• Title/Summary/Keyword: 태양열펌프

검색결과 53건 처리시간 0.028초

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

에틸렌글리콜 혼합액을 사용하고, 태양열을 보조열원으로 하는 이중효용 흡수식 시스템의 난방 특성해석 (Analysis of Thermodynamic Design Data for Heating of Double - Effect Solar Absorption System using LiBr - water and Ethylene Glycol Mixture)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.51-61
    • /
    • 2002
  • Analysis of thermodynamic design data of double effect solar absorption heat pump system for heating has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data. enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture (H2O: CHO ratio 10:1 by mole) by computer simulation. The obtained results, COP and mass flow ratio of the water-lithium bromide-ethylene glycol system, are compared with data for the water-Libr pair solution.

흡수식 2중효용 시스템의 증발기 열원으로 태양열을 이용하는 LiCl 수용액 난방시스템 해석 (Analysis of Thermodynamic Design Data of Double-Effect Absorption System for Heating using LiCl-water for Evaporator Heating Source of Solar Energy)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.39-46
    • /
    • 2004
  • In this paper, thermodynamic design data for heating of double-effect absorption system using LiCl-water for evaporator heating source of sofar energy are investigated for the water-LiCl pair and a comparative study of the water-LiCl pair with the water-LiBr pair is given used for the computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water -LiCl pair than for the water-LiBr pair, and FR is lower for the water-LiCl pair than for the water LiBr pair.

가정용 태양발전 랭킨시스템

  • 한국온돌난방시공협회
    • 보일러설비
    • /
    • 통권71호
    • /
    • pp.59-67
    • /
    • 1999
  • 이 논문에서는 태양발전과 저장을 위한 환경친화적 장치에 대하여 기술하였다. 컴퓨터 모델에 주안점을 두고 시스템의 최적 발전조건을 계산하였는데, 여기에는 작동유체 효율과 태양열 집열판의 크기와 효율 그리고 출력이 포함되어 있다. 영국과 멕시코의 기후조건들이 분석되고, 각 위도에 대한 신뢰 할만한 최근 기상자료가 컴퓨터 수치모사에 사용되었다. 결과를 보면, 연간 출력 4000kW.h를 얻기 위해서, 영국의 경우 시스템 설치에 필요한 집열 면적은 $92m^{\2}$이며, 멕시코의 경우에는 유사 모사조건하에서 동일한 출력을 얻기 위해서는 $48m^{\2}$의 집열면적이 필요하다. 터빈과 이송펌프, 발전기 등의 효율에 민감하여 약간의 효율향상이 있으면 집열 면적을 현저히 감소시킬 수 있다.

  • PDF

온실용 히트펌프 시스템의 폐열을 이용한 고추건조 (Pepper Drying by the Heat Discharged from Heat Pump System in Greenhouse)

  • 윤용철;서원명
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 학술발표논문집
    • /
    • pp.204-208
    • /
    • 1999
  • 농산물의 적정 건조온도는 대상작물에 따라서 다르지만, 건조온도를 적정수준으로 유지하고 건조시간을 단축하기 위하여 기계식 건조가 많이 이용되고 있다. 이것은 건조시간의 단축뿐만 아니라 노동력도 상당히 절약할 수 있는 장점을 가지고 있으나 연료비의 불안정과 자원의 한계성 때문에 태양열을 비롯한 대체 에너지를 이용하는 연구가 꾸준히 이루어지고 있다. (중략)

  • PDF

태양열 온수기 시스템에 적용된 기포펌프의 성능평가에 대한 연구 (A Study on Performance Analysis of the Bubble Pump in Solar Water Heater System)

  • 이광성;이설송;김진화;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2310-2315
    • /
    • 2008
  • In this paper, study on performance analysis of bubble pump on the domestic solar water heater system is presented. Device of this experiment is consisted of bubble pump, solar collector and heat exchanger. At the mean time, this system have attached temperature sensors and pressure sensors at bubble pump. In addition, the flow meter was installed at outlet of heat exchanger. And then result of experimental study, average value of the heat exchange amount in heat exchanger was about 7.9kcal/hr, the maximum value of the heat amount in water tank($0.4m^3$) was 489.7kcal/hr and the maximum value of the mass flow rate in bubble pump was about $0.5{\ell}/min$.

  • PDF

태양열 및 지중열원을 이용한 히트펌프 시스템의 최적이용법에 관한 연구 (Study on the Optimum Design of a Heat Pump System Using Solar and Ground Heat)

  • 남유진
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.509-514
    • /
    • 2012
  • In this research, a heat pump system with a heat source network is suggested which utilizes solar heat and ground heat as heat source for cooling and heating. This paper describes the summary of the suggested system and the results of the annual energy simulation. The heating and cooling loads, the electric consumption and the COP were calculated by TRNSYS 16 and evaluated in the cases of different local conditions and different system compositions. In the results, the superiority of the suggested system has been quantitatively evaluated comparing with the conventional heat pump system using one heat source. Furthermore, it was more significant in cold climate, in which the heating COP was 146% increased compared the air source heat pump system, than it in subtropical climate, 119% increased.

