• Title/Summary/Keyword: 투과깊이

Search Result 161, Processing Time 0.023 seconds

THE COMPARISON OF POLYMERIZATION OF COMPOSITE RESIN INFLUENCED BY CURING DEPTH AND SHADE (광중합 복합레진의 색상과 깊이에 따른 중합도의 비교)

  • Choi, Kung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.280-289
    • /
    • 2004
  • Adequate polymerization is a crucial factor in obtaining optimal physical properties and clinical performance of resin composite restorative materials. The purpose of this study was to determine the effectiveness of shade and depth on dental composite resin polymerized with plasma arc curing unit employing FTIR and microhardness. From this experiment, the following results were obtained : 1. The light transmission and microhardness by mode 6 in plasma arc curing were similar to by 20 secs in halogen light curing. 2. The experimental groups of A1, A2, A3, A3.5 were not signifcant difference to light transmission and microhardness on surface and 2mm depth, but were significant difference on 3mm and 4mm depth. Especially light transmission and microhardness were small in darker shade and deeper thickness. 3. Compared with depth cure, uncured monomer amount increased at more than 2mm depth. 4. The light transmission by FTIR and polymerization by microhardness were significant corelation.

  • PDF

Application and Improvement of Surface Wave Transmission Technique for Measuring the Crack Depth in Reinforced Concrete Members (철근 콘크리트 부재의 균열 깊이 측정을 위한 표면파 투과기법의 적용 및 개선)

  • Min, Ji-Young;Kim, Jae-Hong;Kwak, Hyo-Gyoung;Yun, Chung-Bang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.164-176
    • /
    • 2008
  • In order to assess the existing infrastructures, it is required to measure the crack depth of concrete members. This paper considers the surface wave transmission technique to measure the crack depth. In special, we demonstrate the effect of reinforced bar on surface wave propagation and conclude that the surface wave transmission technique has only the minor error by the reinforced bar. In addition, we propose and validate the optimal window size for eliminating various reflection waves from the boundary of members.

Simulation of Manipulating Various Pulsed Laser Operations Through Tuning the Modulation Depth of a Saturable Absorber (포화 흡수체의 투과변조깊이 조절을 통한 다양한 펄스상태 조작 방법에 관한 전산 모사)

  • Gene, Jinhwa;Yeom, Dong-Il;Kim, Byoung Yoon
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.351-355
    • /
    • 2017
  • In this paper, we conduct a simulation of manipulating various pulsed laser operations through tuning the modulation depth of the saturable absorber in a laser cavity. The research, showing that various pulsed operations could be manipulated from Q-switching through Q-switched mode locking to mode locking by tuning the modulation depth of the saturable absorber in a cavity, has been studied by experimental means. We conduct a simulation with the Haus master equation to verify that these experimental results are consistent with expectations from theory. The time dependence of the gain was considered to express Q-switching fluctuation through applying a rate equation with the Haus master equation. Laser operation was manipulated from mode locking through Q-switched mode locking to Q-switching as modulation depth was increased, and this result agreed well with the theoretical expectation.

Effect of scratches on optical connector interface surface on the insertion loss (광 커넥터 접합면의 스크래치가 삽입손실에 미치는 영향)

  • 윤영민;윤정현;김부균;신영곤;송국현
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.287-292
    • /
    • 2004
  • This paper presents the effect of scratches on an optical connector interface surface on the insertion loss of optical connectors. We propose a model for calculating the insertion loss of optical connectors. The model is expressed in terms of geometrical parameters of scratches assuming that the transmission coefficient of a light wave on the scratch surfaces is linearly varied as a function of scratch depth. Geometrical parameters of scratches such as location, width, and depth of scratches are measured using 3D optical interferometry surface profiler. We obtain the equation of the transmission coefficient in terms of scratch depth comparing the experimental insertion loss data to the insertion loss data using the model presented in this paper. Using the model and the equation of the transmission coefficient presented in this paper, we present the results of the insertion loss of optical connectors for various geometrical parameters of scratches. Scratches which are located at longer than two times the core radius from the center of the core show negligible effect on the insertion loss of optical connectors.

