• Title/Summary/Keyword: 투과제

Search Result 669, Processing Time 0.033 seconds

Pervaporation Separation Characteristics for Water-Ethanol Mixtures Using Porous Hollow Fiber PVA Composite Membranes (미세 다공성 중공사 PVA복합막을 이용한 에탄올 수용액의 투과증발분리 특성)

  • Kim, Ji Seon;Park, Hun Whee;Seo, Chang Hee;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.5
    • /
    • pp.360-366
    • /
    • 2013
  • The Poly (vinylidene fluoride) and poly (acrylonitrile) (PAN) hollow fiber composite membranes coated with poly (vinyl alcohol) (PVA) and poly (acrylic acid) (PAA) as the crosslinkig agent are prepared. The resulting membranes were characterized for aqueous 90 wt% ethanol solution by pervaporation techniques in terms of the permeability and separation factor. In general, as both the crsslinking reaction temperature and the crosslinking agent concentration increase, the permeability decrease while the separation factor tends to increase. And also the permeability increased and the separation factor decreased as the feed temperature increased. Typically, the permeability $502g/m^2hr$ at the feed temperature $70^{\circ}C$ was obtained for PVDF hollow fiber membrane prepared with the crosslinking agent PAA 3 wt% at the reaction temperature $60^{\circ}C$ whereas the separation factor 218 was shown for the membrane reacted with PAA 11 wt% and at $100^{\circ}C$ for the feed temperature $50^{\circ}C$.

Water Vapor Transmission for T800/AD6005 Based Composite Motor Case (T800/AD6005계 복합재 연소관의 습기 투과에 관한 연구)

  • 박명규;류백능;최영보;도영대
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.50-58
    • /
    • 1998
  • Water vapor transmission was tested in water bath controlled by $20^{\cire}C$, 90%RH for T800/AD6005 based composite motor case which made by filament winding method. We detected internal relative humidity of composite motor case by inserting the humidity detector through the head of motor case for the study of humidity transmission through the wall of composite motor case. We found out that this composite material appears the water vapor flux of 2.88${\times}$$10^{-9}$g/$\textrm{m}^2$sec and diffusivity of 7.98${\times}$$10^{-7}$$\textrm{mm}^2$/sec at $20^{\cire}C$, 90%RH water vapor condition.

  • PDF

Pwevaporation Separation of Aqueous Ethanol Solution Through Poly(vinyl alcohol) Membranes Crosslinked Poly(acrylic acid-co-maleic acid) (Poly(acrylic acid-co-maleic acid)로 가교된 Poly(vinyl alcohol)막을 이용한 에탄을 수용액의 투과증발분리 특성)

  • 남상용;성경수;천세원;임지원
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.255-261
    • /
    • 2002
  • Poly(vinyl alcohol) (PVA) membranes crosslinked with poly(acrylic acid-co-maleic anhydride) (PAM) as a polymeric crosslinking agent were prepared to investigate the pervaporation performance for the dehydration separation of aqueous ethanol solution. The characteristics of the resulting membranes crosslinked(x) were analysed by FT-IR and water swelling test. The water swelling decreased with increasing crosslinking agent content. The crosslinked PVA membranes with PAM showed lower water swelling than those of PVA membrane crosslinked with glutaraldehyde and modified PVA membrane. The swelling of water molecules in the crosslinked PVA membranes is more restricted by both chemical crosslinking between PVA and polymeric crosslinking agent chains and physical crosslinking by the entanglement between the PVA and polymeric crosslinking agent chains. For the pervaporation of aqueous ethanol solution through the crosslinked membrane, as the contents of crosslinking agent increased, the separation factor increased while the permeation flux decreased. The separation factor slightly decreased and permeation flux increased with increasing feed water content. As a result it could be considered that PVA-PAM membranes suppressed the plasticization effect even in the range of high water concentration in fled.

Effect of the Structure of the Smallest Poresize Layer on the Permeability of PES Microfiltration Membranes (최소 기공층 구조가 PES계 정밀여과막 투과 성능에 미치는 영향)

  • Kim, No-Won
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2009
  • PES (polyethersulfone) membranes with highly enhanced their asymmetry were prepared by phase inversion process. The membranes were prepared by using PES/DMF (N,N-dimethylformamide)/TSA (p-toluenesulfonic acid)/PVP (polyvinylpyrrolidone) casting solution and water coagulant. The pre-coagulation of membrane surface which was induced by an addition of TSA as a demixing agent and PVP as a swelling polymer in the PES solution and humid exposure time, played a crucial role in determining morphological properties and the PWP (pure water permeation) performance. The PES solution was coated on polyester film under condition of 80% humidity for a while ($72{\sim}144$ sec) before immersing in a coagulation bath. The characterization of membranes was carried out by a capillary flow porometer, a FE-SEM and a permeation test apparatus. As the thickness of the smallest pore size layer (SPL) decreased, the asymmetry of membrane increased under conditions of 20 wt% of TSA and 10 wt% of PVP in 11 wt% of PES solution during longer humid contact time. As a result, the membranes showed a remarkable increase of PWP.

