국내 호텔 건물의 에너지 부하 모델 (Building Load Models for Hotels in Korea)

  • 박화춘;정모
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.48-57
    • /
    • 2009
  • Energy demands for hotels in Korea are surveyed and statistically analyzed to develop calculation models for a simulation. Daily energy loads of 16 hotels located in Seoul, Busan, Daegu, Inchon, and Daejon are analyzed based on energy log sheets. Detailed hourly loads are field measured for 3 hotels that are carefully selected among the surveyed. One of the salient features for energy consumption by hotels is their weekly periodicity. Relatively large values of deviations are observed for both heat and electricity loads through the country. The mains factors are: location, hotel grade (luxuriousness) and insulation. Detailed quantitative information such are annual average, daily variation, and hourly patterns are provided.

데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안 (Analysis and Improvement of Cooling System for Energy Saving in Data Center Building)

  • 장용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

창의 기울기에 따른 건축물 에너지 소비량 예측 (The Prediction of Energy Consumption by Window Inclination)

  • 조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.27-32
    • /
    • 2011
  • Most of domestic building generally don't have fixed shading devices considering of appearance and aesthetic issues. In this study is suggested that tilt window simultaneously has a role of shading and blocking solar radiation. The tilt window thermal performance is investigated by relation ship between inclination and heating cooling road. As comparing vertical window with $5^{\circ}$ and $7^{\circ}$ of tilt window respectively, the heating load is increased by 3.6% and cooling load is reduced by 8.1% on $5^{\circ}$ tilt window and the heating load is increased by 5.3% and cooling load is reduced by 11.5% on $5^{\circ}$ tilt window. Especially, the total load of alternative tilt window is showed the reduction rate 2.6% and3.6% compared of vertical window. Therefore, the tilt window is possible to role of shading of solar radiation and reduction of heating and cooling load.

전도 시계열 계수를 수치해석으로 구하는 방법 (A Procedure for Computing Conduction Time Series Factors by Numerical Method)

  • 변기홍
    • 한국태양에너지학회 논문집
    • /
    • 제37권5호
    • /
    • pp.77-84
    • /
    • 2017
  • The purpose of this paper is to propose the way of computing conduction time series factors (CTSF) using numerical method. After the accuracy of the numerical solution procedure being verified, the method is applied to the wall type 24 and roof type 14 of ASHARE to find the conduction time series coefficients, so called conduction time series factors. The results agree well with the values presented in the ASHRAE handbook. The method proposed can be easily applied to find unknown CTSF for more complex structures. It provides information about the temperature changes at a given location and time, thus validity of generated CTSF can be checked easily.

기상모델을 이용한 지표면 반사능에 따른 냉방에너지 소비 저감 연구 (A Study on Reduction of Air Conditioning Energy Consumption by Surface Albedo Variation Using Meteorological Model)

  • 안재호
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.16-24
    • /
    • 2010
  • Recently environmental regulations like the Kyoto Protocol, adopted in 1997, required the 5.2% reduction of the greenhouse gas emission in 1990. And 13th General Assembly in 2007, held in Bali of India, have agreed to duty reduction even in developing countries in 2013. Korean government needs the researches on climate change and the strategic programs for greenhouse gas reduction. In this paper Colorado State University Mesoscale Model(CSU-MM) was applied to simulate the relationship between surface albedo and air temperature. Meteorological model simulation in region of Ansan-City, Shiheung-City showed that mean air temperature became lower with the increase of albedo value. Simulated air temperature became lower $-0.16^{\circ}C$ and $-0.66^{\circ}C$ by 5% and 20% increase of albedo values respectively. And cooling energy saving amount in air conditioning process was calculated according to lowered air temperature. The reduction of air temperature resulted the reduction of air conditioning energy in personal house and commercial buildings. The increase of albedo from 5% to 20% resulted the reduction of air conditioning energy from 44,493 MWh/yr to 183,796 MWh/yr. Additionally the reduction of greenhouse gas emission through the energy saving was calculated after IPCC guideline. In terms of greenhouse gas emission $CO_2$ was reduced form -30,414 ton-$CO_2$/yr to -125,638 ton-$CO_2$/yr according to the reduction of electric energy.

박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구 (A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period)

  • 박창영;이건호;윤용상;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구 (A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System)

  • 윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구 (A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System)

  • 이충식;이응직;이철구
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석 (Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter)

  • 김보철;최광환;금종수;김종렬
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.15-24
    • /
    • 1998
  • 태양열 집열기의 열손실은 크게 3가지 즉 상부 열손실, 하부 열손실, 측부 열손실로 대별되나 단열이 양호한 집열기에서는 일반적으로 측면으로의 열손실은 무시한다. 측부 열손실을 제외한 두 열손실 중에서도 상부 열손실은 집열기의 대부분의 열손실을 차지하는 지배적인 요소이다. 따라서 태양열 집열기의 집열 성능을 정확하게 파악하기 위해서는 상부 열손실 계수를 정확하게 계산할 필요가 있다. 본 연구에서 사용한 평판형 태양열 집열기(재생기)는 하계에는 제습 및 냉방을 행하고 동계에는 난방을 행하는 전천후 집열판으로 제작되었다. 따라서 장치의 전환없이 겨울에 난방용으로 사용하였을 경우의 집열 성능을 파악하기 위하여 옥외에서 실험을 하였다. 동계 기간 실험을 통하여 본 집열기의 상부 열손실 계수는 약 $3{\sim}4.5W/m^2^{\circ}C$임을 알 수 있었다. 그리고 집열표면에 선택흡수막을 입혀서 난방용으로 사용하면 주위와의 복사 열손실을 크게 줄일 수 있기 때문에 본 집열기의 집열 성능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

여름철 냉방/제습시스템 중 태양열 온수기를 적용할 수 있는 액체흡수제의 재생성능에 관한 연구(실험계획법에 의한 요인효과 분석에 관하여) (Study on the Regenerating Performance of Liquid Desiccant in the Cooling/Dehumidification System able to use a Solar Water Heater in Summer(On the Analysis of Source Effect by the Design of Experiments))

  • 최광환;김보철;김영진
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2002
  • With the possibility of hot water being able to be used as a heating source in a liquid desiccant system, an experimental apparatus for regeneration of the liquid desiccant was set up and series of experiments were conducted in a climate-controlled chamber. This study was performed to ascertain the influences of experimental factors on regenerating performance and to suggest the optimal combination of factors affecting regeneration rate. Furthermore. in order to figure out the contribution ratio of the factors on regenerating performance, a multi-way factorial design among the design of experiments was adopted. According to experimental results, the most influential factor on regenerating performance was temperature of the liquid desiccant and its contribution ratio was about 79.4%. In addition. the optimal operating combination was as follows; $60^{\circ}C$ of solution temperature, $14\ell$/min of solution flow rate, and 190m3/h of air volume.