• Title/Summary/Keyword: 터빈효율

Search Result 463, Processing Time 0.021 seconds

Performance of Oscillating Water Column type Wave Energy Converter in Oblique Waves (사파중 진동수주형 파력발전장치의 성능평가)

  • Jin, Jiyuan;Hyun, Beom-Soo;Hong, Keyyong;Liu, Zhen
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2014
  • In an oscillating water column (OWC)-type wave energy conversion system, the performance of the OWC chamber depends on the chamber shape, as well as the incident wave direction and pressure drop produced by the turbine. Although the previous studies on OWC chambers have focused on wave absorbing performance in ideal operating conditions, incident waves do not always arrive normally to the OWC chamber in real sea conditions, especially in fixed devices. The present study deals with experiments and numerical calculations to investigate the effects of wave direction on the performance of the OWC chamber. The experiments were carried out in a three-dimensional wave basin for five different wave directions, including the effect of turbine using the corresponding orifice. The wave elevation inside the chamber was measured at the center point under various incident wave conditions. The numerical study was conducted by using a numerical wave tank-based volume-of-fluid model to compare the results with experimental data and to reveal the detailed flows around the chamber.

Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters (운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.580-585
    • /
    • 2012
  • In this paper, the cycle performance analysis for condensation and evaporation capacity, total work and efficiency of ocean thermal energy conversion power system using R744 ($CO_2$) is presented to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include superheating and subcooling degree, evaporation and condensation temperature, pump and turbine efficiency. The main results were summarized as follows : The evaporation capacity of R744 increases with superheating and subcooling degree, but decreases with the increasing condensation temperature. The total work increases with superheating and subcooling degree of R744, but decreases with the increasing evaporating temperature. And, the efficiency increases with subcooling and superheating degree, but decreases with the increasing condensation temperature. Therefore, superheating and subcooling degree, evaporation and condensation temperature and pump and turbine efficiency of R744 OTEC power system have an effect on the evaporation and condensation capacity, total work and efficiency of this system. With a thorough grasp of these effect, it is necessary to design the OTEC power cycle using R744.

Simulation Study on Liquid Air Energy Storage (LAES) System using Dual Refrigeration Cycles and Thermal Oil Circulation (냉매사이클과 열매체유 순환을 활용한 액화공기에너지저장 시스템 공정모사 연구)

  • Jang, Soonnam;Park, Jongpo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.63-73
    • /
    • 2018
  • Innovative technical process for Energy Storage System (ESS), Liquid Air Energy Storage system (LAES) is mature technologies based on the gas liquefaction process. In spite of many advantages such as high energy density, no geographical constraints, low investment costs and long useful life, the system has not yet widely commercialized due to low round trip efficiency. To improve RTE and acquire high yield of liquid air, various configurations of LAES process have been considered. In this research, dual refrigerants cycle (R-600a and methanol) for air liquefaction and thermal oil circulation for power generation via liquid air gasification have been applied to improve cycle performance significantly using Aspen HYSYS simulator.

Correlation of Reflection Coefficient and Extracted Efficiency of an Oscillating Water Column Device in Front of a Seawall (안벽 앞에 설치된 진동수주형 파력발전장치의 반사율과 추출효율과의 상관관계)

  • Cho, Il Hyoung;Kim, Jeongrok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.242-251
    • /
    • 2020
  • In this study, the extraction efficiency and reflection coefficient by a two-dimensional OWC (Oscillating Water Column) WEC (wave energy converter) installed in front of a seawall was investigated for regular/irregular waves. The matched eigenfunction expansion method (MEEM) based on the linear potential theory was applied as an analytical tool. The diffraction problem by the incident wave in the open-chamber and the radiation problem by the oscillating pressure in the closed-chamber were solved to obtain the volume fluxes at the internal free-surface. Applying the volume fluxes into the continuity equation for the airflow in a chamber, we got the oscillating air pressure. The maximum extracted power and corresponding reflection coefficient were determined at the optimal turbine coefficient that maximizes the extracted power. OWC device designed for a high extracted efficiency simultaneously contributes to reduce reflected waves.

Application of InVEST Offshore Wind Model for Evaluation of Offshore Wind Energy Resources in Jeju Island (제주도 해상풍력 에너지 자원평가를 위한 InVEST Offshore Wind 모형 적용)

  • KIM, Tae-Yun;JANG, Seon-Ju;KIM, Choong-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.47-59
    • /
    • 2017
  • This study aims to assess offshore wind energy resources around Jeju Island using the InVEST Offshore Wind model. First the wind power density around the coast of Jeju was calculated using reanalysis data from the Korean Local Analysis and Prediction System (KLAPS). Next, the net present value (NPV) for the 168MW offshore wind farm scenario was evaluated taking into consideration factors like costs (turbine development, submarine cable installation, maintenance), turbine operation efficiency, and a 20year operation period. It was determined that there are high wind resources along both the western and eastern coasts of Jeju Island, with high wind power densities of $400W/m^2$ calculated. To visually evaluate the NPV around Jeju Island, a classification of five grades was employed, and results showed that the western sea area has a high NPV, with wind power resources over $400W/m^2$. The InVEST Offshore Wind model can quickly provide optimal spatial information for various wind farm scenarios. The InVEST model can be used in combination with results of marine ecosystem service evaluation to design an efficient marine spatial plan around Jeju Island.

