• Title/Summary/Keyword: 토출온도

Search Result 91, Processing Time 0.022 seconds

The Texturization Properties of Textured Extrudate made by a Mixture of Rice Flour and Isolated Soybean Protein (쌀과 분리대두단백 혼합에 따른 조직화 특성)

  • Han, Ouk;Park, Yong-Ho;Lee, Sang-Hyo;Lee, Hyun-Yu;Min, Byong-Lyoung
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.780-787
    • /
    • 1989
  • The texturization properties of extrudate from isolated soybean protein and rice flour by extrusion cooking were investigated. The addition of up to 30% rice flur to isolated soy proetin could give more tenderness to the texturized extrudate. As the rice flour content increased, die temperature, nitrogen solubility index, and integrity index were decreased slightly with lower chewiness and gumminess. The water content of final extrudate was increased as the addition of rice flour increased, while density was maintained without variation, and rehydration ratio was decreased. The distribution of pressure profile during extrusion were in the range of $15-100kg/cm^3$. As the addition of rice flour increased, scanning electron micrographs demonstrated the gelatinized surface structure of rice starch and the increased air cell size of the testurized extrudate.

  • PDF

Performance of HFC32/HFC125 Mixtures for Heat Pumps (HFC32/HFC125 혼합냉매의 히트펌프 성능 평가)

  • Kim, Wook-Jin;Kang, Dong-Gyu;Lee, Yo-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

An Experimental Study on the Concrete Pumping Technology of High Performance Concrete for the High-Rise Building Construction (초고층 구조물 시공을 위한 고성능 콘크리트의 펌프압송 기술에 관한 실험적 연구)

  • Kim, Gyu-Dong;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.375-381
    • /
    • 2015
  • In this study, high performance concrete of C60 and C80 were applied to a super tall building and those had satisfactory properties of fresh and hardened concrete to the requirements even changes according to time. Especially the evaluation and analysis of the relation of the rheological properties and puMPability of high performance concrete, C60-14 which was applied to the height of from 500m to 575m in the building, was carried out bymeasuring pumping pressure and pumping speed, testing concrete properties at before and after pumping. As results, themax. pumping pressure showed increase of 5% at every 25m higher pumping and the average pumping speed showed the above $25m^3$ per hour whichmeans proper productivity. Additionally it was verified that the loss of slump flow after pumping was increased according to plastic viscosity values and the increment of temperature through concrete pumping.

On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor (CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구)

  • Kim, Gyu Wan;Park, Jin Ouk;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.873-879
    • /
    • 2014
  • In the present study, water vapor is injected at various positions in a Clean Dry Air (CDA) system such as a system inlet duct, compressor inlet, and compressor outlet by humidified air turbines. The application of evaporative cooling reduces the compression work and enhances the Energy Consumption Index (ECI) per unit volume. The main purpose of this study is to investigate the compressor power performance with different inlet air temperatures and humidity conditions. It is found that the actual power consumption and discharge flow are significantly influenced by the inlet air temperature as well as relative humidity. The results obtained during this study are compared both numerically and experimentally and are found to be in very good agreement.

Shell and Tube Heat Exchanger Performance Estimation by Changing Shell-side Fluid Characteristics (쉘-튜브 열교환기에서의 쉘쪽 유체의 특성에 따른 열교환기 성능 변화 예측 사례)

  • Baek, Seungwhan;Jung, Youngsuk;Cho, Kiejoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.27-37
    • /
    • 2019
  • The shell and tube heat exchangers installed in the propulsion system test complex (PSTC) at the Naro Space Center heats cryogenic helium to 500 K with a heat transfer oil. As the experimental helium outlet temperature was lower than expected (less than 100 K), the boundary layer effect of the heat transfer oil is predicted to be the cause of the performance deterioration. A computational fluid dynamics (CFD) analysis was performed to verify where the boundary layer effect exists; however, the boundary layer effect has no significant impact on the performance of the heat exchanger. An alternative method to improve the performance of the heat exchanger by changing the heat transfer oil has been discussed in this paper. The low viscosity and high thermal conductivity at high temperature (~500 K) of heat transfer oil at the shell-side are required to improve the thermal performance of the heat exchanger. The experimental performance of the heat exchanger, used to exchange heat between the cryogenic helium and hot heat transfer oil at the PSTC are summarized in this paper.

Development of Artificial Intelligence Model for Outlet Temperature of Vaporizer (기화 설비의 토출 온도 예측을 위한 인공지능 모델 개발)

  • Lee, Sang-Hyun;Cho, Gi-Jung;Shin, Jong-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.85-92
    • /
    • 2021
  • Ambient Air Vaporizer (AAV) is an essential facility in the process of generating natural gas that uses air in the atmosphere as a medium for heat exchange to vaporize liquid natural gas into gas-state gas. AAV is more economical and eco-friendly in that it uses less energy compared to the previously used Submerged vaporizer (SMV) and Open-rack vaporizer (ORV). However, AAV is not often applied to actual processes because it is heavily affected by external environments such as atmospheric temperature and humidity. With insufficient operational experience and facility operations that rely on the intuition of the operator, the actual operation of AAV is very inefficient. To address these challenges, this paper proposes an artificial intelligence-based model that can intelligent AAV operations based on operational big data. The proposed artificial intelligence model is used deep neural networks, and the superiority of the artificial intelligence model is verified through multiple regression analysis and comparison. In this paper, the proposed model simulates based on data collected from real-world processes and compared to existing data, showing a 48.8% decrease in power usage compared to previous data. The techniques proposed in this paper can be used to improve the energy efficiency of the current natural gas generation process, and can be applied to other processes in the future.

