• Title/Summary/Keyword: 통풍효과

Search Result 76, Processing Time 0.02 seconds

Cultural and chemical approaches for controlling postharvest diseases of garlics (마늘 저장병 방제를 위한 경종적, 화학적 접근)

  • Kim, Yong-Ki;Lee, Sang-Bum;Lee, Sang-Seob;Shim, Hong-Sik;Choi, Inn-Hoo
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.2
    • /
    • pp.139-148
    • /
    • 2003
  • The purpose of this study was to investigate damages of garlics occurred under cold storage and farmhouse storage condition, influence of cultural and environmental factors on storage spoilage of garlics, and to establish control strategies to reduce damages occurred under storage of garlics. Decays of garlics were highly related with cultural condition (paddy field or upland soil), ventilation, storage temperature and relative humidity, continuous cropping years, and harvesting stage. Early-harvested garlics were more decayed than late-harvested garlics. Garlics cultivated on paddy field were less decayed than ones cultivated on upland soil under farmhouse storage condition. The densities of Penicillium spp. and Fusarium spp. were higher on plot with long term continuous cropping cultivation history than on plot with short term continuous cropping cultivation history. However there is no relation between continuous cropping years and percent of decay of garlics. As a result of investigating influence of environmental factors on decay of garlics, P. hirsutum caused severe spoilage under high relative humidity condition, while F. oxysporum and Stemphyllium botryosum were not related with relative humidity. The three postharvest pathogens grew well above woe. In addition when P. hirsutum and S. botryosum were cultured for two months, they grew even at $-1^{\circ}C$. Except for environmental factors, wounds occurred through farming works. had an effect on storage spoilage of garlics. Garlics only hurt with a toothpick without inoculation of pathogens were decayed more severe than those inoculated with pathogens without wounds. Seven agro-chemicals showed highly suppressive effect were selected by measuring mycelial growth of three major pathogens of garlics on potato dextrose agar amended with 0.1% (v/v) of each fungicide. When they were foliar-sprayed on garlics 30 days before harvesting, it was confirmed that they suppressed storage spoilage of garlics. Also when garlics were sprayed with and drenched into the suspension of Benoram WP very after harvesting garlics, garlic damages by postharvest pathogens were reduced remarkably.

Optimized Controlled Atmosphere Regimen for Storage of Fresh Fischer's Ligularia (Ligularia fischeri Turcz.) Leaves (신선 곰취(Ligularia fischeri Turcz.) 잎 저장을 위한 CA 조성 최적화)

  • Park, Yoon-Moon;Kim, Taewan;Kim, Hyun-Seok;Kim, Tae Hoon;Park, Yoo Jin
    • Horticultural Science & Technology
    • /
    • v.33 no.3
    • /
    • pp.375-382
    • /
    • 2015
  • A controlled atmosphere (CA) regimen was optimized during 3 consecutive harvest seasons as the basis of practical modified atmosphere packaging (MAP) storage for quality maintenance and extension of storage potential of fresh Ligularia fischeri leaves. Leaves were harvested in April or May and forced-air cooled to $4^{\circ}C$ before punch-hole MAP (control, where gas concentrations were same as air) and CA treatments. CA regimens adjusted stepwise during 3 experimental years were: 1 and 3% $O_2$, respectively combined with 5 and 10% $CO_2$ in the first year, 3% $O_2$ fixed in combination with 0, 2.5, and 5% $CO_2$ in the second year, and 3% $O_2$ fixed in combination with 2.5 and 5% $CO_2$ in the third year. In the first year, higher incidence of black discoloration was observed with the reduction of respiration under 10% $CO_2$ CA conditions regardless of $O_2$ levels at 1 or 3%. In the second and third year, the incidence of the disorder seemed not to be clearly relevant to CA conditions showing slightly higher incidence only after 4- or 5-week storage + 5-day shelf life. Although texture and appearance quality were maintained better under the 3% $O_2$ + 2.5% $CO_2$condition after 4-week storage + 5-day shelf life, effects of CA on the extension of storage period was slight. Overall results indicated that Ligularia fischeri leaves are very susceptible to $CO_2$ injury. $CO_2$ concentration should be adjusted below 2.5% for safe and effective CA or MAP storage to maintain quality even during short-term storage.