Energy Analysis of Constant-Pressure Compressed Air Energy Storage (CAES) Generation System (정압식 압축공기저장(CAES) 발전 시스템 에너지 분석)

  • Kim, Young-Min;Lee, Sun-Youp;Lee, Jang-Hee
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.178-184
    • /
    • 2011
  • Compressed Air Energy Storage (CAES) is a combination of energy storage and generation by storing compressed air using off-peak power for generation at times of peak demand. In general, both charging and discharging of high-pressure vessel are unsteady processes, where the pressure is varying. These varying conditions result in low efficiencies of compression and expansion. In this paper, a new constant-pressure CAES system to overcome the current problem is proposed. An energy analysis of the system based on the concept of exergy was performed to evaluate the energy density and efficiency of the system in comparison with the conventional CAES system. The new constant-pressure CAES system combined with pumped hydro storage requires the smaller cavern with only half of the storage volume for variable-pressure CAES and has a higher efficiency of system.

A Study of Vertical Axis Wind Turbine (수직축 풍력터빈에 관한 연구)

  • park, Jung-Cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.389-395
    • /
    • 2017
  • This paper showed the difference in the optimum conditions by using the ANSYS CFX simulation program with the changes of the main-blade angle and sub-blade angle. Main-blade Shape 4,which had angle $45^{\circ}$ while other Shapes with angle $0^{\circ}$, was increased to 157.2[%] to 263.2[%] in the power and was increased to 110[%] to 250[%] in the power coefficient. Moreover, when the Shape 5 Fin length of main-blade doubled, the power was 70.8[%] when compared with Shape 1 and 27.5[%] with shape 4.If the main-blade geometry equals shape 1 in the case structure, The power of Case1 was increased to 13.3[%] when compared with Case2. Also, the power coefficient was increased to 15.4[%]. When sub-blade angle was $45^{\circ}$, main-blade was better than the Fin type than the Bended type. The power of Case4 was increased to 47[%] when compared with Csae1 and increased to 13.6[%] with Case 3. Also, the power coefficient was 46.7[%] when compared with Case 1 and 15.8[%] with Case 3.

A Numerical Study on Tip Rake HAT Impeller Performance for Tidal Stream Power (조류발전용 팁 레이크 HAT 임펠러 성능 수치해석 연구)

  • Shin, Byung-Chul;Kim, Moon-Chan;Do, In-Rok;Rhee, Shin-Hyung;Hyun, Beom-Soo;Song, Mu-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.263-269
    • /
    • 2010
  • The present study deals with the investigation about the improvement of performance of tidal stream turbine blade (HAT) with tip rake. HAT impeller has sometimes experienced noise and vibration by Tip vortex which causes even erosion and severe efficiency loss to the blade, The newly proposed tip rake impeller can make the tip vortex week compared with a normal impeller by preventing the three dimensional effect at tip region. In order to find out the optimum rake impeller, three cases have been designed and the performance of the designed rake impellers has been validated by the commercial CFD code(Fluent). The efficiency of optimized rake impeller was up to 4.6% higher than the conventional impeller. The more parametric study for high efficiency and good cavitation performance is expected to be conducted in a near future.

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.

Simultaneous Treatment of Tar and Particles Using Oil Scrubber and Bag Filter in Biomass Gasification (오일 스크러버 및 집진장치를 통한 바이오매스 가스화 공정 발생 타르 및 입자 제거 연구)

  • Kim, Joon Yub;Jo, Young Min;Kim, Sang Bum
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.712-718
    • /
    • 2019
  • A combustible producer gas composed of H2, CO and CH4 could be obtained by the thermal-chemical conversion of biomass. However, a large amount of particulate matters including tar generated causes the mal-function of turbines and engines or the fouling of pipelines. In this study, a wet scrubber using the soybean oil and bag filter were installed, and the removal efficiency was investigated. Hydrate limestone and wood char base activated carbon were pre-coated on the filter medium to prevent clogging of open pores. The removal efficiencies by the bag filter were 86 and 80% for the hydrated limestone and activated carbon coating, respectively. Overall, the collection when using a series of oil scrubbers and bag filters were 88%, while 83% for the filter coating material.