금속쐐기와 가상쐐기의 출력비교

  • 강위생
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.42-42
    • /
    • 2003
  • 목적 : 조사면 크기에 따른 금속쐐기와 가상쐐기에 의한 6 MV 와 15 MV 엑스선의 출력 및 상부와 하부 에 설치하는 금속쐐기의 출력을 비교하고자 한다. 대상 및 방법 : Varian Clinac21EX(미국)는 두부의 상부와 하부에 설치하는 각각의 금속쐐기와 제한기에 의한 가상쐐기 기능을 가지고 있다. 금속쐐기의 쐐기각은 네 가지 (15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$)이며 투과력에 무관하게 한 쐐기각에 대한 쐐기는 사하부는 각 1 개이고, 가상쐐기는 일곱 가지 ($10^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$) 이다. 각 쐐기에 대하여 3$\times$3~20$\times$20 $\textrm{cm}^2$ 의 조사면 크기에서 6 및 15 MV 엑스선의 쐐기출력인수 (wedge field output factor)를 $d_{max}$와 10 $\textrm{cm}^2$ 깊이에서 측정하였다. 조사면크기와 측정깊이에 따른 쐐기출력인수의 변화추이를 관찰하였다. 쐐기출력인수 O $F_{Wdg}$는 다음과 같다. O $F_{Wdg}$(r)= $D_{Wdg}$(r)/ $D_{op}$ ( $r_{0}$) 여기서 $r_{0}$와 r은 각각 민조사면의 기준조사면크기, 쐐기조사면크기이다. 하부쐐기에 대한 상부쐐기의 출력인수의 상대적인 백분율 차이, %ROD=l00$\times$(O $F_{upWdg}$/O $F_{lowWdg}$ lowWdg/ - 1)를 구하였다. 조사면크기와 깊이에 따른 %ROD의 변화추이를 평가하였으며 쐐기 각각에 대하여 출력인수를 측정해야하는지 평가하였다. 결과 : 금속쐐기에 대한 쐐기출력인수는 방사선의 투과력과 깊이에 관계없이 조사면 크기가 커짐에 따라 증가하였으나 가상쐐기의 쐐기출력인수는 쐐기각이 작은 경우에는 조사면크기가 커짐에 따라 증가하다가 감소하였으며 최대값을 보이는 조사면크기는 쐐기각이 커짐에 반하여 감소하였으며 투과력에 관계없이 60。 쐐기에 대해서는 조사면 크기가 4 cm(A/P=1) 이상에서 조사면크기가 커짐에 따라 감소하였다. 6 MV 엑스선 에 대한 10 cm 깊이에서 15。 쐐기와 15 MV 엑스선에 대한 10 cm 깊이에서 45。 쐐기의 A/P 가 1.5보다 작은 조사면을 제외하고는 조사면의 크기가 커짐에 따라 %ROD는 감소하였다. $d_{max}$에서는 15。 쐐기와 30。 쐐기에 대해서는 %ROD가 음수였으며 절대값이 증가하였다. 이는 곧 조사면의 크기가 커짐에 따라 상부쐐기의 쐐기출력계수가 하부쐐기와 접근하고 드디어는 상부쐐기의 출력인수가 하부쐐기의 출력인수보다 작아질 수도 있다는 것을 의미하고 있다. 또한 %ROD 는 쐐기각이 클수록 변화가 컸으며, 조사면 크기가 커짐에 따라 10 cm 깊이에서보다 $d_{max}$에서 더 급하게 감소하였다. %ROD 는 6 MV 엑스선에 대해서는 -0.52~4.18 % 였고, 15 MV 엑스선에 대해서는 -0.44-4.18 % 였다. 결론 : 두 가지 투과력의 엑스선이 방출되는 선형가속기의 상하부 쐐기와 가상쐐기의 출력인수를 측정하여 비교하였다. 결과에서 얻어진 결론은 아래와 같다. 1. 조사면의 크기가 커짐에 따라 금속쐐기의 출력계수 는 증가하였으나 가상쐐기의 경우는 증가하다가 감소하거나 큰 쐐기각에 대해서는 감소만 하였다. 2. 상부쐐 기와 하부쐐기는 쐐기출력인수가 4% 이상 차이가 날 수 있으므로 독립적으로 측정하여 이용하여야 할 것이다.것이다.다.

  • PDF

Evaluation of Crack-Repairing Performance in Concrete Using Surface Waves (표면탄성파를 활용한 콘크리트 균열 보수 성능 평가 기법)

  • Ahn, Eunjong;Kim, Hyunjun;Gwon, Seongwoo;Sim, Sung-Han;Lee, Kwang Myong;Shin, Myoungsu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.496-502
    • /
    • 2017
  • The purpose of this study is to investigate the applicability of surface-wave techniques for the evaluation of the crack-repairing performance of an epoxy injection method in concrete. In this study, box-shaped concrete specimens with four different crack depths were made with identical mix proportions. The specimens with different crack depths were completely repaired using the same epoxy injection method. The spectral energy transmission ratio of surface waves is used as an index to differentiate the effects of crack depth and crack-repairing performance. The decrease of spectral energy transmission ratio in accordance with the increase of crack depth was identified before repairing. Furthermore, the spectral energy transmission ratio increased after the crack-repairing process in all specimens. The spectral energy transmission ratio is considered as a great indicator for estimating the crack-repairing performance of the epoxy injection method; the ratio was recovered up to almost 95% of the uncracked condition.

