• Title/Summary/Keyword: 투명교정장치

Search Result 16, Processing Time 0.024 seconds

Analysis of Mechanical Properties of Polymer Material for Clear Aligner using Uniaxial Tensile Test (일축인장시험을 통한 투명교정장치용 고분자 소재의 역학적 특성 분석)

  • Jeong, Ji-Young;Je, Tae-Jin;Jeon, Eun-chae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.64-69
    • /
    • 2018
  • Clear aligners are popular in the field of dental orthodontic treatment because they offer a discreet alternative to braces due to their use of transparent materials. They are formed from flat transparent polymer materials by hot pressed molding. It is necessary to know the mechanical properties of the polymer materials to be able to form the exact shapes of the clear aligners. However, this information is not publicly available. In this study, we present a method to reliably measure the mechanical properties of clear aligner polymer materials and analyze the factors effecting these mechanical properties. First, we surveyed standards related to the mechanical properties of polymer materials to obtain reliable data. Consequently, ISO 527 was selected for use in this study because of the size and thickness of the flat transparent polymer material. The uniaxial tensile tester was constructed and it was verified whether displacement of a crosshead could be regarded as a displacement of gauge-length by optical analysis. Uniaxial tensile tests of three thicknesses from three different companies were performed and each engineering stress-strain curve was measured. Tensile strengths and elastic moduli were obtained by analysis of the stress-strain curves. The tensile strength and elastic modulus of ISO 527 was found to be approximately 50MPa and 2.3GPa, respectively. Both values showed material and thickness dependency.

Diagnosis and Treatment of Malocclusions using the Invisalign System (인비절라인 시스템을 이용한 부정교합의 진단 및 치료)

  • Kim, Hyungsoo;Ahn, Jae-Hyun;Boyd, Robert L.
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.21-29
    • /
    • 2003
  • Recent developments in software technology have made it possible to create a virtual three-dimensional model of the dental arches from digitally scanned casts of a patient's dentition. This modelmay then be manipulated with software to produce stages of tooth movement from the initial malocclusion to the final desired occlusion. A sterolithograghic model is made for each stage of tooth movement which is the basis for construction of a series of clear and thin overlay appliances. These appliances are worn full time by the patient to move the teeth according to the programmed stages of movement. Malocclusions involving mild to moderate crowding and space closure have been proven to be successfully treated with this appliance. Experience with this appliance has demonstrated excellent patient compliance with less discomfort, improved esthetics and oral hygiene control, when compared with fixed orthodontic appliances. Orthodontic treatment with this appliance is a potentially useful alternative approach to fixed appliances for treatment of a variety of malocclusions in patients with fully erupted permanent teeth.

The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties (교정용 열가소성 재료의 두께와 변형량이 재료의 물리적 특성에 미치는 영향)

  • Min, Sam;Hwang, Chung-Ju;Yu, Hyung-Seog;Lee, Sang-Bae;Cha, Jung-Yul
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.16-26
    • /
    • 2010
  • Objective: The purposes of this study were to evaluate the force and stress depending on the type, deflection and thickness of the materials and to evaluate the mechanical properties of thermoplastic materials after repeated loading. Methods: Four types of thermoplastic products were tested. Force until the deflections of 2.0 mm and the stress when the materials were restoring to its resting position were evaluated. The mechanical properties of thermoplastic materials evaluated after 5 repeated loading cycles. Results: The interaction was observed between the thickness and the deflection (p < 0.05) from the regression equation. Thickness and amount of deflection rather than products and materials showed the largest effect on force and stress. In all products, at least 159 gf of force was required for more than 1.0 mm deflection or when materials with 1.0 mm thickness were deflected. The stress recorded was more than 19 gf/$mm^2$. During repeated loading, each group showed significant difference on the force and the stress (p < 0.01), 10 - 17% reduction of force and 4 - 7% reduction of stress in average. Conclusions: Proper thickness of thermoplastic materials and deflection level of tooth movement should be decided for the physiologic tooth movement. Force decay after repeated loading should be considered for the efficient tooth movement.

