• Title/Summary/Keyword: 투수기

Search Result 169, Processing Time 0.035 seconds

Groundwater Flow Modeling for a Finite Unconfined Sandy Aquifer in a Laboratory Scale (사질 자유면 대수층 모형에서의 지하수 모델링)

  • 이승섭;김정석;김동주
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.188-193
    • /
    • 1999
  • Transport of pollutants in aquifer largely depends on groundwater flow which is governed by aquifer hydraulic parameters. Determination of these parameters and associated groundwater modeling become essential for adequate remediation of contaminate groundwater. The objective of this paper is to analyze groundwater flow and determine the optimum hydraulic parameters by performing groundwater modeling based on sensitivity analysis for unconfined sandy gavel aquifer constructed in a laboratory scale under various boundary condition. Results revealed that the simulated drawdown was lower than the observed drawdown irrespective of boundary conditions. and specific yield (S$_{y}$) had less effect on the grondwater flow than permeability (K) in the aquifer. Water balance analysis showed that the measured drawdown in neighboring observation wells during pumping was higher than either simulated or recovered water table. The indicated that a difference might exist in the water tables between aquifer and wells. The difference was investigated by time domain reflectometry (TDR) measurements on water contents in the region of water table and capillary fringe, and explained by a delayed response of water table during gravitational drainage as the water table was lowered as a result of pumping.g.

  • PDF

Influence of Progressive Consolidation on Consolidation Behavior of Normally Consolidated Clayey Soil with Vertical Drains (연직배수재가 설치된 정규압밀 점성토 지반의 점진적 압밀이 차후 압밀거동에 미치는 영향)

  • Yune Chan-Young;Chung Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.5-18
    • /
    • 2005
  • In this study, the influence of progressive consolidation from the drainage boundary on the subsequent process of consolidation was investigated. Analytical theory and numerical program f3r consolidation of clayey soil were developed based on finite difference method, in which spatial variation of permeability and volume compressibility were implemented. And model ground with normally consolidated clayey soils and a vertical drain at its center were simulated. Various types of soils with different relations between coefficient of volume compressibility and permeability and void ratio were applied. Also numerical simulations based on the properties of the normally consolidated clay at Nakdong River basin and reconstituted kaolinite soil were performed to recognize its practical impact. Consequently, it is found out that retardation of consolidation induced by progressive consolidation is very important to understand consolidation behavior on field conditions and its effect is remarkable at the initial state of consolidation, and increases with plasticity index and applied load.

Laboratory Assessment of Geotextile Tube for Dewatering High Water Content Material (고함수비물질의 탈수에 대한 지오텍스타일 튜브의 실험적 평가)

  • Mo, Xinghua;Kim Tae-Hyung;Moo-Young. Horace K
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.261-269
    • /
    • 2002
  • The objectives of this paper are to study the use of geotextile tribes for dewatering high water content sludges and sediments and to evaluate their feasibility and affecting fsctors. To accomplish these objectives, pressure filtration tests were conducted on woven geotextile (Geotex$\circledR$ 46T and 1212T) fir high water content materials with a modified experimental apparatus. Test results indicate that 1) the filter cake formed on the inside of the geotextile tube is the major contributor to the retention of fine particles, but also causes a decrease in permeability, 2) controlling the formation of the filter cake and thus achieving a balance between soil retention and permeability is vital to a successful project, and 3) geotextiles, sludge properties, and filtration pressures have some effects on the dewatering efficiency and dewatering rate.

A Study on Application of Warm-Mix Quiet Pavement Using Fine-Size Aggregate (소입경 골재를 이용한 중온 저소음 아스팔트 포장의 적용 연구)

  • Jo, Shinhaeng;Baek, Yujin;Kim, Nakseok
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.56-64
    • /
    • 2013
  • The study examines the quiet pavement using fine-size aggregates and warm-mix technique to reduce traffic noise. In order to evaluate the quality of pavement, mix design and laboratory tests were carried out. Test results showed that using 10mm aggregates can reduce the cantabro loss compared with 13mm aggregates due to increase contact area between aggregates. Mixing and compaction temperatures of warm mix quiet pavement should be determined by gyratory compactor test because it is used high viscosity asphalt binder. Using warm-mix additive could reduce compaction temperature by about $15^{\circ}C$. Noise measurement and permeability tests were conducted at the test road for evaluation of the field performance. All of quiet pavements meet the standard of permeability and have sufficient porosity. Noise reduction of the quiet pavement using fine-size aggregates is more effective than that using 13mm aggregates. In particular, the effect of noise reduction was noticeable at low speeds.

