• Title/Summary/Keyword: 토양증기추출

Search Result 36, Processing Time 0.03 seconds

토양증기추출공정 중 오염물의 거동평가기법에 관한 연구

  • 조현정;권태순;양중석;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.354-355
    • /
    • 2003
  • In this study, a risk-based cleanup approach using the leaching potential was suggested for the soil vapor extraction (SVE) process. A multi-component model was adopted with local equilibrium assumption (LEA), and Raoult's law was applied to estimate the leaching potential for BTEX. Finally, a risk analysis was conducted based on the leaching pontential calculated. To complete the feasibility of this approach, more investigations and discussions will be required in future.

  • PDF

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

토양오염 유발시설의 오염현황 조사 및 오염토양 복원 방안 연구

  • 노성혁;백형환;신정남
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.344-347
    • /
    • 2003
  • 본 조사를 통해 토양오염유발시설 중 유류 유출사고가 잦은 주유소에서의 오염현황 조사방법과 오염토양에 대한 적정한 정화기법을 제시하고자 하였다. 오염현황 조사결과, 지층구조 는 전반적으로 Clay로 구성되어 있으나 오염토양 주변은 비교적 투수도와 통기성이 우수한 Silty Sand층을 나타내고 있었다. 본 주유소의 경우 주유기 주변(상층부)과 지하유류저장탱크 주변(수직분포)에 오염이 분포되어 있고, 오염원인은 주유기의 배관 파손 및 결함에 의해 발생한 것으로 예상된다. 본 조사지역에 대한 정화기법으로는 토양증기추출기술(SVE)과 불포화대를 생물학적으로 복원할 수 있는 바이오벤팅기술을 결합시킨 Bioslurping이 효과적일 것으로 평가된다. 또한 Bioslurry injection treatment를 병행하여 효과적으로 고농도의 오염토양을 처리하는 것이 바람직할 것으로 판단된다.

  • PDF

Analysis of Soil Vacuum Extraction using Analytical Solution of Groundwater Flow (지하수 흐름의 해석해를 이용한 토양진공추출 해석)

  • Kim, Min-Hwan;Lee, Hak;Han, Dong-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.139-145
    • /
    • 2009
  • An analytical solution of groundwater flow is applied to design soil vacuum extraction for removing volatile organic compounds from the unsaturation zone. The governing equation of gas or vapor flow in porous media is nonlinear in that gas density depends on gas pressure. A linear equation suggested by researcher is similar to that of groundwater flow. The pressure drawdowns of confined and leaky aqufiers are calculated using Massmann's field data, and the pressure drawdowns are compared. A solution of Theis equation calculated by Massmann is modified using GASSOLVE9 program in this paper. The pressure drawdown using Hantush's analytical solution for leaky aquifer also compared to that of Massmann. Hantush's analytical solution gives good approximations to pressure drawdown.

Remediation of Contaminated Railroad Soils using by Hybrid Pilot System (Hybrid Pilot System을 이용한 철도 오염토양 복원)

  • 박덕신
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.3
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, we tested hybrid pilot system combined with soil vapor extraction and bioventing methods on the contaminated railroad soil. So, we found out the remediability and operating conditions. Air permeability(k) and gas phase(O$_2$/CO$_2$/VOCs) level trend are very important to determine the remediation rate of the contaminated sites. Throughout hybrid pilot test on different conditions, the range of air permeability(k) was 1985∼1194 darcy. The tests results in hybrid system was appropriate on this test sites, and the suitable injection air flow rate was 3.5㎥/hr. So, we suggested a basic data for the remediation and management of contaminated railroad soil.

  • PDF

The In-Situ Ozone Oxidative Remediation Potential of Diesel Fuel-contaminated Soil (디젤오염토양에 대한 지중 오존산화처리 적용 가능성)

  • 유도윤;신응배;배우근
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.3-15
    • /
    • 1999
  • This paper includes the basic experimental results performed for developing an innovative and technologically feasible process wherein gaseous ozone, a powerful oxidant. is injected directly into vadose zone by which in-situ chemical degradation of semi- or, non-volatile petroleum product such as diesel fuel is derived. As ozone gas injected continuously(50mL/min, 119.0$\pm$6.1mg/L) into soil packed columns artificially contaminated with diesel fuel(initial concentration 1,485mg-DRO/kg/soil), the removal rates at the inlet and outlet point of 14hrs-operated column are 87.9% and 100.0%, respectively. On the other hand, soil vapor extraction system showed less than 30% of removal rates of residual diesel both at the inlet and outlet samples under the same experimental conditions which confirms the limited treatability of SVE in diesel contaminated soil.