The Estimating an Effect of Rapid Flux Increase to a Membrane in the Intermittent Aeration MBR Process Using Alum Treatment (응집제를 활용한 간헐포기 MBR공정에서 순간플럭스 증가가 분리막에 미치는 영향 평가)

  • Choi Song-Hyu;Cho Nam-un;Han Myong Su
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.70-83
    • /
    • 2005
  • By supplying air intermittently in various mode, the effects of oxic/anoxic time ratio and air scrubbing in aeration condition on the membrane flux and permeability were investigated. When suction pump stops, vacuum pressure remains inside the suction pump. Therefore, the effect of remaining vacuum pressure in the suction pump on fouling of membrane was investigated. The effect of EPS (Extra cellular Polymeric Substance) which is generated due to the long SRT and high concentration of MLSS and the dose of coagulant on the membrane were also investigated. The suitable oxic/anoxic time ratio for the best removal efficiency of organic matter and nitrogenous matter was 40 minutes (Oxic) : 20 minutes (Anoxic). At this time ratio, alum was dosed into the aeration tank. The result of dosing alum was that the concentration of alum solution might affect nitrification and denitrification. To remove 1 mg/L of phosphorus in MBR process, it needs 0.75 mg/L of alum solution.

PVA/Silica Hybrid Membrane Containing Sulfonic Acid Croup for Direct Methanol Fuel Cells Application (Sulfonic acid group을 갖는 PVA/Silica Hybrid막의 DMFC 응용)

  • Young Moo Lee;Dae Sik Kim;Kwang Ho Shin;Ho Bum Park;Ji Won Rhim
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.101-109
    • /
    • 2003
  • In the present study, crosslinked poly(vinyl alcohol) (PVA) membranes were prepared at various crosslinking agent content using sulfosuccinic acid (SSA) containing sulfonic acid group ($SO_3H)$. To reduce methanol permeability, silica was introduced to the membrane using sol-gel process. The hybrid membranes were studied in relation to proton conductivity and methanol permeability. It was found that both these properties were very dependent on the effect of SSA content as a crosslinking agent and as a donor of hydrophilic $SO_3H)$ group. The proton conductivities of these PVA/SSA/Silica membranes are in the range from $10^{-3}\;to\;10^{-2}$S/cm and the methanol permeabilities are in the range from $10^{-8}\;to\;10^{-7}\;cm^2/sec$.

상전이법에 의한 Polyetherimide 기체분리막 제조에서의 첨가제 효과에 관한 연구

  • 정용재;최성부;윤현희;김병식
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.94-95
    • /
    • 1997
  • 1. 서론 : Polyetherimide를 이용하여 기체분리용 고분자막을 제조하여 막 구조에 대한 첨가제 효과를 규명하고자 하였다. 막 제조는 상전환법에 기초한 습식방사법을 이용하여 Polyetherimide막을 제조하였다. 상전환법에 의한 막의 제조에 있어 막의 구조 및 투과성능은 사용되는 고분자용액의 농도 및 solvent의 종류 그리고 nonsolvent와 고분자 용액에 사용되는 첨가제와 밀접한 관계를 가지고 있다.

  • PDF

An Experimental Study on Sound Insulation Characteristic of Building Components (Steel Panel for Wall) (건축용벽판(철강제)의 차음특성에 관한 실험적 연구)

  • 김선우;송민정;유창남;이태강
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.13-17
    • /
    • 1995
  • 본 연구는 국내에서 생산되는 조립식 벽체 중 건축용벽판(철강제)의 재료구성, 부재간의 접합방식, 두께에 따른 투과손실의 특성을 실험실 실험을 통하여 비교, 분석함으로서, 건축용 벽판(철강제)의 차음성능개선을 위한 기초자료로 제시하고, KS F 4724로 규정된 차음기준에 대한 개선의 필요성을 언급하고자 한다.

  • PDF