The Stability Evaluation of River Embankment for a Piping Phenomenon (하천제방의 세굴에 대한 안정성 연구)

  • Lee, Song;Park, Hyung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.175-181
    • /
    • 2003
  • In this reseach, a seepage test is carried out for three kinds of soil using a upward seepage equipment. Reliability about the existing method of pipining investigation were verified making an estimate of the critical velocity, the critical hydraulic gradient, and hydraulic conductivity and so on. Also, sensitive analyses were carried out using Plaxis that is FEM Program about design factors of scour. The height of core had a big infulence on the hydraulic gradient of the embankment's lower part in the result of sensitive anaylsis. Also, second only to the height of core, and the slope of embankment, the width of crest had influence on scour. However, the change of hydraulic gradient in the effluent gateway had a little influence on the crest width of core. Using these results of sensitive analysis on designing, hydraulic gradient in the effluence gateway turned out to be reducing by altering design factors that change of sensitiveness is big, in case of the hydraulic gradient bigger than the standard hydraulic gradient.

Numerical Discussion on Natural Convection in Soils (지반내 자연대류에 대한 수치해석적 논의)

  • Shin, Hosung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.2
    • /
    • pp.35-47
    • /
    • 2017
  • Thermal behavior of soils is mainly focused on thermal conduction, and the study of natural convection is very limited. Increase of soil temperature causes natural convection due to buoyancy from density change of pore water. The limitations of the analysis using fluid dynamics for natural convection in the porous media is discussed and a new numerical analysis is presented for natural convection in porous media using THM governing equations fully coupled in the macroscopic view. Numerical experiments for thermal probe show increase in the uncertainty of thermal conductivity estimated without considering natural convection, and suggest appropriate experimental procedures to minimize errors between analytical model and numerical results. Burial of submarine power cable should not exceed the temperature changes of $2^{\circ}C$ at the depth of 0.2 m under the seabed, but numerical analysis for high permeable ground exceeds this criterion. Temperature and THM properties of the seafloor are important design factors for the burial of power cable, and in this case effects of natural convection should be considered. Especially, in the presence of heat sources in soils with high permeability, natural convection due to the variation of density of pore water should be considered as an important heat transfer mechanism.

Comparison of runoff characteristics before urbanization in Pangyo new town using CAT and HEC-HMS (CAT모형과 HEC-HMS를 이용한 판교 신도시 개발 전 유출 특성 비교)

  • Choi, Shinwoo;Kim, Hyeonjun;Jang, Cheolhee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.168-168
    • /
    • 2016
  • 도시화는 수문학적으로 산림이나 농경지와 같은 투수지역을 건물, 도로 등의 불투수 지역으로 변화시키는 것이며, 이로 인하여 홍수파의 도달시간이 줄어들고 첨두유량이 증가하는 등의 수문변화를 수반하게 된다. 도로나 건물 등이 대부분을 차지하고 있는 도시지역에서는 지표면이나 식생으로부터 대기 중으로 방출되는 증발산량이 농촌이나 산림지역보다 상대적으로 적으며, 강우시 토양중의 침투량과 지표면의 저류량도 도시지역에서는 매우 적게 나타난다. 도시화 전 후의 물순환특성을 평가하기 위해서는 도시 개발 전 후의 장단기 수문 관측 결과를 기초로 물순환계를 구성하는 인자간의 관계를 정량적으로 분석하고 물순환계 구성요소의 일부 변화가 다른 부분에 미치는 영향을 평가할 필요가 있다. 즉, 도시화가 물순환 구조 변동에 미치는 영향을 정량적으로 평가함으로써 유역 전체의 건전한 물순환 체계를 유지할 수 있는 대책 수립이 가능하다. 본 연구에서는 판교신도시 개발에 따른 유역에서의 홍수 및 유출특성 변화의 정량적 규명을 목적으로 두고 집중형 모형인 HEC-HMS모형과 물리적 기반의 준분포형 모형인 CAT을 이용하여 판교신도시 개발전의 정량적 물순환 특성을 평가하였다. 대상유역은 지방 2급 하천 탄천의 지류인 운중천, 금토천이 포함된 판교유역이며, 유역면적은 약 $25km^2$이다. 이 중 유역면적의 38 %에 해당하는 지역이 개발되었으며 개발된 지역은 하류부근에 위치한다. 강우자료는 지상 강우관측소인 수원 관측소의 지점강우 자료를 이용하였다. 도시 개발 전 단계에 해당하는 2006년, 2007년 호우사상 중 누적강우량 50 mm 이상인 호우사상을 추출하여 모의를 수행하였다. 유출 특성 분석을 위해 12개의 소유역과 5개의 하도로 구성하였으며 HEC-HMS의 손실량 산정방법으로는 SCS Curve Number법을 사용하였고, 단위도는 Clark 단위 도법을 적용하였다. CAT모형에서 침투는 Rainfall Excess방법, 하도추적은 Muskingum 방법을 적용하였다. 관측치와 모의치의 적합도 검증을 위해 RMSE (Root Mean Square Error), NSE (Nash Sutcliffe Efficiency), $R^2$값을 산정하여 비교 분석하였다.

