Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography (유방촬영장치의 압박대 재질을 고려한 투과선량 평가)

  • Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.307-312
    • /
    • 2015
  • Mammography improves image quality that is on the increase day by day and get a picture with the pressure it is essential to reduce the dose. However, because due to the thickness of the cuff itself may increase the dose scattering lines is necessary study on the cuff material. Material that is currently being used in clinical Polycarbonate is a plastic and family. If you try to reduce the exposure of patients than itgie need to consider for the better material in this study to compare against a radiolucent line for amorphous plastic material of the plastic. results radiolucent and half layer, transmitting dose Pixel values HIPS, GPPS, ABS, Tritan, PC, PMMA showed high results in the net.

The Effect of Support Material of Ceramic MF Membrane on the Fouling and backwashing Efficiency (세라믹 정밀여과막의 지지체 재질이 막오염과 역세척 효율에 미치는 영향)

  • 김재홍;이호상;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.39-39
    • /
    • 1997
  • 김치산업에서 원재료의 염적공정중에 발생하는 폐염적수를 처리하여 염적공정에 재사용하는 새로운 시스템을 개발하였다. 관형 정밀여과막을 사용한 본 연구에서 막오염의 감소와 높은 막투과유속의 유지를 위하여 산역세척과 투과수역세척이 도입되었고 대상이 되었던 세공크기가 비슷한 4종류의 막(Carbosep M14, Membralox Z100, Membralox A200, Microdyne MD020TP 2N)에 대하여 역세척의 효율이 각각 다르게 나타났다. 특히 지르코니아 재질의 막 표면과 탄소재질의 지지체로 이루어진 Carbosep M14 세라믹막은 투과수역세척시에 역세척을 하지 않았을 때 보다 오히려 투과유속이 감소하는 특이한 현상이 관찰되었고 이러한 역세척 효율의 차이의 원인을 규명하기위한 연구가 진행되었다. 4종류의 막에 대하여 전처리된 폐염적수의 여과시 진행되는 막오염 메카니즘을 알아보기 위하여 문헌에서 잘 알려진 4가지의 여과모델식을 적용하여 보았고 직렬여과저항모델을 이용하여 여과저항을 세분하여 측정하였다. 모델식의 적용결과 역세척의 효율이 좋은 3종류의 막에는 막표면의 케이크형성이 주된 투과유속의 감소원인임을 알아내었고 carbosep M14 막은 용존유기물의 비가역적인 흡착과 세공막힘이 주된 원인임을 알 수 있었다.

  • PDF

The Study of Separation of VOC using PDMS Pervaporation membrane (PDMS투과증발막을 이용한 VOC의 분리에 관한 연구)

  • 송영석;김희진;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.127-128
    • /
    • 1997
  • 1. 서론 : 투과증발막에 의한 수용액으로부터 유기물을 선태적으로 투과하는 공정은 용제회수, 오염감소, 유기물농축 및 처리 등의 목적으로 사용되어진다. 1989년에 이르러 상업적으로 응용이 되기 시작하였으며, 여러가지 막재질이 개발되고 있으나 현재 적용되고 있는 막은 Silicone rubber가 주를 이루고 있다. 이중 PDMS 막은 유기물질의 선택적 분리에 있어서 가장 우수한 막재질로 보고되고 있다. 투과증발을 이용하여 휘발성 유기물질을 분리함에 있어서 그 분리능은 막재질의 선정뿐만 아니라 막구조의 결정이 중요한 변수로 지적되며, 이 구조에 따라 투과성능의 다양한 변화를 가져올 수 있다. 본 연구는 PDMS의 막구조를 달리하면서 제막하여, VOC중 MEK(Methyl Ethyl Keton)과 toluene을 실험물질로 정하여 PDMS막의 투과성능을 관찰해보았다.

  • PDF

The Characterization of Floc Formation Under Various Pre-coagulation Conditions (응집-막분리 공정 적용시 전처리 응집조건에 따른 용존성 유기물 상(相)변화 특성)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1139-1145
    • /
    • 2008
  • The objectives of this research are to investigate the mechanism of coagulation affecting UF and find out the optimum conditions of the combined of coagulation with UF membrane filtration for NOM removal. During the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation (both rapid mixing and slow mixing) improved dissolved removal efficiency. Also, for combined coagulation to membrane process, flux reduction rate showed lower than only UF process. The rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane.