Research of Dry Reduction Process of Waste Tin Oxide using Methane (메탄가스를 이용한 폐주석산화물의 건식환원시스템)

  • Hyun-Chul Jung;Se-Kwon Kim;Sang-Yeol Kim
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.18-24
    • /
    • 2022
  • Dry reduction using natural gas was proposed to recover tin from waste tin oxide generated in a tin bath that was used for controlling the smoothness of architectural glass during production, and the reduction behavior was investigated. The utilized vertical natural gas dry reduction system is capable to process 4 L or 20 kg depending on input raw materials. The system was established by applying the upper intake and lower discharge method. The recovery rate was 97.2% at 800 ℃ and 4 sccm flow rate and increased with the amount of input gas. Hydrogen accounted for 23% of the discharge gas, showing a 16.6% hydrogen conversion rate. The reaction behavior of tin recovered via natural gas reduction provides basic data on the new waste resource reduction/recovery technology.

Characteristics of the Dependent Variable due to Changes in the Conditions of the Independent Variable During the Producing of Collets Added with Rice and Dried Shrimp by Single Extruder (Single Extruder를 이용한 마른새우첨가 쌀 Collets 제조 시 독립변수의 조건변화에 따른 종속변수의 특성)

  • JE, Hae-Soo;YOON, Moon-Joo;LEE, Jae-Dong;KANG, Kyung-Hun;PARK, Si-Young;PARK, Jin-Hyo;KIM, Jeong-Gyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1352-1363
    • /
    • 2015
  • This study was carried out to investigate the characteristics of the dependent variables depending on the condition changes of independent variable of the operation and the material during the production of collets added with rice and dried shrimp by using single extruder to utilize as basic data for the manufacture of extrusion collets. A total of 7 independent variables were set up as a raw, 20, 40 and 60 mesh for the powder particle size of rice; 12, 14, 16 and 18% for the moisture content of rice; 2, 4, 6 and 8% for the addition amount of dried shrimp; 90, 95, 100 and $110^{\circ}C$ for the barrel temperature; 210, 280 and 340 rpm for the screw speed; 4, 6, 8 and 10 mm for the discharge port diameter; 30, 40, 50 and 60 kg/h for the input amount of the mixed material. The characteristics of the dependent variables including puffing ratio, moisture content, lightness, uniformity, productivity of collets was to be studied by changing the conditions of the independent variables. As a results of this study, 20 mesh of powder particle size of rice, 14% of moisture content of rice, 4% of addition amount of dried shrimp, $100^{\circ}C$ of barrel temperature, 280 rpm of screw speed, 6 mm of discharge port diameter and 50 kg/h of input amount of mixed material were found to be the most preferable over other independent variables for the production of extrusion collets. In conclusion, it is necessary to set the independent variable in order to produce the high quality collets added with the rice as the main raw material and dried shrimp as the sub-materials.

A Study on the Physicochemical Properties of Extrudate Containing Sea Mustard by Single Extruder (미역을 함유한 압출성형물의 이화학적 특성에 관한 연구)

  • DO Jeong-Ryong;OH Sang-Lyong;KIM Young-Myoung;KIM Dong-Soo;JO Jin-Ho;MOON Kwang-Duk;JO Kil-Suk;KOO Jae-Guen
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.1
    • /
    • pp.13-26
    • /
    • 1994
  • The present study was focused on investigation of proper processing conditions to develop physicochemical properties of extrudates using sea mustard and corn by single extruder. Response surface analysis was used to evaluate effects of extrusion variables on the quality of the extrudates. Physicochemical dependence variables of sea mustard extrudates with corn grits show a significance correlation of within $5\%$. Among the various dependence variables, the expansion ratio showed a high correlation with bulk density, break strength, water solubility index and yellowness. Bulk density correlated closely with water solubility index; break strength with water absorption index and lightness, and water absorption index with lightness. Water solubility index and lightness showed a significance correlation with yellowness of within $0.5\%$. Three dimensional graphic analysis on response surface regression was conducted with each of the dependent variables which revealed statistically significant relationship to independent variables: $15{\sim}21\%$ moisture content, $10{\sim}30\%$ sea mustard content and $95{\sim}115^{\circ}C$ die temperature. Expansion ratio decreased with increasing moisture and sea mustard content. It showed the highest value at $18\%$ moisture content, $10\%$ sea mustard content and $95^{\circ}C$ die temperature. and the lowest value was at $21\%$ moisture content, $30\%$ sea mustard content and $105^{\circ}C$ die temperature. Bulk density was highest at $21\%$ moisture content, $30\%$ sea mustard content and $105^{\circ}C$ die temperature. On the other hand, it was lowest at $18\%$ moisture content, $10\%$ sea mustard content and $95^{\circ}C$ die temperature. Break strength was highest at $18\%$ moisture content, $10\%$ sea mustard content and $115^{\circ}C$ die temperature, but lowest at $21\%$ moisture content, $30\%$ sea mustard content and $105^{\circ}C$ die temperature. Water solubility index increased in the range of $43.9{\sim}54.8\%$ as the moisture content increased.

  • PDF

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.