A Study on the Eco-friendly Housing in the Near future based on the Ecological Design (생태학적 디자인을 기반으로 한 근 미래형 친환경주택연구)

  • Choo, Jin;Yoo, Bo-Hyeon
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.105-118
    • /
    • 2005
  • Housing environment for human beings has been diversified and more convenient due to the development of high technology and civilization brought by industrialization in the 20th century. In the 21st century, how to overcome the ecological limit of biased development-centered advancement, that is, how to preserve and hand over a clean and healthy 'sustainable environment' to our next generations has been one of the most-talked about issues. Environmental symbiosis means a wider range of environmental harmony from micro-dimensional perspective to macro one. The three goals of a environmentally friendly house are to preserve global environment, to harmonize with the environment around, and to offer a healthy and comfortable living environment. From the point of view of environmental symbiosis, houses should be designed to save energy and natural resources for preservation of global environment, to collect such natural energy resources as solar heat and wind force, to recycle waste water, and recycle and reduce the amount of the waste matter. Now, the environmentally-friendly house became a new social mission that is difficult to not only challenge but also realize without conversion to a new paradigm, ecologism.

  • PDF

Antioxidative Activities and Tyrosinase Inhibition Ability in Various Extracts of the Vitex rotundifolia Seeds (만형자(Vitex rotundifolia) 추출물의 항산화 활성과 Tyrosinase 저해 활성)

  • Lee, Yang-Suk;Choi, Bok-Dong;Joo, Eun-Young;Shin, Seung-Ryeul;Kim, Nam-Woo
    • Food Science and Preservation
    • /
    • v.16 no.1
    • /
    • pp.101-108
    • /
    • 2009
  • The purpose of this study was to measure flavonoid and polyphenol contents, and physiological activities of various extracts from Vitex rotundifolia seeds (known as Man Hyung Ja). We obtained three extracts using water (WE), ethanol (EE) and hot water (HWE). The EE sample had the highest flavonoid content of 31.05 mg/g. Polyphenol contents of WE and HWE were 186.69 mg/g and 182.55 mg/g, respectively. HWE had the highest superoxide dismutase (SOD)-like activity, at 83.40%. The electron donating abilities (EDA) were $91.14{\sim}95.97%$ at the concentration of 1.0 mg/mL, and all of extracts showed more than 88% EDA even at a concentration of 0.1 mg/mL. The inhibitory rates of xanthine oxidase were $94.02{\sim}97.51%$ when 1.0 mg/mL extracts were used, and all extracts showed more than 90% inhibition at 0.5 mg/mL. The nitrite scavenging abilities were $59.27{\sim}86.61%$ at pH 1.2 and 1.0 mg/mL extract concentration; these abilities decreased as pH increased. Tyrosinase inhibition activities of HWE and WE were 48.58% and 46.67%, respectively. These results indicate that Vitex rotundifolia seeds extract might be an effective antioxidative activity.

Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant (하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.18-35
    • /
    • 2019
  • The Korea District Heating Corporation operates a gas engine generator with a capacity of $4500m^3 /day$ of biogas generated from the sewage treatment plant of the Nanji Water Recycling Center and 1,500 kW. However, the actual operation experience of the biogas power plant is insufficient, and due to lack of accumulated technology and know-how, frequent breakdown and stoppage of the gas engine causes a lot of economic loss. Therefore, it is necessary to prepare technical fundamental measures for stable operation of the power plant In this study, a series of process problems of the gas engine plant using the biogas generated in the sewage treatment plant of the Nanji Water Recovery Center were identified and the optimization of the actual operation was made by minimizing the problems in each step. In order to purify the gas, which is the main cause of the failure stop, the conditions for establishing the quality standard of the adsorption capacity of the activated carbon were established through the analysis of the components and the adsorption test for the active carbon being used at present. In addition, the system was applied to actual operation by applying standards for replacement cycle of activated carbon to minimize impurities, strengthening measurement period of hydrogen sulfide, localization of activated carbon, and strengthening and improving the operation standards of the plant. As a result, the operating performance of gas engine # 1 was increased by 530% and the operation of the second engine was increased by 250%. In addition, improvement of vent line equipment has reduced work process and increased normal operation time and operation rate. In terms of economic efficiency, it also showed a sales increase of KRW 77,000 / year. By applying the strengthening and improvement measures of operating standards, it is possible to reduce the stoppage of the biogas plant, increase the utilization rate, It is judged to be an operational plan.

Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays (여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.52-61
    • /
    • 2013
  • This study was conducted to investigate the effects of pergola's shading on the thermal comfort index in the summer. The 3 type of pergolas($4m{\times}4m{\times}h2.7m$) which were screened overhead(I)/overhead west(II)/overhead west north(III) plane with reed blind for summer shading and winter wind break, were constructed on the 4th floor rooftop. Thereafter the meteorological variables(air temperature, humidity, radiation, and wind speed) of pergola I, III and rooftop were measured from 14 to 16 August 2013(1st experiment), those of pergola I, II and rooftop were measured from 26 to 28 August 2013(2nd experiment). The effects of pergola's shading on the radiation environment and mean radiant temperature($T_{mrt}$), standard effective temperature($SET^*$) were as follows. The maximum 1 h mean values of differences ${\Delta}$ of the sums of shortwave radiant flux densities absorbed by the human body (${\Delta}K_{abs,max}$) between pergola I, III and nearby sunny rooftop were $-119W/m^2$, $-158W/m^2$, those between pergola I, II and rooftop were $-145W/m^2$, $-159W/m^2$. The maximum 1 h mean values of differences ${\Delta}$ of the sums of long wave radiant flux densities absorbed by the human body (${\Delta}L_{abs,max}$) between pergola I, III and nearby sunny rooftop, were $-15W/m^2$, $-17W/m^2$, those between pergola I, II and nearby rooftop, were $-8W/m^2$, $-7W/m^2$. The response of the direction dependent long wave radiant flux densities $L_1$ on the pergola's shading turned out to be distinctly weaker as compared to shortwave radiant flux densities $K_1$. The pergola's shading leads to a lowering of $T_{mrt}$ and $SET^*$. The peak values of $T_{mrt}$ absorbed by the human body were decreased $16^{\circ}C$ and $21.4^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $18.8^{\circ}C$ and $20.8^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The peak values of $SET^*$ absorbed by the human body were decreased $2.9^{\circ}C$ and $2.6^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $3.5^{\circ}C$ and $2.6^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The relative $SET^*$ decrease in pergola II, III compared to nearby sunny rooftop $SET^*$ were lower than that in pergola I, revealing the influence of the wind speed. Therefore it is essential to design pergola to maximize wind speed and minimize solar radiation to achieve comfort in the hot summer. The $SET^*$ under pergola I, III were exceeded $28.7^{\circ}C$ and $30.4^{\circ}C$ which were the upper limit of thermal comfort and tolerable zone during all most daytimes in the 1st experiment(maximum air temperature $37.5^{\circ}C$). The $SET^*$ under pergola I was exceeded $28.7^{\circ}C$ which was the upper limit of thermal comfort zone at 13h, that under pergola II was exceeded $28.7^{\circ}C$ from 8h to 14h, meanwhile the $SET^*$ under pergola I, II were within thermal tolerable zone during most daytimes in the 2nd experiment(maximum air temperature $34.4^{\circ}C$). Therefore to ensure the thermal comfort of pergola for summer hottest days, pergola should be shaded with not only reed blind but also climbing and shade plants. $T_{mrt}$ and $SET^*$ were suitable index for the evaluation of pergola's shading effects and outdoors.