /
    • 2008
  • The purpose of this study is to apprehend the behavior of exhaust gas flow from gas turbine during part load operation in Heat Recovery Steam Generator. As a first step of this work, internal flow characteristics according to HRSG types were examined by CFD analysis. Next step, tube temperature according to gas turbine 53% and 100% load conditions were calculated by results of CFD and those were compared with temperature data gathered from real plant. Finally, thermal performance due to part load operation was calculated to estimate the influence of heat transfer in superheater. In addition, new type of device is suggested to eliminate the uneven temperature distribution of tubes during part load operation.

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.

The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor (액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향)

  • Nam Ho Yun;Kim Jong Man;Choi Jong Hyeun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF

Etching treatment of vertically aligned carbon nanotubes for the application to biosensor (바이오센서로의 응용을 위한 수직 배열된 탄소나노튜브의 식각처리)

  • Jung, Seoung-Ho;Choi, Eun-Chang;Park, Yong-Seob;Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.353-353
    • /
    • 2007
  • 탄소나노튜브(CNT)의 tip 부분에 존재하는 금속 촉매 입자들은 불순물로써 나노전자소자에 응용하는데 좋지 않은 영향을 미칠 수 있다. 또한, 바이오센서에서 target 바이오 물질과 반응하는 물질을 CNT에 고정시키기 위해서는 CNT-tip을 개방시키는 것이 중요하다. 본 연구에서는 성장된 CNT의 tip부분에 존재하는 금속 촉매 입자의 제거와 CNT-tip을 개방하기 위해 $HNO_3$의 농도 (20, 40, 60)와 etching 시간 (5, 10, 15, 20, 25 min)에 따라 최적의 조건을 찾는 실험을 하였다.

  • PDF

Numerical Study on Heat Transfer Performance of Crossflow Fin-tube Heat Exchanger Depending on Different Fan Positions (직교류 핀-튜브형 열교환기에서 팬 위치변화에 따른 열전달 성능변화 연구)

  • Kim, Won Hyung;Park, Tae Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • The convective heat transfer of a crossflow fin-tube heat exchanger was studied numerically. In order to investigate the dependence of the heat transfer performance on the fan position, several cases with different blowing and suction types were selected for the fan position. A staggered tube arrangement was used for the heat exchanger, and the temperatures of the tube wall and air were $50^{\circ}C$ and $30^{\circ}C$, respectively. The three-dimensional flow structures were examined based on the results. In addition, the convective heat transfer coefficient and mean temperature difference between the inlet and outlet of the heat exchanger were analyzed for the various fan positions, and the heat transfer performance was investigated

A Study on the Curation Factors through Reverse Engineering Design of YouTube Algorithm - Focusing on Gender Keyword Search (유튜브 알고리즘의 역공학설계를 통한 큐레이션 요인 연구 - 성별 키워드 검색을 중심으로)

  • Bae, Seung-Ju;Lee, Sang-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.133-146
    • /
    • 2022
  • Despite the fact that Internet users around the world watch YouTube every day, very few users accurately recognize the recommendation algorithm for search results, and Google and YouTube are not disclosing it. Researchers tried to explore the undisclosed algorithm of YouTube in a reverse engineering design method, find key factors, and check the logical structure in which media platform operators recommend keyword search results and arrange them on the screen. Therefore, researchers studied the basic content priority factors through several months of discussion and data collection, and tried to reverse engineer the influencing factors based on the recommendation results according to male and female gender among the collected keyword search results. Although researchers' design only analyzed some of the almost infinite level of data uploaded and viewed for more than hundreds of hours every hour, these exploratory attempts will study media platform algorithms in the future, understand the intentions of operators, and protect users. thought it could be done.

Noise Prediction of HRSG for Gas Turbine (복합발전용 배열회수보일러의 소음예측)

  • 남경훈;박석호;김백영;김원일
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1116-1122
    • /
    • 1999
  • HRSG, which is one of main components of the combined cycle power plant,is composed of an inlet duct, a main body and casing, an outlet duct and a stack. It is important to design HRSG wihtin the allowable noise limit. For this purpose, it is necessary to analyze and predict the noise reduction and radiation at HRSG. In this paper, the technology for the noise prediction at each part of HRSG has been based on the empirical and field data, and also the HRSG noise prediction program has been developed. In order to verify the developed technology and program a field test is conducted. The results of noise prediction show good agreement with the measured.

  • PDF

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.

The Convective Heat Transfer for the Flow Perpendicular to the Tube Array (튜브배열 방향과 수직한 유동에 의한 관외 대류 열전달)

  • Jeon Yong-Han;Kim Jong-Yoon;Kim Nam-Jin;Kim Chong-Bo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.656-663
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the flow has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mean Nusselt number of the former was greater than that of the latter. It is verified that the results obtained by using the simulation show the same tendency with those of experiment.