  • PDF

Hot Air Injection/Extraction Method for the Removal of Semi-Volatile Organic Contaminants from Soils (토양내 저휘발성 유류오염물 제거를 위한 고온공기 주입/추출기술 연구)

  • Gu Chung-Wan;Ko Seok-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.6-12
    • /
    • 2005
  • Contamination of soils and groundwater by leakage of petroleum compounds from underground storage tanks (USTs) has become great environmental issues. Conventional methods such as soil vapor extraction (SVE) used for the remediation of unsaturated soils contaminated with volatile organic compounds might not be applied for the removal of semi-volatile organic compounds such as diesel fuels and PCBs, which have low volatility and high hydrophobicity. The objective of this study is to develop a hot air injection method to remove semi-volatile compounds. Additionally, operation parameters such as temperature, air flow rate, and water content are evaluated. Experimental results show that diesel ranged organics (DROs) are removed in the order of volatility of organic compounds. As expected, removal efficiency of organics is highly dependent on the temperature. It is considered that more than $90\%$ of organic contaminants whose carbon numbers range between 17 and 22 can be removed efficiently by the hot air injection-extraction method (modified SVE) over the $100^{\circ}C$. It is also found that increased air flow rate resulted in high removal rate of contaminants. However, air flow rate over 40 cc/min is not effective for the operation aspects, due to mass transfer limitation on the volatilization rate of the contaminants. The effect of the water content on the decane removal is minimal, but some components show large dependence on the removal efficiency with increasing water content.

Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation (오염토양 복원을 위한 연직배수시스템의 지반공학적 특성)

  • Shin, Eunchul;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.5-14
    • /
    • 2007
  • The quantity of noxious wastes generated by the growth in industrialization and population in all over the world and its potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. Incorporated technique with PVDs have been used for dewatering from fine-grained soils for the purpose of ground improvement by means of soil flushing and soil vapor extraction systems. This paper is to evaluate several key parameters that affected to the performance of the PVDs specifically with regard to: well resistance of PVD, zone of influence, and smear effects. In the feasibility of contaminant remediation was evaluated in pilot-scale laboratory experiments. Well resistance is affected on the vertical discharge capacity of the PVDs under the various vacuum pressures. The discharge capacity increases consistently in areal extents with higher applied vacuum up to a limiting vacuum pressure. The head values for each piezometer at different vacuum pressures show that the largest head loss occurs within 14 cm of the PVD. Air flow rates and head losses were measured for the PVD placed in the model test box and the gas permeability of the silty soils was calculated. Increasing the equivalent diameter results in a decrease in the calculated gas permeability. It is concluded that the gas permeability determined over the 1,500 to 2,000 $cm^3/s$ flow rates are the most accurate values which yields gas permeability of about 3.152 Darcy.

  • PDF

세라믹 가스센서를 이용한 토양증기추출공정의 배출가스 모니터링 기법 연구

  • 양지원;조현정;이재영;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.250-252
    • /
    • 2002
  • The goals of environmental monitoring are to locate and quantify the significant contamination, estimate the fate and transport, estimate the potential exposure and risks to humans and the environment, and track the performance of various remedial technologies. In this study, ceramic gas sensor system is proposed to enhance the effectiveness of soil vapor extraction (SVE) process by monitoring the effluent gas. SVE is a technique that is widely used to remediate unsaturated soils contaminated with volatile organic contaminants. The sensor response for benzene, toluene, and xylene, the representative effluent gas compositions of SVE process, was evaluated using the proposed sensor system. As a result, it was verified that the response of sensor was increased or decreased very sensitively according to the change of the effluent gas concentration. Besides, the sensor could detect the difference over a wide range of concentration and it was more sensitive in order of xylene, toluene, and benzene. It is expected that this VOC analysis method results in field monitoring costs saying and appropriate immediate action for process control. More detailed experiments are being conducted in our research group.

  • PDF

A Study on Remediation Methods of Contaminated Soils at Former Military Bases (군기지 오염토양의 정화 방법에 대한 연구)

  • Yang, Hyuksoo;Kim, Im Soon;Kang, Seon-Hong;Chang, Yoon Young;Park, Sehkyu;Ko, Jae Wook;Kim, Yunjung;Park, Chulhwan
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.647-651
    • /
    • 2014
  • Handling of the large quantity of oil, generation of heavy metals at the military blasting range and outworn facilities could cause the environmental accidents. Pollution levels of the former five U.S military bases located in Uijeongbu, Gyeonggi-do were measured. Soil contamination by TPH (Total Petroleum Hydrocarbons), BTEX (Benzene, Toluene, Ethylbenzene, Xylene), and heavy metals and groundwater contamination were detected. In order to purify contaminated soil, a variety of technologies including soil vapor extraction, slurping, landfarming and soil washing were applied. Contaminated soils of five target bases were purified and the results were suitable for the legal standards.