고성능 히트펌프 해석모델 개발 연구 (Development of Analysis Model for High-Performance Heat Pump)

  • 임상식;김기범;박성영
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6053-6059
    • /
    • 2013
  • 히트 펌프는 지열이나 태양열 등의 신재생 에너지를 이용하거나 기타 폐열을 재활용하여 기존의 전기 히팅 난방 시스템들보다 에너지 소비율을 낮출 수 있다는 장점으로 인해 그린 에너지 시스템으로써 주목을 받아 왔다. 고효율 히트펌프 시스템 설계를 위한 연구는 오랫동안 지속되어 왔지만, 각각의 구성요소가 유기적이며, 변화에 유연한 해석모델은 존재하지 않는다. 따라서 본 연구에서는 공기 열 원식 히트 펌프를 AMESim Software를 이용해 구성하였다. 독자적으로 개발한 스크롤 압축기 해석 모델을 히트펌프 시스템에 조합함으로써 효율 향상 방안을 모색하였으며, 실험 데이터를 이용하여 개발한 해석모델을 검증하였다. 실험 데이터와 개발한 해석 모델을 이용하여 예측된 데이터를 비교한 결과 최대 오차가 10% 이내로 두 데이터가 잘 일치하였다. 본 연구에서 개발한 히트펌프 해석모델은 향후 시제품을 개발하고 효율 향상을 위한 연구 등에 유용하게 사용될 것으로 사료된다.

흡수기 도색 여부에 따른 원추형 집광기 집열효율 분석 (Thermal Efficiency Analysis of the Conical Solar Concentrator According to the Black Coating of Absorber)

  • 황성근;나문수;우성재;이주희;이귀현
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.125-125
    • /
    • 2017
  • 본 연구에서 원추형 태양열 집광기의 흡수관 표면의 흑색 도색 여부에 따른 효율분석을 수행하였다. 원추형 집광기 시스템은 열 손실 최소화 및 집광비가 우수한 $45^{\circ}$의 원추각을 갖는 원추형 집광기를 설계 및 제작하였다. 원추형 태양열 집광시스템은 열매체 축열을 위한 온도센서가 내장된 축열조와 태양에너지를 집열시키는 원추형 집광기, 유량측정을 위한 유량계, 열매체의 강제순환을 위한 펌프로 구성되어있다. 또한 지속적인 태양추적을 위해 2축 태양 추적 장치를 설치하였다. 흡수관은 원추형 집광기의 중심부에 설비되었으며, 열매체의 순환을 위해 이중 열교환기 구조로 제작되었다. 흡수관의 길이는 열 손실을 최소화하기 위하여 집광기의 높이와 동일하게 설계하였다. 원추형 집광시스템의 작동유체인 물은 펌프에 의해 흡수관과 축열조를 강제순환 하게되고, 용량이 70L인 축열조에 흡수관으로부터 흡수된 태양 복사열이 저장된다. 원추형 집광시스템의 성능실험은 청명한 날 유량 2L/min, 4L/min, 6L/min에 대해 수행되었으며, 집열효율을 계산하여 비교 및 분석하였다. 흑색으로 도색된 흡수기를 부착한 원추형 집광시스템의 집열효율은 82.25%로 나타났으며, 무 도색 흡수관을 갖는 원추형 집광시스템은 73.26%의 집열효율을 나타내었다. 따라서 본 연구를 통해 흡수관 표면의 흑색 도색이 원추형 집광시스템의 집열효율에 큰 영향을 미친다는 것을 알 수 있었다.

  • PDF

태양열 이용 비프레온계 $CF_3CH_2F$(R-134a)적용 열펌프시스템에 의한 학교교실 난방에 관한 연구(II) (The performance of solar heat pump with non-freon refrigerant $CF_3CH_2F$(R-134a) for school classroom heating[II])

  • 선경호;정현채;김기선
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.3-15
    • /
    • 1997
  • 본 연구는 R-12($CF_2Cl_2F$) 대체냉매인 R-134a($CF_3CH_2F$) 적용 태양열 열펌프시스템에 의하여 학교교실($20{\sim}25$평형)이나 학교 화장실($13{\sim}17$평형)의 난방에 관한 것으로서 대체냉매 적용할 때 시스템의 안정성과 성능에 관해 실험되어졌다. 학교교실 난방을 위한 방법 중에서 온풍난방을 택하여 실험하였는데 대체냉매 적용 실제와 모형시스템의 난방성능을 비교 해석하였다. 이 결과를 근거로 R-22($CHClF_2$)와 그 대체냉매들에 대한 성능을 예측하였다. 서울지방 봄 가을철, 겨울철의 외기 온도에서 실내온도가 $18{\sim}20^{\circ}C,\;23{\sim}25^{\circ}C$로 유지할 수 있도록 설계 제작되었다.

  • PDF