• Title/Summary/Keyword: 터빈동

Search Result 122, Processing Time 0.029 seconds

A Case Study on Explosive Demolition of Turbine Building of Steel Frame Structure (터빈동 철골구조물 발파해체 시공사례)

  • Hoon, Park;Sung-Woo, Nam;You-Song, Noh;Chul-Gi, Suk
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.35-46
    • /
    • 2022
  • While the construction of dismantling the old industrial complex and restoring the dismantled industrial site to its original natural environment the is underway. In this paper, we introduce a case of dismantling a turbine building which one of the a large steel frame structures in an old industrial complex by applying the progressive collapse method among the blasting demolition methods. We used a charge container that generates a metal jet to cut dismantling the turbine building. The thickness of the steel structure was adjusted to 30 mm or less by applying gouging, which was a method of digging deep grooves by gas and oxygen flames or arc thermal, in the part where the cutting thickness was thick in the blasting section. The total amount of charge used for the blasting of turbine building was 175 kg, 165 electronic detonators and 124 charge containers. As a result of the blasting demolition, the turbine building was collapsed precisely according to the estimated direction. The blasting demolition was completed without causing any damage to the surrounding facilities.

발전 설비에서의 윤활 기술의 응용

  • 김호종
    • Journal of the KSME
    • /
    • v.32 no.11
    • /
    • pp.955-967
    • /
    • 1992
  • 발전 설비는 다양한 부품으로 구성되어 있으며, 많은 부분이 회전력에 의해 운전된다. 대표적인 터빈, 발전기, 펌프, 송풍기 등이 있다. 모든 회전체에는 그것을 지지하면서 마찰을 줄여 회전을 원할하게 하기 위하여 베어링을 사용한다. 베어링은 회전체의 마찰에 의한 동력 손실을 줄일 뿐 아니라 회전체의 동특성에도 영향을 준다. 또한 회전체 운전중 문제점의 원인 중 많은 경우가 베어링에 기인하므로 회전체 제작시 베어링이 적절히 선정되고 설계되어야 한다. 발전 설비에 설치되는 베어링 중 가장 큰 부분을 차지하는 것이 터빈-발전기용 베어링이다. 터빈-발전기용 베어링은 마찰에 의한 동력 손실이 발전소 용량의 약 0.5%를 차지하며, 터빈-발전기 축계의 동 특성을 고려한 설계에서 중요한 요소로도 작용한다. 여기서는 발전소의 터빈-발전기용 베어링에 대해서 언급하고자 한다.

  • PDF

Rotordynamic Analysis of a Multistage Turbine Pump Considering the Lomakin Effect (로마킨효과를 고려한 다단터빈펌프의 동특성 해석)

  • 이동환;김영철;최상규;이안성
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.276-281
    • /
    • 1995
  • 마모씨일과 발란스디스크에서의 로마킨효과가 3600rpm에서 운전되는 14단 터빈펌프의 동특성에 미치는 영향을 고찰한 결과 다음과 같은 결론을 얻을 수 있었다. 1. 14단 터빈펌프 시제품 해석을 위한 유한요소 모델링 및 해석결과는 실험적 모드해석을 통하여 5% 이내의 오차로 검증되었다. 2. 마모링 및 밸런스 디스크의 로마킨효과를 고려하였을 때 시제품 펌프의 위험속도는 그렇지 않았을 때에 비하여 1차의 경우 약 50% 상승하나 고차의 경우는 그 영향이 미미하였다. 그런데 1차 위험속도가 운전속도와 밀접한 관련이 있으므로 설계시 로마킨효과는 반드시 고려되어야 한다. 3. 마모링 및 밸런스디스크의 설계변경에 의하여 시제품 펌프의 강성을 변화시킬 경우 위험속도가 크게 변화하는 것으로 나타났다. 이를 이용하면 펌프의 심각한 구조변경 없이도 씨일의 적절한 설계에 의하여 임펠러 깃등의 고조화성분을 포함한 유해한 진동을 회피하는 동특성 설계가 가능하다. 향후 계속 연구사업으로서 씨일의 동특성 해석코드 개발 및 Wet Test를 통하여 본 연구결과를 검증하고 그 결과를 다단 터빈 펌프의 동특성 설게에 적용하여 고압 다단 터빈 펌프의 독자적 개발에 활용코자 한다.

  • PDF

Rotordynamic design of a fuel pump and turbine for a 75 ton liquid rocket engine (75톤급 액체로켓 엔진용 연료펌프/터빈 회전체 동역학 설계)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Yoon, Suk-Hwan;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.201-208
    • /
    • 2007
  • A fuel pump and turbine rotordynamic design is performed for a 75 ton thrust liquid rocket engine. A distance from the rear bearing to the turbine was considered as a design parameter for load distribution of the bearings. Asynchronous eigenvalue analysis was performed as a function of rotating speeds, turbine mass and bearing stiffness to investigate critical speed of the fuel pump and turbine. From the numerical analysis, it is found that the effect of the front bearing stiffness is negligible in the critical speed due to the large mass moment of inertia of the turbine. With the rear bearing stiffness over $2{\times}10^{8}N/m$ and the turbine mass below 20 kg, the critical speed of the fuel pump and turbine in long shaft case is at least 70 % higher than the operating speed 11,000 rpm.