  • PDF

Characteristics of Hydaulic Conductivity in Middle-Jeju watershed (제주도 중제주유역의 수리전도도 특성)

  • Kim, Min-Chul;Yang, Sung-Kee;Lee, Jun-Ho;Yang, Won-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.386-386
    • /
    • 2017
  • 지하수 해석을 위해 3차원 수치해석 모형이 적용되고 있으나, 다양한 매개변수를 명확히 적용하기에는 한계가 있다. 특히, 수리전도도는 지층의 투수성정도를 나타내는 계수로 지하수 분석에 매우 중요한 매개변수이다. 신뢰성의 확보를 위해 양수시험을 통해 산출된 결과를 이용하고 있으나 소수관정의 시험결과를 유역의 대푯값으로 적용하기에 불확실도가 매우 높고, 수위변화가 독특한 지역의 정확한 수리특성을 적용하기에 한계가 있다. 이 연구에서는 수리전도도 특성을 해석하기 위하여 3차원 수치해석모형을 적용하였으며, 모델보정 방법 중 Regularization(정규화)라고 불리는 Pilot point 기법을 사용하였다. 제주도와 같이 수리전도도 값이 지역별로 차이가 크고 동일 유역 내에도 다른 지질구조를 보이는 등 동일 매질에서 동일 투수성을 보이지 않는 다양함으로 실측값들을 적용하기에 어려운 곳에서 정규화라는 보정방법은 최적화된 방법이다. 지하수위는 중제주유역 내 위치한 12개소 수위관측정의 2016년 연평균수위를 적용하였다. 미계측지역은 제주도 등수위선자료를 이용하여 DEM을 구축하였으며, 임의지점 17개소를 선정하여 대표수위로 적용하였다. 중제주유역의 평균 수리전도도는 82.90 m/day로 분석되었으며, 유역의 동측 하류부는 최대 1,745 m/day로 비교적 큰 결과가 산출되었다. 유역의 중앙에 위치하는 OR관측정을 기준으로 동 서지역의 지하수위를 검토한 결과 서측은 지형구배에 따라 지하수위가 형성하고 있으나, 동측의 경우 상 하류의 표고차가 30m이상 발생되지만 지하수위는 유사한 형태를 보이고 있다. 지하수 흐름에 해석되는 Darcy의 방정식은 수리전도도와 동수경사는 반비례관계를 나타내며, 이 이론에 의해 상 하류 지하수위가 유사하게 형성되는 동측지역은 국부적으로 수리전도도가 높게 형성되는 것으로 확인되었다. 실무에서는 유역경계에 따라 평균화된 매개변수가 적용되므로 명확한 지하수 해석이 어렵고, 수리전도도와 같이 지역적 편차가 심한 매개변수는 다양한 연구를 통해 적용성검토가 수행되어야 한다.