Clinical limitations and its solutions of the clear overlay appliance treatment (투명교정장치의 임상적 한계와 그 해결)

  • Bae, Gi-Sun
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.563-574
    • /
    • 2016
  • A clear overlay appliance is a type of a removable appliance made from transparent thermoplastic plastic film that covers the entire dentition to move the teeth. It is one of the most favored orthodontic methods opted for by adult patients; this treatment is esthetic, does not cause discomfort and allows oral hygiene to be easily managed when compared to other conventional fixed treatment methods. However, the use of clear overlay appliances, such as invisalign or clear aligner, is associated with various clinical challenges. In particular, the appliances require longer treatment periods compared to fixed treatment, and due to the structural characteristics of the appliances, it is difficult to make proper posterior occlusion and certain type of tooth movement, including extrusion, rotation and tip. Thus, the clear overlay appliances are regarded as supplementary appliances by most orthodontists and have been used for simple orthodontic treatments, such as partial anterior alignments or orthodontic relapse cases. Owing to the remarkable advancement in the field of 3D digital technology over a period of 15 years, the accuracy and convenience of modern clear overlay appliances have continuously improved. Moreover, orthodontic outcomes have also been greatly improved by the introduction of new materials and successful application of various biomechanical methods from conventional orthodontic treatments in the design of clear overlay appliances. This study investigates the clinical limitations that should be considered during the application of clear overlay appliances and also examines the efforts and methods used to overcome these challenges.

  • PDF

Effects of bisphosphonate and indomethacin on alveolar bone remodeling in rats (Bisphosphonate와 Indomethacin이 백서 치조골의 골개조에 미치는 영향)

  • Cho, Myeong-Sook;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.163-174
    • /
    • 1996
  • The purpose of this study was to examine the effects of bisphosphonate and indomethacin, blockers of bone resorption with different mechanisms, on alveolar bone remodeling. Male rats were divided into control, bisphosphonate and indomethacin groups, and then each group was divided info an experimental side and a control side according to the force application. Bisphosphonate(6.3mg/kg,$2.52x10^{-2}mol/L$) and indomethacin (9mg/kg, $2.52x10^{-2}mol/L$) were injected 6 hours and 1 hour before or 24 hours after the force application. The rats were killed 72 hours after the force application and histologic examination was perfomed. The values of serum acid phosphatase and lactate dehydrogenase were also measured in the control md experimental groups treated with bisphosphonate or indomethacin 1 hour before the force application. In the experimental side, the least number of osteoclasts was noted in the groups treated 1 hour before the force application with indomethacin or bisphosphonate, while there were no differences between the control and the groups treated with drugs 6 hours before or 24 hours after the force application. In the control side, the number of osteoclasts was not inecreased with no differences among the groups. Histologic examination revealed a severe alveolar bone resorption in the control group and the groups treated with indomethacin 6 hours before or 24 hours after the force application. Indomethacin treatment 1 hour before the force application and bisphosphonate treatment at any time significantly attenuated the bone resorption. Electron microscopically, ruffled border and clear zone of osteoclasts were observed in the control and indomethacin groups, while some osteoclasts were detached from the bone surface and exhibited dull cellular projections in the bisphosphonate groups. The bisphosphonate and indomethacin groups showed lower values of acid phosphatase and lactate dehydrogenase than the control group. The acid phosphatase value in the bisphosphonate group was lower than that in the indomethacin group, whereas there was no difference in the lactate dehydrogenase value between the groups. These results suggest that bisphosphonate reduces the activity of osteoclasts as well as the number of osteoclasts and that indomethacin reduces the number of osteoclasts without affecting the activity of osteoclasts. Bisphosphonate has a larger inhibitory effect on bone resorption md thus less limitation in the application time than indomethacin.

  • PDF

TREATMENT OF IMPACTED MANDIBULAR FIRST MOLAR BY SURGICAL EXPOSURE : A CASE REPORT (매복된 하악 제1대구치의 외과적 노출술을 이용한 치험례)

  • Cho, Yun-Jung;Park, Young-Ok;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.322-328
    • /
    • 2007
  • The first molar is important for mastication and also it plays roles to formation of vertical occlusion and growth of jaw bone after mixed dentition. Impaction of mandibular first molar can result in a short lower facial height, formation of a follicular cyst, pericoronal inflammation, resorption of the roots of neighboring teeth and malocclusion. The options of treatment plans are as follows; observation, surgical exposure, orthodontic traction, surgical relocation and extraction. Surgical exposure could be considered as a basic treatment plan. For surgical exposure it is important to maintain patent channel between the crown and the normal eruptive path into the oral cavity, many techniques including cementation of a celluloid crown, packing with zinc oxide-eugenol surgical pack are used. In these cases, we could observe spontaneous eruption of mandibular first molar using surgical exposure with or without removal of odontoma. Also we could obtain the main patency effectively and conveniently by using surgical pack and translucent retainer.

  • PDF