  • PDF

Design of Small-Scale Simulator for Verification of Wind Turbine Conrol (풍력터빈 제어 검증용 축소형 시뮬레이터 설계)

  • Hwang, Jin-Su;Lee, Ho-Chul;Won, Seoung-Young;Chun, Sung-Gu;Lee, Byung-Chul;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.55.1-55.1
    • /
    • 2011
  • 풍력터빈에 적용되는 제어로직에 대한 검증을 실험실 기반에서 검증하기 위해서는 바람 및 터빈에 대한 적절한 모델링이 선행되어야 한다. 특히 피치 및 토크제어에 대한 특성을 검증하기 위해서는 블레이드 공력특성 및 터빈의 동특성에 대한 반영이 필연적이다. 본 논문에서는 풍력터빈 적용 제어로직 검증을 위하여 대상터빈에 대한 스케일링 결과, 바람을 모사하기 위한 구동장치 동작 및 터빈 모사장치에 대한 설계 결과에 대하여 소개하도록 한다.

  • PDF

A Study on Interpolated Step Response Model of Dynamic Matrix Control(DMC) for a Boiler-Turbine System of Fossil Power Plant (계단 응답 모델의 보간을 이용한 화력발전 보일러-터빈 시스템의 동역학 행렬제어(DMC)에 관한 연구)

  • Moon, Un-Chul;Oh, Seok-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.109-115
    • /
    • 2008
  • This paper proposes an adaptive Dynamic Matrix Control (DMC) and its application to boiler-turbine system In a conventional DMC, object system is described as a Step Response Model (SRM). However, a nonlinear system is not effectively described as a single SRM. In this paper, nine SRMs at various operating points are prepared. On-line interpolation is performed at every sampling step to find the suitable SRM. Therefore, the proposed adaptive DMC can consider the nonlinearity of boiler-turbine system. The simulation results show satisfactory results with a wide range operation of the boiler-turbine system.

Investigation on the Strength and Vibration Safety of the Liquid Rocket Turbopump Turbine (액체로켓 터보펌프 구동터빈의 구조 강도 및 진동 안전성에 관한 연구)

  • Jeon,Seong-Min;Kim,Jin-Han;Lee,Dae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.77-84
    • /
    • 2003
  • Structural analyses of a turbine bladed-disk for a liquid rocket turbopump are peformed to investigate the safety level of strength and vibration at design point. Due to the high rotational speed of the turbopump, effects of centrifugal forces are carefully considered in the structural analysis. Thermal load caused by extreme temperature distribution is also considered as an external force applied to turbine bladed-disk. A three dimensional finite element method (FEM) is used for cyclic symmetry structural analyses with the MSC/NASTRAN DMAP Alter. Interblade phase angles are considered to investigate structural dynamic characteristics as a function of rotational speed. Through the numerical analysis, effects of centrifugal and thermal loads on the turbine bladed-disk are examined.

Control strategy of an impulse turbine for oscillating water column wave energy converter under irregular waves (진동 수주형 파력발전 시스템의 최대 전력 추출을 위한 임펄스 터빈의 최대 효율 추종 제어기 설계)

  • Song, Seung-Kwan;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1054-1055
    • /
    • 2015
  • 진동 수주형 파력발전 시스템(oscillating water column wave energy converter)의 효율을 증대할 수 있는 터빈의 최대 효율 추종 제어기를 제안한다. 진동 수주형 파력발전 시스템은 캡처 챔버(capture chamber)와 터빈, 발전기로 구성되어 있으며 발전기 말단에 연결된 저항의 값을 제어 입력으로 삼는다. 본 논문에서는 파력발전 시스템의 캡처 챔버와 터빈의 동역학 모델에 대해 소개하고, 터빈의 최대 효율 추종 제어기의 안정성을 증명하고 이를 JONSWAP 모델의 비규칙 파랑 조건하에서 시뮬레이션 하여 제어기 성능을 입증한다.

  • PDF

Success Run Test for Reliability Demonstration of 1100℃ Gas Turbine Blades (1100℃급 가스터빈 동익의 무고장시험을 통한 HCF 신뢰성 평가)

  • Lee, Dooyoung;Goo, Jaeryang;Kim, Doosoo;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.107-111
    • /
    • 2017
  • The reliability on high cycle fatigue damage mechanism for new blades manufactured by reverse-engineering is demonstrated by success-run test. Turbine blades always experience various dynamic loads in turbine operation, as well as being in resonance condition and forced by fluid-induced vibrations mostly during run-up/down, which may accumulate high cycle damage to the blades. The accidents caused by blade failure especially incur not only a lot of troubles to the machinery but also huge financial losses. Therefore it is necessary to verify the reliability of blades in advance for the safe use. The success run test for the reliability demonstration is designed and performed for the new blades using the technique known as resonant high cycle fatigue testing.

Evaluation of Dynamic Thrust Under Wind Shear in Wind Turbine Below Rated Wind Speed (정격풍속 이하에서 풍력터빈의 윈드쉬어 추력 동하중 개발)

  • Lim, Chae-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.4
    • /
    • pp.407-414
    • /
    • 2016
  • As wind turbines are getting larger in size with multi-MW capacity, the blades are getting longer, over 40 m, and hence the asymmetric loads produced during the rotation of the rotor blades are increasing. Some factors such as wind shear, tower shadow, and turbulence have an effect on the asymmetric loads on the blades. This paper focuses on a method of modeling the dynamic load acting on a blade because of thrust variation under wind shear. A method that uses thrust coefficient is presented. For this purpose, "wind shear coefficient of thrust variation" is defined and introduced. Further, we calculate the values of the "wind shear coefficient of thrust variation" for a 2 MW on-shore wind turbine, and analyze them for speeds below the rated wind speed. Then, we implement a dynamic model that represents the thrust variation under wind shear on a blade, using MATLAB/Simulink. It is shown that it is possible to express thrust variations on three blades under wind shear by using both thrust coefficient and "wind shear coefficient of thrust variation."