  • PDF

Analysis of Urban Runoff Reduction according to SSP Climate Change Scenarios Applying LID Element Technology : focus on the Cheonggyecheon Basin (LID 요소기술을 적용한 SSP 기후변화 시나리오에 따른 도시 유출량 저감 분석_청계천유역을 대상으로)

  • Eui Hyeok Yoon;Bae Sung Lee;Sang Yeon Yoo;Min Ho Lee;Ye Chan Shin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.386-386
    • /
    • 2023
  • 본 연구는 청계천 유역에 대하여 미래 저영향개발을 고려한 도시 수문순환 변화를 전망하였다. 새로운 기후변화 시나리오에 대하여 유출량 변화 특성 및 저영향개발 요소기술의 적용을 통하여 유출량 감소 변화를 분석하기 위하여 18개의 GCM을 선정하였고, 이를 통하여 생산된 강수량 자료를 활용하였다. 그리고 기후변화 시나리오의 새로운 개념인 SSP 시나리오를 적용하였다. SSP2-4.5 및 SSP5-8.5 시나리오에 대하여 2046년~2075년 기간에 대한 강수량의 변화는 현재 대비 SSP2-4.5 시나리오에서 13.9%와 SSP5-8.5 시나리오에서 20.6%의 증가가 전망되었다. 그리고 미래 기간에 대하여 저영향개발을 고려하여 SWMM을 이용하여 유출량의 저감 변화를 모의하였다. 그 결과 GCM별 또는 저영향개발 요소기술의 조합에 따라 유출량 저감 차이는 있으나 투수성포장 및 침투도랑을 유역 전체에 적용했을 경우 가장 효과가 좋았다. 그 효과는 투수성포장은 SSP2-4.5 시나리오에서는 14.2%, SSP5-8.5 시나리오에서는 13.5%의 유출량 저감 효과를 나타내었고, 침투도랑은 SSP2-4.5에서 14.0%, SSP5-8.5에서 14.2%씩 유출량이 저감되는 것으로 분석되었다. 이 연구는 약 10년 이상 소요되는 도시 수문순환 계획의 이행을 고려하여, 앞으로 20년 후의 기후에 대한 도시 수문순환의 변환을 전망하였다. 그러므로 향후 우리나라 수도 서울의 도시 수문순환 등의 지속가능성 확보에 기여 할 수 있을 것으로 판단된다.

  • PDF

Assessment of Flood Mitigation Policy in Urban Watershed using Climate Change Scenarios (기후변화 시나리오를 이용한 도시유역의 홍수 대응 정책 평가)

  • Hee Won Jee;Seung Beom Seo;Jiheun Kim;Jaepil Cho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.498-498
    • /
    • 2023
  • 정부와 지자체는 기후변화로 인한 홍수 피해를 저감하고자 내수배제 용량 증대, 건전한 물환경 조성 등 다양한 방향의 정책들을 제시하고 있다. 각 지자체 별로 다양한 홍수 대응 정책들을 반영하고 있지만, 2022년 집중호우에 의한 도심지역 침수 피해 사례와 같이 기후변화로 인하여 증가된 홍수량에 대한 적절한 대비를 못하고 있다. 따라서 지자체는 현재의 홍수 대응 정책들과 더불어 추가적인 홍수 대응 정책을 시행하여야 하며, 지속가능한 개발을 고려한 유역의 건전한 물순환을 유지해야 한다. 본 연구에서는 토지피복 등 유역의 특성을 고려하여 실행 가능한 홍수 정책들의 대응 효과를 분석하고, 기후변화 시나리오를 반영한 미래 빈도분석 결과를 반영하여 최적의 홍수 대응 정책 대안을 제시하고자 한다. 연구에서 선정한 홍수 대응 정책은 우수관거 용량을 증대시키는 관거 교체 정책, 지속가능한 저영향개발 기법을 적용한 투수성 포장과 옥상녹화 정책을 선정하였다. 미래 강우 시나리오는 3개의 CMIP6 GCM모형(ACCESS-CM2, CanESM5, GFDL-ESM4)과 2개의 SSP-RCP 시나리오(SSP1-26, SSP5-85)를 사용하였다. 홍수 저감 효과는 도시유출해석모형인 SWMM 모형으로 분석하였다. 또한, 정책 이행에 발생하는 공사와 운영 비용을 산정하여 경제적 편익 분석을 실시하였다. 분석 결과, 투수성 포장과 우수관거 용량 확대 정책을 반영하는 정책 시나리오가 가장 경제적인 홍수 저감 효과를 가져오는 것으로 분석되었다. 본 연구의 정책별 경제적 비용과 홍수 저감 효과 분석은 기후변화에 대비한 도시유역의 홍수 대응 정책을 평가하고 우선순위를 선정하는데 있어 기여 할 수 있을 것으로 기대된다.

  • PDF