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

A Study for Depth/color Dual Structure of Digitalized Image Signal - Experimental Approach (디지털 영상 신호 속에 내재된 깊이와 색상 정보의 이중적 구조에 대한 실험적 고찰)

  • Hwang, Jae-Ho;Jo, Jong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.747-749
    • /
    • 2003
  • 인간은 시각기관을 통해 영상을 읽어 들이고, 그 데이터로부터 대상 물체의 여러 정보를 취득한다. 물체가 놓여져 있는 빛 환경 하에서 반사, 굴절, 흡수, 투과 및 간섭 등과 같은 매우 복잡한 빛 작용의 결과인 영상이 눈에 입력된다. 이 여러 정보 가운데 깊이와 색상 정보는 매우 중요한 인간의 시각 식별 인지 능력이다. 이 논문은 깊이와 색상의 상관관계를 실험을 통해 규명하고자 하였다. 색상 변화는 grey tone으로 한정하였다. 깊이와 색상을 각각 독립변수로 설정한 실험 조건 하에서 디지털 영상신호 데이터를 취득, 분석하였다. 색상을 상수로 처리한 다음, 깊이를 변수로 등간격으로 변화시켜 실험한 후, 변수를 바꾸어 깊이를 상수로 놓고 색상을 다단계로 변화시켜 영상 데이터를 취득하였다. 빛의 조사(照射) 작도는 90도로 일정하게 두어 그림자 효과를 배제하였다. 디지털 영상 입력 과정에서 포함되기 쉬운 노이즈와 떨림, 초점 흐림 등을 전처리로 처리한 후 색도 변화를 분석하였다. 분석 결과, 이미지 속에 내재된 깊이와 색상 정보의 상호 이중적 구조 형태로의 존재를 규명하였다.

  • PDF

Measuring the Light Dosimetry Within Biological Tissue Using Monte Carlo Simulation (Monte Csrlo 시뮬레이션을 이용한 생체조직내의 광선량 측정)

  • 임현수;구철희
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 1999
  • As the correct measuring of the light dosimetry in biological tissues give the important affection to the effect of PDT treatment we used Monte Carlo simulation to measure the light dosimetry on this study. The parameters using in experiments are the optical properties of the real biological tissue, and we used Henyey-Greenstein phase function among the phase functions. As we results, we displayed the result the change of Fluence rate and the difference against the previous theory was at least 0.35%. Biological tissues using in experiment were Human tissue, pig tissue, rat liver tissue and rabbit muscle tissue. The most of biological tissue have big scattering coefficient in visible wavelength which influences penetration depth. The penetration depth of human tissue in visible region is 1.5~2cm. We showed that it is possible to measure fluence rate and penetration depth within the biological tissues by Monte Carlo simulation very well.

  • PDF

Analysis of Penetration Phenomenon of High Altitude Electromagnetic Pulse into Buried Facilities with Various Moisture Content and Depth (수분 함유량 및 지하 구조물 깊이에 따른 고고도 전자기파(HEMP) 투과 현상 분석)

  • Kang, Hee-Do;Oh, Il-Young;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.644-653
    • /
    • 2013
  • In this paper, a formulation for obliquely incident electromagnetic wave has been presented for an analysis of highpower electromagnetic pulse penetration into multilayered dispersive media. Based on generalized models of measured dielectric constants and propagation channels reflecting the Earth's general features, the propagation phenomenon of the obliquely incident early-time(E1) high altitude electromagnetic pulse(HEMP) is analyzed. In addition, the polarization and critical angle are also considered. It is found that the total reflection occurs at an incident angle of about 38 degrees at the soil-rock interface, and that the parallel-polarized E1 HEMP penetrates better than the perpendicular-polarized one. The peak level of the penetrating electric field is found to be 5.6 kV/m at normal incidence, regardless of the type of polarization, and E1 HEMP is greatly reduced near the critical angle. Moreover, the penetrating E1 HEMP is analyzed as a variation of moisture content and depth of materials, resulting E1 HEMP could be useful in determining the levels of shielding required for buried facilities.