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

막결합형 혐기성 소화에서 무기분리막과 유기분리막의 막오염 특성 비교

  • 강인중;윤성훈;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.51-51
    • /
    • 1995
  • 혐기성 미생물의 특징은 성장 속도가 느리고 침강성이 좋지 않다는 점이다. 이 문제의 한 해결책인 막결합형 혐기성 소화는 고액분리를 완전하게 수행함으로써 미생물의 유출을 방지하여 반응조 내부에 미생물을 고농도로 유지할 수 있을 뿐만 아니라 에너지의 회수와 설비 면적의 축소 등 많은 장점이 있다. 이 막결합형 혐기성 소화의 경제성은 사용된 분리막의 투과 속도에 의해 크게 좌우된다. 분리막의 투과 속도에 영향을 미치는 인자로는 미생물 및 유입수를 비롯한 반응조 내부의 상태, 막모듈 압력 온도 막면유속 등의 운전 조건이 있다. 또한 사용되는 분리막 자체의 재질도 투과 유속에 큰 영향을 미친다. 본 연구의 목적은 관형의 지르코니아 스킨층과 탄소 소재 지지층으로 이루어진 복합 재료 분리막과 폴리프로필렌 분리막을 이용하여 막재질에 따른 막오염 특성을 비교 분석하고 효과적인 투과율 회복 방법을 확립하는 것이다.

  • PDF

미세 다공성 무기질 막에 의한 투과증발법

  • 이용택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.03a
    • /
    • pp.91-109
    • /
    • 1996
  • 막에 의한 유기액체 혼합물을 분리 하는 방법으로 액/증기 계의 막투과 메카니즘으로 분리, 농축하는 투과증발법(Pervaporation)이 연구되어져 왔다. 이 방법은 공급상이 수용액, 투과상이 기체로써 상변화를 동반하는 과정이기 때문에 분리의 에너지 효율은 증류법에 비해 그다지 높게 기대 되지 않지만 공비점(azotropic point)을 가지는 혼합물이나 비점차가 적어 분해하기가 쉽고 증류법이 불가능한 혼합물의 분리에 많이 쓰여져 왔다. 그러나, 이 방법을 실용화 시키기 위해서는 분리계수 및 투과속도가 큰 막이 필요로 하며 현재 그 연구 개발에 박차를 가하고 있다. 본 강의는 무기재질을 가지는 다공성막을 사용하여 투과증발 분리법에 대한 최근의 연구 동향에 대해서 간략하게 서술하고자 한다.

  • PDF

A Study on the Compression paddle of meterials in Mammography (유방촬영장치에서 압박대 재질에 관한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.187-188
    • /
    • 2015
  • 유방촬영은 날로 증가추세에 있으며 압박을통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질 중 비결정 플라스틱에 대한 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

Polyethersulfone을 이용한 중공사막 제조시 내부응고제의 영향에 관한 고찰

  • 민병렬;조한욱;김상도
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.22-23
    • /
    • 1995
  • 한외여과막이 순수제조, 고분자물질의 분리, 폐수처리 등에 쓰이기 시작되면서, 높은 투과율, 내화학성, 충전밀도를 갖는 모듈이 요구되었다. 따라서 polysulfone(이하 PSf)을 막의 재질로 사용한 중공사형모듈이 주로 개발되었다. 그러나 본 연구에서는 PSf보다 투과율, 기계적 강도, 열적강도 및 화학적 성질 면에서 뛰어난 polythersulfone(이하 PES)을 막의 재질로 선택하였다. 또한, 지금까지는 수백 ${\AA}$에서 1mm정도의 외경(O.D.)을 갖는 중공사막이 개발되었다. 따라서 상당히 높은 충전밀도를 갖는 모듈은 개발되었으나, 점성이 높은 feed를 처리할 때, fouling이 큰 문제로 대두되었으며, 중공사막보다 외경이 큰 관형 막은 fouling에는 비교적 강하나, 충전밀도가 낮아서 단위부피당 flux가 낮은 단점을 갖고 있다. 따라서, 중공사막과 관형 막의 중간형태인 외경 2mm이상의 capillary membrane은 강한 fouling 저항과 비교적 높은 단위 부피당 투과율을 갖는다.

  • PDF

Effect of Membrane Materials on Membrane Fouling and Membrane Washing (막의 재질에 따른 막오염 특성 및 물리·화학적 세척의 영향)

  • Shim, Hyun-Sool;Jung, Chul-Woo;Son, Hee-Jong;Sohn, In-Shik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.500-505
    • /
    • 2007
  • The objectives of this research were to (1) identify the membrane fouling potential due to different fractions of NOM (2) correlate the physicochemical properties of NOM and membranes with the adsorption of humic substances on membrane (4) find out the effect of membrane physical and chemical washing according to membrane material. The static adsorption test and adsorption test showed that hydrophobic organics adsorbed much more quickly than hydrophilic organics. In case of the effect of membrane properties on the adsorption of organic fractions, the adsorption rate ratio(a) of hydrophobic membrane (0.016, 0.077) was greater than that of hydrophilic membrane (0.010, 0.033) regardless of the kind of organic fractions. This suggests that the UF membrane fouling were occurred mainly by internal pore size decreasing due to adsorption of organic into pore surface for hydrophobic membrane, and by sieving of organics and forming a gel layer on the membrane surface for hydrophilic membrane. In conclusion, the decrease in the pore volume, which was caused by the organic adsorption into the internal pore, was greater with the hydrophobic membrane than with the hydrophilic membrane. In case of the effect of membrane properties on permeate flux, the rate of flux decline for the hydrophobic membrane was significantly greater than that for the hydrophilic membrane.